SearcharxivSearch

arXiv subjects

Davide Vaccaro

Publications and source records attributed to Davide Vaccaro.

9 recordsLinked to original sources

System performance of a cryogenic test-bed for the time-division multiplexing readout for NewAthena X-IFU

The X-ray Integral Field Unit (X-IFU) is an instrument of ESA's future NewAthena space observatory, with the goal to provide high-energy resolution ($<$ 4 eV at X-ray energies up to 7 keV) and high-spatial resolution (9") spectroscopic imaging over the X-ray energy range from 200 eV to 12 keV, by means of an array of about 1500 transition-edge sensors (TES) read out via SQUID time-division multiplexing (TDM). A TDM-based laboratory test-bed has been assembled at SRON, hosting an array of $75\times 75\ \upmu$m$^2$ TESs that are read out via 2-column $\times$ 32-row TDM. A system component that is critical to high-performance operation is the wiring harness that connects the room-temperature electronics to the cryogenic readout componentry. We report here on our characterization of such a test-bed, whose harness has a length close to what envisioned for X-IFU, which allowed to achieve a co-added energy resolution at a level of 2.7~eV FWHM at 6~keV via 32-row readout. In addition, we provide an outlook on the integration of TDM readout into the X-IFU Focal-Plane Assembly Development Model.

astro-ph.IM

Simulation and Measurement of Out-of-Band Resonances for the FDM Readout of a TES Bolometer

With applications in cosmology, infrared astronomy and CMB survey, frequency-division multiplexing (FDM) proved to be a viable readout for transition-edge sensors (TES). We investigate the occurrence of out-of-band resonances (OBR) which could constrain the bandwidth of the FDM readout of TES bolometers. The study includes SPICE modeling of the entire setup including the cryogenic harness, LC filters, Superconducting Quantum Interference Device (SQUID) and room-temperature amplifier. Simulation results show that the long harness (for flight model) could cause multiple reflections that generate repetitive spikes in the spectrum. Peaks of the OBR are mainly due to the parasitic capacitances at the input of SQUID. Implementing a low-pass RC circuit (snubber) at the input of the SQUID dampened the OBR. As a result, the first peak only appears around 20 MHz which is a safe margin for the 1 MHz-3.8 MHz FDM in use in the prototype readout. Using a spectrum analyzer and broadband LNAs,we also measured the OBR for the prototype FDM readout in the lab up to 500 MHz. The measurement was conducted at temperatures of 50 mK and 4 K and for various biasing of the DC SQUID. It turns out that OBR are more intense at 50 mK and are caused by the harness impedance mismatch rather than the SQUID. Simulation codes and supporting materials are available at https://github.com/githubamin/LT-Spice-Simulation-of-FDM-readout.

astro-ph.IM

Frequency domain multiplexing readout for large arrays of transition-edge sensors

We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on board the future Athena X-ray telescope. Using Ti/Au TES micro-calorimeters, high-Q LC filters and analog/digital electronics developed at SRON and low-noise two-stage SQUID amplifiers from VTT Finland, we demonstrated feasibility of our FDM readout technology, with the simultaneous readout of 37 pixels with an energy resolution at of 2.23 eV at an energy of 6 keV. We finally outline our plans for further scaling up and improving our technology.

astro-ph.IM

Performance of the SRON Ti/Au Transition Edge Sensor X-ray Calorimeters

In the early 2030s, ESAs new X-ray observatory, Athena, is scheduled to be launched. It will carry two main instruments, one of which is the X-ray Integral Field Unit (X-IFU), an X-ray imaging spectrometer, which will consist of an array of several thousand transition-edge sensors (TESs) with a proposed energy resolution of 2.5 eV for photon energies up to 7 keV. At SRON we develop the backup TES array based on Ti/Au bilayers with a transition temperature just below 100 mK. In this contribution we will give a broad overview of the properties and capabilities of these state-of-the-art detectors. Over the years we have fabricated and studied a large number of detectors with various geometries, providing us with a good understanding of how to precisely control the properties of our detectors. We are able to accurately vary the most important detector properties, such as the normal resistance, thermal conductance and critical temperature. This allows us to finely tune our detectors to meet the demands of various applications. The detectors have demonstrated excellent energy resolutions of below 1.8 eV for 5.9 keV X-rays. By tuning the properties of the devices, they can be optimally matched to various read-out schemes using both AC and DC biasing. The next step is to increase the size of our TES arrays from our current kilo-pixel arrays towards the full-sized array for X-IFU.

astro-ph.IM

Susceptibility study of TES micro-calorimeters for X-ray spectroscopy under FDM readout

We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass filter and AC biased with an independent carrier at MHz range. Using TES arrays, cold readout circuitry and warm electronics fabricated at SRON and SQUIDs produced at VTT Finland, we characterize the sensitivity of the detectors to bias voltage, bath temperature and magnetic field. We compare our results with the requirements for the Athena X-IFU instrument, showing the compliance of the measured sensitivities. We find in particular that FDM is intrinsically insensitive to the magnetic field because of TES design and AC readout.

astro-ph.IM

Mitigation of the Magnetic Field Susceptibility of Transition Edge Sensors using a Superconducting Groundplane

Transition edge sensor (TES) microcalorimeters and bolometers are used for a variety of applications. The sensors are based on the steep temperature-dependent resistance of the normal-to-superconducting transition, and are thus intrinsically sensitive to magnetic fields. Conventionally the detectors are shielded from stray magnetic fields using external magnetic shields. However, in particular for applications with strict limits on the available space and mass of an instrument, external magnetic shields might not be enough to obtain the required shielding factors or field homogeneity. Additionally, these shields are only effective for magnetic fields generated external to the TES array, and are ineffective to mitigate the impact of internally generated magnetic fields. Here we present an alternative shielding method based on a superconducting groundplane deposited directly on the backside of the silicon nitride membrane on which the TESs are located. We demonstrate that this local shielding for external magnetic fields has a shielding factor of at the least ~ 75, and is also effective at reducing internal self-induced magnetic fields, as demonstrated by measurements and simulation of the eddy current losses in our AC biased detectors. Measurements of 5.9 keV X-ray photons show that our shielded detectors have a high resilience to external magnetic fields, showing no degradation of the energy resolution or shifts of the energy scale calibration for fields of several microTesla, values higher than expected in typical real-world applications.

astro-ph.IM

Thermal crosstalk of X-ray transition-edge sensor micro-calorimeters under frequency domain multiplexing readout

We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a 8$\times$8 and a 32$\times$32 "kilo-pixel" uniform array. The amount of crosstalk is evaluated as the ratio between the averaged crosstalk signal and the X-ray pulse amplitudes. The crosstalk ratios (CR) for our detectors are compliant with the requirements for future X-ray space missions, such as Athena X-IFU (CR$< 10^{-3}$ for first-neighbour pixels): we measured a nearest-neighbour thermal crosstalk ratio at a level of $10^{-4}$, with a highest crosstalk ratio of $4\times 10^{-4}$ for the kilo-pixel array (worst case, center of array) and $1\times 10^{-4}$ for the 8$\times$8 array, with a margin of improvement achievable by optimizing the Cu metallization and the width of the Si supporting structures (muntins) in the backside of the TES array chip. Based on the measured crosstalk ratios, we have estimated the impact on the spectral resolution by means of noise equivalent power (NEP) considerations and a Monte Carlo simulation, finding an average degradation in quadrature of less than 40~meV, compliant with the < 0.2~eV requirement for Athena X-IFU.

astro-ph.IM

Frequency Shift Algorithm: Design of a Baseband Phase Locked Loop for Frequency-Domain Multiplexing Readout of X-ray Transition-Edge Sensor Microcalorimeters

The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out system for kilopixel arrays of such TESs. Each TES is voltage biased at a specific frequency in the range 1 to 5 MHz. Isolation between the individual pixels is obtained through very narrow-band (high-Q) lithographic LC resonators. To prevent energy resolution degradation due to intermodulation line noise, the bias frequencies are distributed on a regular grid. The requirements on the accuracy of the LC resonance frequency are very high. The deviation of the resonance frequencies due to production tolerances is significant with respect to the bandwidth, and a controller is necessary to compensate for the LC series impedance. We present two such controllers: a simple orthogonal proportional-integrating (PI) controller and a more complex impedance estimator. Both controllers operate in baseband and try to make the TES current in-phase with the bias voltage, effectively operating as phase-locked loops (PLL). They allow off-LC-resonance operation of the TES pixels, while preserving TES thermal response and energy resolution. Extensive experimental results -- published in a companion paper recently -- with the proposed methods, show that these controllers allow the preservation of single pixel energy resolution in multiplexed operation.

physics.ins-det

Single pixel performance of a 32$\times$32 Ti/Au TES array with broadband X-ray spectra

We are developing a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the range 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$α$ at 5.9 keV) and a Modulated X-ray Source (MXS, providing Cr-K$α$ at 5.4 keV and Cu-K$α$ at 8.0 keV). First, we report the procedure used to perform the detector energy scale calibration, usually achieving a calibration accuracy better than $\sim$ 0.5 eV in the 5.4 - 8.9 keV energy range. Then, we present the measured energy resolution at the different energies (best single pixel performance: $Δ$E$_{FWHM}$ = 2.40 $\pm$ 0.09 eV @ 5.4 keV; 2.53 $\pm$ 0.10 eV @ 5.9 keV; 2.78 $\pm$ 0.16 eV @ 8.0 keV), investigating also the performance dependency from the pixel bias frequency and the count rate. Thanks to long background measurements ($\sim$ 1 day), we finally detected also the Al-K$α$ line at 1.5 keV, generated by fluorescence inside the experimental setup. We analyzed this line to obtain a first assessment of the single-pixel performance also at low energy ($Δ$E$_{FWHM}$ = 1.91 eV $\pm$ 0.21 eV @ 1.5 keV), and to evaluate the linearity of the detector response in a large energy band (1.5 - 8.9 keV).

astro-ph.IM