SearcharxivSearch

arXiv subjects

E. -S. Kim

Publications and source records attributed to E. -S. Kim.

5 recordsLinked to original sources

Monitoring antiproton numbers with a CMOS detector in a dense-track environment

The production of antihydrogen by the GBAR experiment at AD/ELENA requires good knowledge of the number of incident keV antiprotons, which can be problematic. We have used a commercial CMOS digital camera mounted around the experimental vacuum chamber to determine antiproton numbers from ionising particles created in the annihilation process on the surface of microchannel plate detectors which are used for beam imaging. We show that the multiplicity of emerging charged particles is as expected for individual annihilations of antiprotons with nucleons at rest, taking into account the surrounding material budget. Most of those particles are in the minimal ionising regime, but can be detected with nearly 100% efficiency in the CMOS pixel detector, while due to the thin depletion layer the device is insensitive to background gammas. Thanks to the high granularity and small pixel size millions of antiproton annihilations can be reconstructed in a dense tracking environment over a large dynamic range with good resolution. From cluster length studies of non perpendicular tracks the thickness of the depletion zone and effective detection area was estimated. The cluster length also allows for a monitoring of track angles. Antiproton numbers are determined from the number of reconstructed clusters in the CMOS sensor by means of the covered solid angle relative to a calibration measurements with well known beam intensities at the most upstream location of the GBAR apparatus. Material effects on the emerging annihilation products were estimated by Monte Carlo (Geant4) calculations, while annihilation artefacts on the complex surface of a microchannel plate are cancelled out in this approach. This method minimises largely systematic uncertainties, leading to a final error of roughly 10% for the reconstruction of absolute antiproton numbers.

physics.ins-det

A determination of the backscattering probability of low-energy antiprotons

It is commonly assumed that antiprotons impinging on a material surface annihilate promptly with the nuclei of the material. However, at kinetic energies of a few keV, this assumption may not hold. As with low-energy protons, electrons or positrons that can be reflected from a target, they may undergo large-angle Coulomb scattering before annihilation occurs, thereby appearing to be "backscattered" from the material surface. This backscattering fraction, largely unknown, is a crucial ingredient to the determination of the production cross-section of antihydrogen atoms in the GBAR experiment. This paper presents a determination of the probability that 4 and 6 keV antiprotons backscatter on the surface of a Micro-Channel Plate detector used for beam imaging at GBAR. No evidence for backscattering has been found and an upper limit of 14% at 68% confidence level has been set on this probability. The impact of backscattering on the determination of the number of antiprotons that participate in antihydrogen production in GBAR is also addressed.

hep-ex

The Development of Low-Q Cavity Type Beam Position Monitor with a Position Resolution of Nanometer for Future Colliders

The nano-meter beam size in future linear colliders requires very high resolution beam position monitor since higher resolution allows more accurate position measurement in the interaction point. We developed and tested a low-Q C-band beam position monitor with position resolution of nanometer. The C-band BPM was tested for the fast beam feedback system at the interaction point of ATF2 in KEK, in which C-band beam position monitor is called to IPBPM (Interaction Point Beam Position Monitor). The average position resolution of the developed IPBPMs was measured to be 10.1 nm at a nominal beam charge of $87\%$ of ATF2. From the measured beam position resolution, we can expect beam position resolution of around 8.8 nm and 4.4 nm with nominal ATF2 and ILC beam charge conditions, respectively, in which the position resolution is below the vertical beam size in ILC. In this paper, we describe the development of the IPBPM and the beam test results at the nanometer level in beam position resolution

physics.acc-ph

Cavity beam position monitor system for the Accelerator Test Facility 2

The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1 m for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.

physics.acc-ph

Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

physics.acc-ph