Searcharxiv⌕ Search

arXiv subjects

E. Czerwiński

Publications and source records attributed to E. Czerwiński.

At least 73 records · Page 4Linked to original sources

Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector

In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence of physics phenomena beyond the Standard Model. Previous measurements resulted in violation amplitude parameters for CP and CPT symmetries consistent with zero, with an uncertainty of about 10-3. The J-PET detector allows to determine those values with better precision thanks to a unique time and angular esolution combined with a high geometrical acceptance. Achieving the aforementioned is possible due to application of polymer scintillators instead of crystals as detectors of annihilation quanta.

physics.ins-det↗

Studies of unicellular micro-organisms Saccharomyces cerevisiae by means of Positron Annihilation Lifetime Spectroscopy

Results of Positron Annihilation Lifetime Spectroscopy (PALS) and microscopic studies on simple microorganisms: brewing yeasts are presented. Lifetime of ortho - positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer lived component) for lyophilised and aqueous yeasts, respectively. Also hygroscopicity of yeasts in time was examined, allowing to check how water - the main component of the cell - affects PALS parameters, thus lifetime of o-Ps were found to change from 1.2 to 1.4 ns (shorter lived component) for the dried yeasts. The time sufficient to hydrate the cells was found below 10 hours. In the presence of liquid water an indication of reorganization of yeast in the molecular scale was observed. Microscopic images of the lyophilised, dried and wet yeasts with best possible resolution were obtained using Inverted Microscopy (IM) and Environmental Scanning Electron Microscopy (ESEM) methods. As a result visible changes to the surface of the cell membrane were observed in ESEM images.

q-bio.OT↗

Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance

The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a dedicated sampling front-end electronics which enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity we use the Mahalanobis distance. The achievable position and time-resolution depends on number and values of the threshold levels at which the signal is sampled. A reconstruction method, as well as preliminary results are presented and discussed.

physics.ins-det↗

PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix

The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.

physics.ins-det↗

Processing optimization with parallel computing for the J-PET tomography scanner

The Jagiellonian-PET (J-PET) collaboration is developing a prototype TOF-PET detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast, FPGA-based front-end electronics and the data acquisition system, as well as, low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in case of a large acceptance detector, which works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.

physics.ins-det↗

Hit time and hit position reconstruction in the J-PET detector based on a library of averaged model signals

In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors amplitude and shape of registered signals depends strongly on the position where particle hit the detector. The reconstruction is based on determination of the degree of similarity between measured and averaged signals stored in a library for a set of well-defined positions along the scintillator. Preliminary results of validation of the introduced method with experimental data obtained by means of the double strip prototype of the J-PET detector are presented.

physics.ins-det↗

Analysis framework for the J-PET scanner

J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The Framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.

physics.ins-det↗

A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter

For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the anthracene light output. There is a potential to improve this value in the future by the optimization of the additives concentrations.

physics.ins-det↗

A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals

A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of well-defined positions of scintillation points. The hit position is reconstructed as the one corresponding to the signal from the library which is most similar to the measurement signal. The time of the interaction is determined as a relative time between the measured signal and the most similar one in the library. A degree of similarity of measured and model signals is defined as the distance between points representing the measurement- and model-signal in the multi-dimensional measurement space. Novelty of the method lies also in the proposed way of synchronization of model signals enabling direct determination of the difference between time-of-flights (TOF) of annihilation quanta from the annihilation point to the detectors. The introduced method was validated using experimental data obtained by means of the double strip prototype of the J-PET detector and $^{22}$Na sodium isotope as a source of annihilation gamma quanta.The detector was built out from plastic scintillator strips with dimensions of 5 mm x 19 mm x 300 mm, optically connected at both sides to photomultipliers,from which signals were sampled by means of the Serial Data Analyzer.Using the introduced method, the spatial and TOF resolution of about 1.3 cm ($σ$) and 125 ps ($σ$) were established, respectively.

physics.ins-det↗

Recent KLOE results on kaon physics

A short review of two measurements recently published by KLOE/KLOE-2 collaborations is presented. Namely the most stringent limits of the CPT-violating parameters Delta a_mu for neutral kaons, and the absolute branching ratio of K+ --> pi+pi-pi+(gamma) decay. In addition a discussion of starting KLOE-2 project is performed.

nucl-ex↗

Close to threshold eta' meson production in proton-proton collisions at COSY-11

Intensive quest for the eta and eta' bound states is currently ongoing at both theoretical and experimental levels e.g. at COSY, ELSA, GSI, JINR, JPARC, LPI, and MAMI. These studies were already supported by data provided by the COSY-11 collaboration including determination of the total width of the eta' meson. In addition, the first rough estimation of the eta'-N interaction from the excitation function of the cross section for the pp-->pp eta' reaction was also performed. Recent precise measurement in this field from the COSY-11 experiment allows to summarize results on the eta' meson production cross section in proton-proton collisions at COSY-11.

nucl-ex↗

Charge Symmetry Breaking in dd->4Heπ0 with WASA-at-COSY

Charge symmetry breaking (CSB) observables are a suitable experimental tool to examine effects induced by quark masses on the nuclear level. Previous high precision data from TRIUMF and IUCF are currently used to develop a consistent description of CSB within the framework of chiral perturbation theory. In this work the experimental studies on the reaction dd->4Heπ0 have been extended towards higher excess energies in order to provide information on the contribution of p-waves in the final state. For this, an exclusive measurement has been carried out at a beam momentum of p=1.2 GeV/c using the WASA-at-COSY facility. The total cross section amounts to sigma(tot) = (118 +- 18(stat) +- 13(sys) +- 8(ext)) pb and first data on the differential cross section are consistent with s-wave pion production.

nucl-ex↗

Measurement of the $np \to npπ^0π^0$ Reaction in Search for the Recently Observed $d^*(2380)$ Resonance

Exclusive measurements of the quasi-free $np \to npπ^0π^0$ reaction have been performed by means of $dp$ collisions at $T_d$ = 2.27 GeV using the WASA detector setup at COSY. Total and differential cross sections have been obtained covering the energy region $\sqrt s$ = (2.35 - 2.46) GeV, which includes the region of the ABC effect and its associated $d^*(2380)$ resonance. Adding the $d^*$ resonance amplitude to that for the conventional processes leads to a reasonable description of the data. The observed resonance effect in the total cross section is in agreement with the predictions of Fäldt and Wilkin as well Albadajedo and Oset. The ABC effect, {\it i.e.} the low-mass enhancement in the $π^0π^0$-invariant mass spectrum, is found to be very modest - if present at all, which might pose a problem to some of its interpretations.

nucl-ex↗

Test of a single module of the J-PET scanner based on plastic scintillators

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to sigma(E)/E = 0.044/sqrt(E[MeV]) and corresponds to the sigma(E)/E of 7.5% at the Compton edge.

physics.ins-det↗

ABC Effect and Resonance Structure in the Double-Pionic Fusion to $^3$He

Exclusive and kinematically complete measurements of the double pionic fusion to $^3$He have been performed in the energy region of the so-called ABC effect, which denotes a pronounced low-mass enhancement in the $ππ$-invariant mass spectrum. The experiments were carried out with the WASA detector setup at COSY. Similar to the observations in the basic $pn \to d π^0π^0$ reaction and in the $dd \to ^4$He$π^0π^0$ reaction, the data reveal a correlation between the ABC effect and a resonance-like energy dependence in the total cross section. Differential cross sections are well described by the hypothesis of $d^*$ resonance formation during the reaction process in addition to the conventional $t$-channel $ΔΔ$ mechanism. The deduced $d^*$ resonance width can be understood from collision broadening due to Fermi motion of the nucleons in initial and final nuclei.

nucl-ex↗

Neutron-Proton Scattering in the Context of the $d^*$(2380) Resonance

New data on quasifree polarized neutron-proton scattering, in the region of the recently observed $d^*$ resonance structure, have been obtained by exclusive and kinematically complete high-statistics measurements with WASA at COSY. This paper details the determination of the beam polarization, checks of the quasifree character of the scattering process, on all obtained $A_y$ angular distributions and on the new partial-wave analysis, which includes the new data producing a resonance pole in the $^3D_3$-$^3G_3$ coupled partial waves at ($2380\pm10 - i40\pm5$) MeV -- in accordance with the $d^*$ dibaryon resonance hypothesis. The effect of the new partial-wave solution on the description of total and differential cross section data as well as specific combinations of spin-correlation and spin-transfer observables available from COSY-ANKE measurements at $T_d$ = 2.27 GeV is discussed.

nucl-ex↗