Cross section ratio and angular distributions of the reaction p + d -> 3He + eta at 48.8 MeV and 59.8 MeV excess energy

We present new data for angular distributions and on the cross section ratio of the p + d -> 3He + eta reaction at excess energies of Q = 48.8 MeV and Q = 59.8 MeV. The data have been obtained at the WASA-at-COSY experiment (Forschungszentrum Jülich) using a proton beam and a deuterium pellet target. While the shape of obtained angular distributions show only a slow variation with the energy, the new results indicate a distinct and unexpected total cross section fluctuation between Q = 20 MeV and Q = 60 MeV, which might indicate the variation of the production mechanism within this energy interval.

nucl-ex↗

Study of the N N eta' production with COSY-11

We describe a new high precision measurement of the production cross-section for the eta' meson in proton-proton collisions for five beam momenta at low access energy region Q conducted at the COSY-11 detection system together with an updated results of all other previous measurements of cross-section for (pp-->pp eta') at COSY-11.

nucl-ex↗

Investigation of the dd -> 3He n π0 reaction with the FZ Jülich WASA-at-COSY facility

An exclusive measurement of the dd -> 3He n π0 reaction was carried at a beam momentum of p = 1.2 GeV/c using the WASA-at-COSY facility. For the first time data on the total cross section as well as differential distributions were obtained. The data are described with a phenomenological approach based on a combination of a quasi-free model and a partial wave expansion for three-body reaction. The total cross section is found to be σ(tot) = (2.89 +- 0.01(stat) +- 0.06(sys) +- 0.29(norm)) μb. The contribution of the quasi-free processes (with the neutron being target or beam spectator) accounts for 38% of the total cross section and dominates the differential distributions in specific regions of the phase space. The remaining part of the cross section can be described within a partial wave decomposition indicating the significance of p-wave contributions in the final state.

nucl-ex↗

A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays

All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present methods and it is well suited for newly developed TOF-PET scanners with a large longitudinal field of view. The method enables also monitoring of the quality of the scintillator materials and in general allows for the continuous quality assurance of the PET detector performance.

physics.ins-det↗

J-PET analysis framework for the prototype TOF-PET detector

Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics of the Jagiellonian University. This software is based on the ROOT package used in many particle physics experiments.

physics.ins-det↗

Determination of the map of efficiency of the J-PET detector with the GATE package

A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.

physics.ins-det↗

Database and data structure for the novel TOF-PET detector developed for J-PET project

The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: registration process of the gamma quanta emitted from positron-electron annihilation, Front-End Electronic (FEE) structure and required input information for the image reconstruction. In addition, the system database fulfills possible demands of the evolving J-PET project.

physics.ins-det↗

π^0 π^0 Production in Proton-Proton Collisions at Tp=1.4 GeV

The reaction pp->pppi0pi0 has been investigated at a beam energy of 1.4 GeV using the WASA-at-COSY facility. The total cross section is found to be (324 +- 21_systematic +- 58_normalization) mub. In order to to study the production mechanism, differential kinematical distributions have been evaluated. The differential distributions indicate that both initial state protons are excited into intermediate Delta(1232) resonances, each decaying into a proton and a single pion, thereby producing the pion pair in the final state. No significant contribution of the Roper resonance N*(1440) via its decay into a proton and two pions is found

hep-ex↗

Computing support for advanced medical data analysis and imaging

We discuss computing issues for data analysis and image reconstruction of PET-TOF medical scanner or other medical scanning devices producing large volumes of data. Service architecture based on the grid and cloud concepts for distributed processing is proposed and critically discussed.

physics.comp-ph↗

Calibration of photomultipliers gain used in the J-PET detector

Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we describe single photoelectron method used for photomultipliers calibration applied for J-PET scanner, a novel PET detector being developed at the Jagiellonian University. Description of calibration method, an example of calibration curve and gain of few R4998 Hamamatsu photomultipliers are presented.

physics.ins-det↗

Simulations of gamma quanta scattering in a single module of the J-PET detector

This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the scintillator strip with the cross section of 5 mm x 19 mm. Obtained results indicate that secondary interactions occur only in the case of about 8% of events and out of them only 25$\%$ take place in the distance larger than 0.5 cm from the primary interaction. It was also established that light signals produced at primary and secondary interactions overlap with the delay which distribution is characterized by FWHM of about 40 ps.

physics.ins-det↗

Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators

A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presently used Positron Emission Tomography scanners.

physics.ins-det↗

A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography

This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic components used in Positron Emission Tomography (PET). Described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics and also makes more compact final design. Furthermore, it allows to measure time when analog signals cross a reference voltage at different threshold levels with a very high precision of $\sim$ 10ps (rms) and thus enables sampling of signals in a voltage domain.

physics.ins-det↗

Measurement of the $pn \to ppπ^0π^-$ Reaction in Search for the Recently Observed Resonance Structure in $dπ^0π^0$ and $dπ^+π^-$ systems

Exclusive measurements of the quasi-free $pn \to ppπ^0π^-$ reaction have been performed by means of $pd$ collisions at $T_p$ = 1.2 GeV using the WASA detector setup at COSY. Total and differential cross sections have been obtained covering the energy region $\sqrt s$ = (2.35 - 2.46) GeV, which includes the region of the ABC effect and its associated resonance structure. No ABC effect, {\it i.e.} low-mass enhancement is found in the $π^0π^-$-invariant mass spectrum -- in agreement with the constraint from Bose statistics that the isovector pion pair can not be in relative s-wave. At the upper end of the covered energy region $t$-channel processes for Roper, $Δ(1600)$ and $ΔΔ$ excitations provide a reasonable description of the data, but at low energies the measured cross sections are much larger than predicted by such processes. Adding a resonance amplitude for the resonance at $m$=~2.37 GeV with $Γ$ =~70 MeV and $I(J^P)=~0(3^+)$ observed recently in $pn \to dπ^0π^0$ and $pn \to dπ^+π^-$ reactions leads to an agreement with the data also at low energies.

nucl-ex↗

System Response Kernel Calculation for List-mode Reconstruction in Strip PET Detector

Reconstruction of the image in Positron Emission Tomographs (PET) requires the knowledge of the system response kernel which describes the contribution of each pixel (voxel) to each tube of response (TOR). This is especially important in list-mode reconstruction systems, where an efficient analytical approximation of such function is required. In this contribution, we present a derivation of the system response kernel for a novel 2D strip PET.

physics.med-ph↗

Search for a dark photon in the $π^0 \to e^+e^-γ$ decay

The presently world largest data sample of pi0 --> gamma e+e- decays containing nearly 5E5 events was collected using the WASA detector at COSY. A search for a dark photon U produced in the pi0 --> gamma U --> gamma e+e- decay from the pp-->ppπ^0 reaction was carried out. An upper limit on the square of the U-gamma mixing strength parameter epsilon^2 of 5e-6 at 90% CL was obtained for the mass range 20 MeV <M_U< 100 MeV. This result together with other recent experimental limits significantly reduces the M_U vs. ε^2 parameter space preferred by the measured value of the muon anomalous magnetic moment.

hep-ex↗