Searcharxiv⌕ Search

arXiv subjects

E. Previtali

Publications and source records attributed to E. Previtali.

At least 37 records · Page 2Linked to original sources

Search for fractionally charged particles with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using the first tonne-year of CUORE's exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various Standard Model extensions and would have suppressed interactions with matter. No excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges between $e/24-e/5$ at 90\% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale sub-Kelvin detectors to diverse signatures of new physics.

hep-ex↗

Distillation and Stripping purification plants for JUNO liquid scintillator

The optical and radiochemical purification of the scintillating liquid, which will fill the central detector of the JUNO experiment, plays a crucial role in achieving its scientific goals. Given its gigantic mass and dimensions and an unprecedented target value of about 3% @ 1 MeV in energy resolution, JUNO has set severe requirements on the parameters of its scintillator, such as attenuation length (Lat>20 m at 430 nm), transparency, light yield, and content of radioactive contaminants (238U,232Th<10-15 g/g). To accomplish these needs, the scintillator will be processed using several purification methods, including distillation in partial vacuum and gas stripping, which are performed in two large scale plants installed at the JUNO site. In this paper, layout, operating principles, and technical aspects which have driven the design and construction of the distil- lation and gas stripping plants are reviewed. The distillation is effective in enhancing the optical properties and removing heavy radio-impurities (238U,232Th, 40K), while the stripping process exploits pure water steam and high-purity nitrogen to extract gaseous contaminants (222Rn, 39Ar, 85Kr, O2) from the scintillator. The plant operating parameters have been tuned during the recent com- missioning phase at the JUNO site and several QA/QC measurements and tests have been performed to evaluate the performances of the plants. Some preliminary results on the efficiency of these purification processes will be shown.

physics.ins-det↗

Refractive index in the JUNO liquid scintillator

In the field of rare event physics, it is common to have huge masses of organic liquid scintillator as detection medium. In particular, they are widely used to study neutrino properties or astrophysical neutrinos. Thanks to its safety properties (such as low toxicity and high flash point) and easy scalability, linear alkyl benzene is the most common solvent used to produce liquid scintillators for large mass experiments. The knowledge of the refractive index is a pivotal point to understand the detector response, as this quantity (and its wavelength dependence) affects the Cherenkov radiation and photon propagation in the medium. In this paper, we report the measurement of the refractive index of the JUNO liquid scintillator between 260-1064 nm performed with two different methods (an ellipsometer and a refractometer), with a sub percent level precision. In addition, we used an interferometer to measure the group velocity in the JUNO liquid scintillator and verify the expected value derived from the refractive index measurements.

physics.ins-det↗

Data-driven background model for the CUORE experiment

We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg$^{-1}$ and 0.1 nBq cm$^{-2}$, respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.

nucl-ex↗

Measurement of the 2$νββ$ Decay Half-Life of Se-82 with the Global CUPID-0 Background Model

We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 8.82~kg$\times$yr of $^{82}$Se. We identify with improved precision the background sources within the 3 MeV energy region, where neutrinoless double $β$-decay of $^{82}$Se and $^{100}$Mo is expected, making more solid the foundations for the background budget of the next-generation CUPID experiment. Relying on the excellent data reconstruction, we measure the two-neutrino double $β$-decay half-life of $^{82}$Se with unprecedented accuracy: $T_{1/2}^{2ν} = [8.69 \pm 0.05 \textrm{(stat.)}~^{+0.09}_{-0.06} \textrm{(syst.)}] \times 10^{19}~\textrm{yr}$.

nucl-ex↗

Measurement of the $2νββ$ decay rate and spectral shape of $^{100}$Mo from the CUPID-Mo experiment

Neutrinoless double beta decay ($0νββ$) is a yet unobserved nuclear process which would demonstrate Lepton Number violation, a clear evidence of beyond Standard Model physics. The process two neutrino double beta decay ($2νββ)$ is allowed by the Standard Model and has been measured in numerous experiments. In this letter, we report a measurement of $2νββ$ decay half-life of $^{100}$Mo to the ground state of $^{100}$Ru of $(7.07~\pm~0.02~\text{(stat.)}~\pm~0.11~\text{(syst.)})~\times~10^{18}$~yr by the CUPID-Mo experiment. With a relative precision of $\pm~1.6$ \% this is the most precise measurement to date of a $2νββ$ decay rate in $^{100}$Mo. In addition, we constrain higher-order corrections to the spectral shape which provides complementary nuclear structure information. We report a novel measurement of the shape factor $ξ_{3,1}=0.45~\pm 0.03~\text{(stat.)} \ \pm 0.05 \ \text{(syst.)}$, which is compared to theoretical predictions for different nuclear models. We also extract the first value for the effective axial vector coupling constant obtained from a spectral shape study of $2νββ$ decay.

nucl-ex↗

The background model of the CUPID-Mo $0νββ$ experiment

CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation $0νββ$ decay experiment, CUPID. It consisted of an array of 20 enriched Li$_{2}$$ ^{100}$MoO$_4$ bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform and validate the background prediction for CUPID. In this paper, we present a detailed model of the CUPID-Mo backgrounds. This model is able to describe well the features of the experimental data and enables studies of the $2νββ$ decay and other processes with high precision. We also measure the radio-purity of the Li$_{2}$$^{100}$MoO$_4$ crystals which are found to be sufficient for the CUPID goals. Finally, we also obtain a background index in the region of interest of 3.7$^{+0.9}_{-0.8}$(stat)$^{+1.5}_{-0.7}$(syst)$\times10^{-3}$counts/$Δ$E$_{FWHM}$/mol$_{iso}$/yr, the lowest in a bolometric $0νββ$ decay experiment.

hep-ex↗

Final results on the $0νββ$ decay half-life limit of $^{100}$Mo from the CUPID-Mo experiment

The CUPID-Mo experiment to search for 0$νββ$ decay in $^{100}$Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0$νββ$ decay experiment. CUPID-Mo was comprised of 20 enriched Li$_2$$^{100}$MoO$_4$ scintillating calorimeters, each with a mass of $\sim$ 0.2 kg, operated at $\sim$20 mK. We present here the final analysis with the full exposure of CUPID-Mo ($^{100}$Mo exposure of 1.47 kg$\times$yr) used to search for lepton number violation via 0$νββ$ decay. We report on various analysis improvements since the previous result on a subset of data, reprocessing all data with these new techniques. We observe zero events in the region of interest and set a new limit on the $^{100}$Mo 0$νββ$ decay half-life of $T^{0ν}_{1/2} > 1.8 \times 10^{24}$ year (stat.+syst.) at 90% CI. Under the light Majorana neutrino exchange mechanism this corresponds to an effective Majorana neutrino mass of $\left < (0.28$--$0.49)$ eV, dependent upon the nuclear matrix element utilized.

nucl-ex↗

Search for Majoron-like particles with CUPID-0

We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the existence of a Majoron-like boson coupling to the neutrino. The energy spectra arising from the emission of such bosons in the neutrinoless double $β$ decay have spectral indices $n=$ 1, 2, 3 or 7. We found no evidence of any of these decay modes, setting a lower limit (90% of credibility interval) on the half-life of 1.2 $\times$ 10$^{23}$ yr in the case of $n=$ 1, 3.8 $\times$ 10$^{22}$ yr for $n=$ 2, 1.4 $\times$ 10$^{22}$ yr for $n=$ 3 and 2.2 $\times$ 10$^{21}$ yr for $n=$ 7. These are the best limits on the $0νββχ_0$ half-life of the $^{82}$Se, and demonstrate the potentiality of the CUPID-0 technology in this field.

hep-ex↗

An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

physics.ins-det↗

New measurement of double beta decays of $^{100}$Mo to excited states of $^{100}$Ru with the CUPID-Mo experiment

The CUPID-Mo experiment, located at Laboratoire Souterrain de Modane (France), was a demonstrator experiment for CUPID. It consisted of an array of 20 Li$_2^{100}$MoO$_4$ (LMO) calorimeters each equipped with a Ge light detector (LD) for particle identification. In this work, we present the result of a search for two-neutrino and neutrinoless double beta decays of $^{100}$Mo to the first 0$^+$ and $2^+$ excited states of $^{100}$Ru using the full CUPID-Mo exposure (2.71 kg$\times$yr of LMO). We measure the half-life of $2νββ$ decay to the $0^{+}_1$ state as $T_{1/2}^{2ν\rightarrow 0_1^+}=7.5\pm 0.8 \ \text{(stat.)} \ ^{+ 0.4}_{-0.3} \ \text{(syst.)} )\times 10^{20} \ \mathrm{yr}$. The bolometric technique enables measurement of the electron energies as well as the gamma rays from nuclear de-excitation and this allows us to set new limits on the two-neutrino decay to the $2_1^+$ state of $T^{2ν\rightarrow 2_1^+}_{1/2}>4.4\times 10^{21} \ \mathrm{yr} \ \text{(90 % c.i.)}$ and on the neutrinoless modes of $T_{1/2}^{0ν\rightarrow 2_1^+}>2.1\times10^{23} \ \mathrm{yr}\ \text{(90 % c.i.)}$, $T_{1/2}^{0ν\rightarrow 0_1^+}>1.2\times10^{23} \ \mathrm{yr}\ \text{(90 % c.i.)}$. Information on the electrons spectral shape is obtained which allows us to make the first comparison of the single state (SSD) and higher state (HSD) $2νββ$ decay models for the $0_1^+$ excited state of $^{100}$Ru.

nucl-ex↗

Search for Neutrinoless $β^+EC$ Decay of $^{120}$Te with CUORE

CUORE is a large scale cryogenic experiment searching for neutrinoless double beta decay ($0νββ$) in $^{130}$Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than $^{130}$Te. In this work we describe a search for neutrinoless positron emitting electron capture ($0νβ^+EC$) decay in $^{120}$Te with a total TeO$_2$ exposure of 355.7 kg $\cdot$ yr, corresponding to 0.2405 kg $\cdot$ yr of $^{120}$Te. Albeit $0 νββ$ with two final state electrons represents the most promising channel, the emission of a positron and two 511-keV $γ$s make $0νβ^+EC$ decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of $3.4 \cdot 10^{22}$ yr at 90% Credibility Interval (C.I.). After unblinding we find no evidence of $0νβ^+EC$ signal and set a 90% C.I. Bayesian lower limit of $2.9 \cdot 10^{22}$ yr on $^{120}$Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

nucl-ex↗

Final Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0

CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last phase (June 2019 - February 2020). In this letter, we describe the search for neutrinoless double beta decay of $^{82}$Se with a total exposure (phase I + II) of 8.82 kg$\times$yr of isotope. We set a limit on the half-life of $^{82}$Se to the ground state of $^{82}$Kr of T$^{0ν}_{1/2}$($^{82}$Se)$>$ 4.6$\times \mathrm{10}^{24}$ yr (90\% credible interval), corresponding to an effective Majorana neutrino mass m$_{ββ} <$ (263 -- 545) meV. We also set the most stringent lower limits on the neutrinoless decays of $^{82}$Se to the 0$_1^+$, 2$_1^+$ and 2$_2^+$ excited states of $^{82}$Kr, finding 1.8$\times$10$^{23}$ yr, 3.0$\times$10$^{23}$ yr, 3.2$\times$10$^{23}$ yr (90$\%$ credible interval) respectively.

hep-ex↗

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta ($0 νββ$) decay. Here we show results from the search for $0 νββ$ decay of $^{130}$Te, using the latest advanced cryogenic calorimeters with the CUORE experiment. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultra-low temperatures, operational longevity, and the low levels of ionising radiation emanating from the cryogenic infrastructure. We find no evidence for $0 νββ$ decay and set a lower bound of $T_{1/2}^{0 ν} > 2.2 \times 10^{25}$ years at a 90% credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultra-low temperature cryogenic environment.

nucl-ex↗

European Strategy for Particle Physics -- Accelerator R&D Roadmap

The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified in the Strategy update. The R&D objectives include: improvement of the performance and cost-performance of magnet and radio-frequency acceleration systems; investigations of the potential of laser / plasma acceleration and energy-recovery linac techniques; and development of new concepts for muon beams and muon colliders. The goal of the roadmap is to document the collective view of the field on the next steps for the R&D programme, and to provide the evidence base to support subsequent decisions on prioritisation, resourcing and implementation.

physics.acc-ph↗

High precision measurement of the half-life of the 391.6 keV metastable level in 239Pu

Materials selection for rare event physics requires high performance detectors and customized analyses. In this context a novel $β$-$γ$ detection system, comprised of a liquid scintillator in coincidence with a HPGe, was developed with the main purpose of studying ultra trace contamination of uranium, thorium and potassium in liquid samples. In the search for $^{238}\textrm{U}$ contaminations through neutron activation analysis, since the activation product $^{239}\textrm{Np}$ decays to a relatively long-lived isomeric state of $^{239}\textrm{Pu}$, it is possible to perform a time selection of these events obtaining a strong background suppression. Investigating the time distribution of the coincidences between the $β^-$ decay of $^{239}\textrm{Np}$ and the delayed events following the de-excitation of the $^{239}\textrm{Pu}$ isomeric level at 391.6 keV, a precision measurement of the half-life of this level was conducted. The half-life of the 391.6 keV $^{239}\textrm{Pu}$ level resulted $190.2 \pm 0.2$ ns, thus increasing the precision by about a factor of 20 over previous measurements.

nucl-ex↗

Measurements of neutron fields in a wide energy range using multi-foil activation analysis

An accurate characterization of the neutron fields at spallation sources is crucial for many applications based on neutron irradiations, such as radiation damage tests that need a precise dose estimate. In this work we present the neutron flux measurements performed with the multi-foil activation technique in the ROTAX and ChipIr beamlines of the ISIS spallation source, characterized by moderated and unmoderated spectra, respectively. We selected many different activation reactions to cover a wide energy range, from thermal to very fast neutrons up to about 100 MeV. By applying a Bayesian unfolding algorithm, we demonstrate the effectiveness of this technique in measuring the neutron flux intensity and energy spectrum with precision and accuracy.

physics.ins-det↗

Improving radioactive contaminant identification through the analysis of delayed coincidences with an $α$-spectrometer

In the framework of rare event searches, the identification of radioactive contaminants in ultra-pure samples is a challenging task, because the signal is often at the same level of the instrumental background. This is a rather common situation for $α$-spectrometers and other detectors used for low-activity measurements. In order to obtain the target sensitivity without extending the data taking live-time, analysis strategies that highlight the presence of the signal sought should be developed. In this paper, we show how to improve the contaminant tagging capability relying on the time-correlation of radioactive decay sequences. We validate the proposed technique by measuring the impurity level of both contaminated and ultra-pure copper samples, demonstrating the potential of this analysis tool in disentangling different background sources and providing an effective way to mitigate their impact in rare event searches.

physics.ins-det↗