Searcharxiv⌕ Search

arXiv subjects

E. Sanchez Garcia

Publications and source records attributed to E. Sanchez Garcia.

9 recordsLinked to original sources

New constraints on physics within and beyond the standard model from the latest CONUS datasets

Its detections with pion-decay-at-rest, solar and recently with reactor antineutrinos by the CONUS collaboration render coherent elastic neutrino-nucleus scattering (CE$ν$NS) an established tool for investigations within and beyond the Standard Model (SM). The CONUS experiment located at the nuclear power plants in Brokdorf (Germany) and Leibstadt (Switzerland) operates Germanium semiconductor detectors in a compact shield at close distance to the reactor core. An observation with $3.7 σ$ significance is reported at the Leibstadt site, showing good agreement with its SM prediction. Physics investigations performed with the last datasets collected at the Brokdorf reactor and with the first data obtained at the Leibstadt site are summarized. By using the experimental analysis framework, the presented results contain the full systematics that underlie the experiment. Previously determined limits with neutrino-electron scattering on the neutrino magnetic moment and a neutrino millicharge are improved to $μ_ν <5.18\cdot 10^{-11}μ_\mathrm{B}$ and $q_ν<1.76\cdot 10^{-12} e_0$ (90% C.L). Further, the scale of new physics related to NSIs is improved to $Λ_{\rm NSI}$=145 GeV and limits on the coupling of light new mediators are lowered down to $4 \cdot 10^{-7}$ (90% C.L.) with the new data. Finally, the determination of the Weinberg angle with CE$ν$NS and reactor antineutrinos yields $\sin^{2}θ_W= 0.28^{+0.03}_{-0.04}$ at a momentum transfer of $\sim 10 \ \mathrm{MeV}$.

hep-ex↗

The CONUS+ experiment

The CONUS+ experiment aims to detect coherent elastic neutrino-nucleus scattering (CEvNS) of reactor antineutrinos on germanium nuclei in the fully coherent regime, continuing on this way the CONUS physics program started at the Brokdorf nuclear power plant, Germany. The CONUS+ setup is installed in the nuclear power plant in Leibstadt, Switzerland, at a distance of 20.7 m from the 3.6 GW thermal power reactor core. The CEvNS signature will be measured with the same four point-contact high-purity germanium (HPGe) detectors produced for the former experiment, however refurbished and with optimized low energy thresholds. To suppress the background in the CONUS+ detectors, the passive and active layers of the original CONUS shield were modified such to fit better to the significantly changed background conditions at the new experimental location. New data acquisition and monitoring systems were developed. A direct network connection between the experiment and the Max-Planck-Institut fur Kernphysik (MPIK) makes it possible to control and monitor data acquisition in real time. The impact of all these modifications is discussed with particular emphasis on the resulting CEvNS signal prediction for the first data collection phase of CONUS+. Prospects of the planned upgrade in a second phase integrating new larger HPGe detectors are also discussed.

hep-ex↗

Final CONUS results on coherent elastic neutrino-nucleus scattering at the Brokdorf reactor

The Conus experiment studies coherent elastic neutrino-nucleus scattering in four 1 kg germanium spectrometers. Low ionization energy thresholds of 210 eV were achieved. The detectors were operated inside an optimized shield at the Brokdorf nuclear power plant which provided a reactor antineutrino flux of up to 2.3$\cdot$10$^{13}$\,cm$^{-2}$s$^{-1}$. In the final phase of data collection at this site, the constraints on the neutrino interaction rate were improved by an order of magnitude as compared to the previous Conus analysis. The new limit of less than 0.34 signal events kg$^{-1}$\,d$^{-1}$ is within a factor 2 of the rate predicted by the standard model. This constraint is discussed in the context of conflicting measurements and results from another reactor neutrino experiment using similar technology.

hep-ex↗

Background characterization of the CONUS+ experimental location

CONUS+ is an experiment aiming at detecting coherent elastic neutrino-nucleus scattering (CE$ν$NS) of reactor antineutrinos on germanium nuclei in the fully coherent regime, continuing the CONUS physics program conducted at the Brokdorf nuclear power plant (KBR), Germany. The CONUS+ experiment is installed in the Leibstadt nuclear power plant (KKL), Switzerland, at a distance of 20.7 m from the 3.6 GW reactor core, where the antineutrino flux is $1.5\cdot 10^{13}$~s$^{-1}$cm$^{-2}$. The CE$ν$NS signature will be measured with four point-contact high-purity low energy threshold germanium (HPGe) detectors. A good understanding of the background is crucial, especially events correlated with the reactor thermal power are troublesome. A large background characterization campaign was conducted during reactor on and off times to find the best location for the CONUS+ setup. On-site measurements revealed a correlated, highly thermalized neutron field with a maximum fluence rate of $(2.3\pm0.1)\cdot 10^{4}$~neutrons~d$^{-1}$cm$^{-2}$ during reactor operation. The $γ$-ray background was studied with a HPGe detector without shield. The muon flux was examined using a liquid scintillator detector measuring (107$\pm$3)~muons~s$^{-1}$m$^{-2}$, which corresponds to an average overburden of 7.4~m of water equivalent. The new background conditions in CONUS+ are compared to the previous CONUS ones, showing a 30 times higher flux of neutrons, but a 26 times lower component of reactor thermal power correlated $γ$-rays over 2.7 MeV. The lower CONUS+ overburden increases the number of muon-induced neutrons by 2.3 times and the flux of cosmogenic neutrons. Finally, all the measured rates are discussed in the context of the CONUS+ background, together with the CONUS+ modifications performed to reduce the impact of the new background conditions at KKL.

physics.ins-det↗

Pulse shape discrimination for the CONUS experiment in the keV and sub-keV regime

Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are expected to interact homogeneously in the entire detector volume, specific classes of external background radiation preferably deposit their energy close to the semi-active detector surface, in which diffusion processes dominate that subsequently lead to slower rising pulses compared to the ones from the fully active bulk volume. Dedicated studies of their shape are therefore highly beneficial for the understanding and the rejection of these unwanted events. This article reports about the development of a data-driven pulse shape discrimination (PSD) method for the four 1 kg size PPC HPGe detectors of the CONUS experiment in the keV and sub-keV regime down to 210 eV$_{\text{ee}}$. The impact of the electronic noise at such low energies is carefully examined. It is shown that for an acceptance of 90% of the faster signal-like pulses from the bulk volume, approx. 50% of the surface events can be rejected at the energy threshold and that their contribution is fully suppressed above 800 eV$_{\text{ee}}$. Applied to the CONUS background data, such a PSD rejection cut allows to achieve an overall (15-25)% reduction of the total background budget. The new method allows to improve the sensitivity of future CONUS analyses and to refine the corresponding background model in the sub-keV energy region.

physics.ins-det↗

Spectroscopic analysis of the argon scintillation with a wavelength sensitive particle detector

We performed a time-resolved spectroscopic study of the VUV/UV argon scintillation as a function of pressure and electric field, by means of a wavelength sensitive detector operated with different radioactive sources. Our work conveys new evidence of distinctive features of the argon light which are in contrast with the general assumption that, for particle detection purposes, the scintillation can be considered to be largely monochromatic at 128 nm (second continuum). The wavelength and the time-resolved analysis of the photon emission reveal that the dominant component of the argon scintillation during first tens of ns is in the range [160, 325] nm. This light is consistent with the third continuum emission from highly charged argon ions/molecules. This component of the scintillation is field-independent up to 25 V/cm/bar and shows a very mild dependence with pressure in the range [1,16] bar. The dynamics of the second continuum emission is dominated by the excimer formation time, whose variation as a function of the pressure has been measured. Additionally, the time and pressure-dependent features of electron-ion recombination, in the second continuum band, have been measured. This study opens new paths toward a novel particle identification technique based on the spectral information of the noble-elements scintillation light.

physics.ins-det↗

AVOLAR. A high voltage generator for liquid argon time projection chambers

Some of the main neutrino oscillation and dark matter experiments have chosen time projection chambers (TPC) filled with liquid argon (LAr) as their technology for the next generation of detectors. Because of its typical drift length of several meters, relatively large cathode voltages are desirable to provide a sizeable drift field. Current designs are based on feedthroughs with high voltages (HV) limited to several hundred kV. The present work proposes a novel method to produce higher voltages inside the detector. It is based on a Van de Graaff HV generator where the charge transporting belt is replaced by a cryogenic LAr flow. Negative charge is injected in liquid by means of a grounded sharp point facing a positive voltage electrode with a high speed LAr stream in between. The LAr flow transports the charge to the cathode through an electrically insulating pipe. In the cathode the charge is extracted with a metallic mesh. The LAr flux is driven by a cryogenic helium pump with unidirectional valves assuring a continuous flow. The LAr operational temperature is maintained by a pressurized liquid nitrogen deposit with automatic filling. The whole system is installed within a dewar container that will be filled with LAr reproducing the typical TPC conditions. This design has no mobile parts, so it is very robust and can be easily embedded within the structural support of a TPC cathode. A prototype of this HV generator has been constructed at CIEMAT (Madrid), and is currently being characterized. This R&D is presented and the preliminary results are discussed.

physics.ins-det↗

Impact of the positive ion current on large size neutrino detectors and delayed photon emission

Given their small mobility coefficient in liquid argon with respect to the electrons, the ions spend a considerably longer time in the active volume. We studied the effects of the positive ion current in a liquid argon time projection chamber, in the context of massive argon experiments for neutrino physics. The constant recombination between free ions and electrons produces a quenching of the charge signal and a constant emission of photons, uncorrelated in time and space to the physical interactions. The predictions evidence some potential concerns for multi-ton argon detectors, particularly when operated on surface

physics.ins-det↗

Group convolutional codes

In this note we introduce the concept of group convolutional code. We make a complete classification of the minimal $S_3$-convolutional codes over the field of five elements by means of Jategaonkar's theorems.

math.RA↗