SearcharxivSearch

arXiv · 2308.12105

Pulse shape discrimination for the CONUS experiment in the keV and sub-keV regime

Abstract

Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are expected to interact homogeneously in the entire detector volume, specific classes of external background radiation preferably deposit their energy close to the semi-active detector surface, in which diffusion processes dominate that subsequently lead to slower rising pulses compared to the ones from the fully active bulk volume. Dedicated studies of their shape are therefore highly beneficial for the understanding and the rejection of these unwanted events. This article reports about the development of a data-driven pulse shape discrimination (PSD) method for the four 1 kg size PPC HPGe detectors of the CONUS experiment in the keV and sub-keV regime down to 210 eV$_{\text{ee}}$. The impact of the electronic noise at such low energies is carefully examined. It is shown that for an acceptance of 90% of the faster signal-like pulses from the bulk volume, approx. 50% of the surface events can be rejected at the energy threshold and that their contribution is fully suppressed above 800 eV$_{\text{ee}}$. Applied to the CONUS background data, such a PSD rejection cut allows to achieve an overall (15-25)% reduction of the total background budget. The new method allows to improve the sensitivity of future CONUS analyses and to refine the corresponding background model in the sub-keV energy region.

Explore related subjects

Keep this discovery

BibTeXRIS

H. Bonet, A. Bonhomme, C. Buck, K. Fülber, J. Hakenmüller, J. Hempfling, J. Henrichs, G. Heusser, M. Lindner, W. Maneschg, T. Rink, E. Sanchez Garcia, J. Stauber, H. Strecker, R. Wink. 2023-08-23. Pulse shape discrimination for the CONUS experiment in the keV and sub-keV regime. https://doi.org/10.1140/epjc%2Fs10052-024-12470-w

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det