Vocabulary, Physical Quantities and Units for the Measurement of Amplitude Noise and Phase Noise

The widespread use of non-SI quantities and units, together with improper and misleading terminology, generates confusion in the domain of phase and amplitude noise. We discuss such physical quantities, units and terms with the purpose of stimulating a discussion between labs, and to agree for the full adoption of the International System of Units (SI) and clear, unambiguous terminology.

physics.ins-det

Phase noise measurement of semiconductor optical amplifiers

We introduce a novel measurement method for the phase noise measurement of optical amplifiers, topologically similar to the Heterodyne Mach-Zehnder Interferometer but governed by different principles, and we report on the measurement of a fibered amplifier at 1.55 $\mu\mathrm{m}$ wavelength. The amplifier under test (DUT) is inserted in one arm of a symmetrical Mach-Zehnder interferometer, with an AOM in the other arm. We measure the phase noise of the RF beat detected at the Mach-Zehnder output. The phase noise floor of the amplifier decreases proportionally to the reciprocal of the laser power at the amplifier input, down to $-125$ $\mathrm{dBrad^2/Hz}$ at $f=100$ $\mathrm{kHz}$. The DUT flicker noise cannot be measured because it is lower than the background of the setup. This sets an upper bound of the amplifier noise at $-32$ $\mathrm{dBrad^2/Hz}$ at $f=1$ $\mathrm{Hz}$, which corresponds to a frequency stability of $5.2{\times}10^{-17}/\tau$ (Allan deviation), where $\tau$ is the integration time. Such noise level is lower than that of most Fabry-Perot cavity-stabilized lasers. These results are of interest in a wide range of applications including metrology, instrumentation, optical communications, or fiber links.

physics.optics

Phase noise of a microwave photonic channel: direct-current versus external electro-optic modulation

We characterize the phase noise of a microwave photonic channel, where a 10 GHz signal is carried by an intensity-modulated light beam over a short optical fiber, and detected. Two options are compared, (i) an electro-optic modulator (EOM), and (ii) the direct modulation of the laser current. The 1.55~$\mu$m laser and the detector are the same. The effect of experimental parameters is investigated, the main of which are the microwave power and the laser bias current. The main result is that the upper bound of the phase flicker is $-117$~dBrad$^2$ in the case of the EOM, limited by the background noise of the setup. In contrast, with direct modulation of the laser, the flicker is of $-114$ to $-100$~dBrad$^2$, depending on the laser bias current (50--90~mA), and the highest noise occurs at the lowest bias. Our results are of interest in communications, radar systems, instrumentation and metrology.

physics.optics

A Cryogenic Sapphire Resonator Oscillator with 1e-16 mid-term fractional frequency stability

We report in this letter the outstanding frequency stability performances of an autonomous cryogenique sapphire oscillator presenting a flicker frequency noise floor below 2e-16 near 1,000 s of integration time and a long term Allan Deviation (ADEV) limited by a random walk process of 1e-18/sqr(tau). The frequency stability qualification at this level called for the implementation of sophisticated instrumentation associated with ultra-stable frequency references and ad hoq averaging and correlation methods.

physics.ins-det

Reliability and Reproducibility of the Cryogenic Sapphire Oscillator Technology

The cryogenic sapphire oscillator (CSO) is a highly specialized machine, which delivers a reference signal exhibiting the lowest frequency fluctuations. For the best units, the Allan deviation (ADEV) is <1e-15 for integration time between 1 and 10,000 s, with a drift <1e-14 in one day.The oscillator is based on a sapphire monocrystal resonating at 10 GHz in a whispering-gallery mode, cooled at 6 K for highest Q-factor and zero thermal coefficient. We report on the progress accomplished implementing eleven CSOs in about 10 years since the first sample delivered to the ESA station in Argentina. Short-term stability is improved by a factor of 3-10, depending on the integration time, and the refrigerator's electric power is reduced to 3 kW. Frequency stability and overall performances are reproducible, with unattended operation between scheduled maintenance every two years. The CSO is suitable to scientific applications requiring extreme frequency stability with reliable long-term operation. For example, the flywheel for primary frequency standards, the ground segment of GNSS, astrometry, VLBI, and radio astronomy stations.

physics.ins-det

The Statistics of the Cross-Spectrum and the Spectrum Average: Generalization to Multiple Instruments

This article addresses the measurement of the power spectrum of red noise processes at the lowest frequencies, where the minimum acquisition time is so long that it is impossible to average on a sequence of data record. Therefore, averaging is possible only on simultaneous observation of multiple instruments. This is the case of radio astronomy, which we take as the paradigm, but examples may be found in other fields such as climatology and geodesy. We compare the Bayesian confidence interval of the red-noise parameter using two estimators, the spectrum average and the cross-spectrum. While the spectrum average is widely used, the cross-spectrum using multiple instruments is rather uncommon. With two instruments, the cross-spectrum estimator leads to the Variance-Gamma distribution. A generalization to $q$ devices is provided, with the example of the observation of millisecond pulsars with 5 radio telescopes.

physics.data-an

The Companion of Enrico's Chart for Phase Noise and Two-Sample Variances

Phase noise and frequency (in)stability both describe the fluctuation of stable periodic signals, from somewhat different standpoints. Frequency is unique compared to other domains of metrology, in that its fluctuations of interest span at least 14 orders of magnitude, from $10^{-4}$ in a mechanical watch to $10^{-18}$ in atomic clocks. The frequency span of interest is some 12-15 orders of magnitude, from $\mu$Hz to GHz Fourier frequency for phase noise, while the time span over which the fluctuations occur ranges from sub-$\mu$s to years integration time for variances. Because this domain is ubiquitous in science and technology, a common language and tools suitable to the variety mentioned are a challenge. This article is at once (1) a tutorial, (2) a review covering the most important facts about phase noise, frequency noise and two-sample (Allan and Allan-like) variances, and (3) a user guide to "Enrico's Chart of Phase Noise and Two-Sample Variances." In turn, the Chart is a reference card collecting the most useful concepts, formulas and plots in a single A4/A-size sheet, intended to be a staple on the desk of whoever works with these topics. The Chart is available under Creative Commons 4.0 CC-BY-NC-ND license from Zenodo, DOI 10.5281/zenodo.4399218. A wealth of auxiliary material is available for free on the Enrico's home page http://rubiola.org. This version includes the corrections for an unfortunate error in the normalization of the Hadamard version, and some corrections for trivial (albeit sometimes subtle) mistakes.

physics.ins-det

Applying clock comparison methods to pulsar timing observations

Frequency metrology outperforms any other branch of metrology in accuracy (parts in $10^{-16}$) and small fluctuations ($<10^{-17}$). In turn, among celestial bodies, the rotation speed of millisecond pulsars (MSP) is by far the most stable ($<10^{-18}$). Therefore, the precise measurement of the time of arrival (TOA) of pulsar signals is expected to disclose information about cosmological phenomena, and to enlarge our astrophysical knowledge. Related to this topic, Pulsar Timing Array (PTA) projects have been developed and operated for the last decades. The TOAs from a pulsar can be affected by local emission and environmental effects, in the direction of the propagation through the interstellar medium or universally by gravitational waves from super massive black hole binaries. These effects (signals) can manifest as a low-frequency fluctuation over time, phenomenologically similar to a red noise. While the remaining pulsar intrinsic and instrumental background (noise) are white. This article focuses on the frequency metrology of pulsars. From our standpoint, the pulsar is an accurate clock, to be measured simultaneously with several telescopes in order to reject the uncorrelated white noise. We apply the modern statistical methods of time-and-frequency metrology to simulated pulsar data, and we show the detection limit of the correlated red noise signal between telescopes.

physics.data-an

Response and Uncertainty of the Parabolic Variance PVAR to Non-Integer Exponents of the Power Law

Oscillator fluctuations are described as the phase or frequency noise spectrum, or in terms of a wavelet variance as a function of the measurement time. The spectrum is generally approximated by the `power law,' i.e., a Laurent polynomial with integer exponents of the frequency. This article extends the domain of application of PVAR, a wavelet variance which uses the linear regression on phase data to estimate the frequency, and called `parabolic' because such regression is equivalent to a parabolic-shaped weight function applied to frequency fluctuations. In turn, PVAR is relevant in that it improves on the widely-used Modified Allan variance (MVAR) enabling the detection of the same noise processes at the same confidence level in a shorter measurement time. More specifically, we provide (i) the analytical expression of the response of the PVAR to the frequency-noise spectrum in the general case of non-integer exponents of the frequency, and (ii) a useful approximate expression of the statistical uncertainty.

physics.data-an

Artifacts and Errors in Cross-Spectrum Phase Noise Measurements

This article deals with the erratic and inconsistent phase-noise spectra often seen in low-noise oscillators, whose floor is of the order of $-180$ dBc/Hz or less. Such oscillators are generally measured with two-channel instruments based on averaging two simultaneous and statistically independent measures. Our new method consists of inserting a dissipative attenuator between the oscillator under test and the phase-noise analyzer. The thermal noise of the attenuator introduces a controlled amount of phase noise. We compare the phase noise floor to the theoretical expectation with different values of the attenuation in small steps. The analysis reveals a negative bias (underestimation of phase noise) due to the thermal energy of the internal power splitter at the instrument input, and an uncertainty due to crosstalk between the two channels. In not-so-rare unfortunate cases, the bias results in a negative phase-noise spectrum, which is an obvious nonsense. Similar results are observed separately in three labs with instruments from the two major brands. We give experimental evidence, full theory, and suggestions to mitigate the problem. Our multiple-attenuators method provides quantitative information about the correlation phenomena inside the instrument.

physics.ins-det

Cross-Spectrum Measurement Statistics

The cross-spectrum method consists in measuring a signal $c(t)$ simultaneously with two independent instruments. Each of these instruments contributes to the global noise by its intrinsec (white) noise, whereas the signal $c(t)$ that we want to characterize could be a (red) noise. We first define the real part of the cross-spectrum as a relevant estimator. Then, we characterize the probability density function (PDF) of this estimator knowing the noise level (direct problem) as a Variance-Gamma (V$Γ$) distribution. Next, we solve the "inverse problem" thanks to Bayes' theorem to obtain an upper limit of the noise level knowing the estimate. Checked by massive Monte Carlo simulations, V$Γ$ proves to be perfectly reliable to any number of degrees of freedom (dof). Finally we compare this method with an other method using the Karhunen-Loève transfrom (KLT). We find an upper limit of the signal level slightly different as the one of V$Γ$ since KLT better takes into account the available informations.

physics.data-an

Phase Sensitivity and Phase Noise of Cantilever-Type Magnetoelastic Sensors Based on the $Δ$E Effect

Magnetoelastic sensors for the detection of low-frequency and low-amplitude magnetic fields are in the focus of research since more than 30 years. In order to minimize the limit of detection (LOD) of such sensor systems, it is of high importance to understand and to be able to quantify the relevant noise sources. In this contribution, cantilever-type electromechanic and magnetoelastic resonators, respectively, are comprehensively investigated and mathematically described not only with regard to their phase sensitivity but especially to the extent of the sensor-intrinsic phase noise. Both measurements and calculations reveal that the fundamental LOD is limited by additive phase noise due to thermal-mechanical noise of the resonator, i.e. by thermally induced random vibrations of the cantilever, and by thermal-electrical noise of the piezoelectric material. However, due to losses in the magnetic material parametric flicker phase noise arises, limiting the overall performance. In particular it is shown that the LOD is virtually independent of the magnetic sensitivity but is solely determined by the magnetic losses. Instead of the sensitivity, the magnetic losses, represented by the material's effective complex permeability, should be considered as the most important parameter for the further improvement of such sensors in the future. This implication is not only valid for magnetoelastic cantilevers but also applies to any type of magnetoelastic resonator.

physics.ins-det

Influence of flicker noise and nonlinearity on the frequency spectrum of spin torque nano-oscillators

The correlation of phase fluctuations in any type of oscillator fundamentally defines its spectral shape. However, in nonlinear oscillators, such as spin torque nano oscillators, the frequency spectrum can become particularly complex. This is specifically true when not only considering thermal but also colored $1/f$ flicker noise processes, which are crucial in the context of the oscillator's long term stability. In this study, we address the frequency spectrum of spin torque oscillators in the regime of large-amplitude steady oscillations experimentally and as well theoretically. We particularly take both thermal and flicker noise into account. We perform a series of measurements of the phase noise and the spectrum on spin torque vortex oscillators, notably varying the measurement time duration. Furthermore, we develop the modelling of thermal and flicker noise in Thiele equation based simulations. We also derive the complete phase variance in the framework of the nonlinear auto-oscillator theory and deduce the actual frequency spectrum. We investigate its dependence on the measurement time duration and compare with the experimental results. Long term stability is important in several of the recent applicative developments of spin torque oscillators. This study brings some insights on how to better address this issue.

cond-mat.mes-hall

Ultra-compact reference ULE cavity

We present a first experimental characterization of our ultra-compact, ultra-stable laser. The heart of the apparatus is an original Fabry-Perot cavity with a 25 mm length and a pyramidal geometry, equipped with highly-reflective crystalline coatings. The cavity, along with its vacuum chamber and optical setup, fits inside a 30 L volume. We have measured the cavity thermal and vibration sensitivities, and present a first estimation of the cavity fractional frequency instability at $σ_y(1\rm{s})=7.5{\times}10^{-15}$.

physics.ins-det

KLTS: A rigorous method to compute the confidence intervals for the Three-Cornered Hat and for Groslambert Covariance

The three-cornered hat / Groslambert Covariance methods are widely used to estimate the stability of each individual clock in a set of three, but no method gives reliable confidence intervals for large integration times. We propose a new KLTS (Karhunen-Loève Tansform using Sufficient statistics) method which uses these estimators to take into account the statistics of all the measurements between the pairs of clocks in a Bayesian way. The resulting Cumulative Density Function (CDF) yields confidence intervals for each clock AVAR. This CDF provides also a stability estimator which is always positive. Checked by massive Monte-Carlo simulations, KLTS proves to be perfectly reliable even for one degree of freedom. An example of experimental measurement is given.

physics.data-an

Low offset frequency $1/f$ flicker noise in spin torque vortex oscillators

Low frequency noise close to the carrier remains little explored in spin torque nano oscillators. However, it is crucial to investigate as it limits the oscillator's frequency stability. This work addresses the low offset frequency flicker noise of a TMR-based spin-torque vortex oscillator in the regime of large amplitude steady oscillations. We first phenomenologically expand the nonlinear auto-oscillator theory aiming to reveal the properties of this noise. We then present a thorough experimental study of the oscillator's $1/f$ flicker noise and discuss the results based on the theoretical predictions. Hereby, we connect the oscillator's nonlinear dynamics with the concept of flicker noise and furthermore refer to the influence of a standard $1/f$ noise description based on the Hooge formula, taking into account the non-constant magnetic oscillation volume, which contributes to the magnetoresistance.

cond-mat.mes-hall

Phase-Noise and Amplitude-Noise Measurement of DACs and DDSs

This article proposes a method for the measurement of Phase Noise (PN, or PM noise) and Amplitude Noise (AN, or AM noise) of Digital-to-Analog Converters (DAC) and Direct Digital Synthesizers (DDS) based on modulation-index amplification. The carrier is first reduced by a controlled amount (30-40 dB) by adding a reference signal of nearly equal amplitude and opposite in phase. Then, residual carrier and noise sidebands are amplified and sent to a conventional PN analyzer. The main virtues of our method are: (i) the noise specs of the PN analyzer are relaxed by a factor equal to the carrier suppression ratio; and, (ii) the capability to measure the AN using a PN analyzer, with no need for the analyzer to feature AN measurement. An obvious variant enables AN and PN measurements using an AN analyzer with no PN measurement capability. Such instrument is extremely simple and easy to implement with a power-detector diode followed by a FFT analyzer. Unlike the classical bridge (interferometric) method, there is no need for external line stretcher and variable attenuators because phase and amplitude control is implemented in the device under test. In one case (AD9144), we could measure the noise over 10 decades of frequency. The flicker noise matches the exact $1/f$ law with a maximum discrepancy of $\pm1$ dB over 7.5 decades. Thanks to simplicity, reliability, and low background noise, this method has the potential to become the standard method for the AN and PN measurement of DACs and DDSs.

physics.ins-det