SearcharxivSearch

arXiv · 2201.07109

The Companion of Enrico's Chart for Phase Noise and Two-Sample Variances

Abstract

Phase noise and frequency (in)stability both describe the fluctuation of stable periodic signals, from somewhat different standpoints. Frequency is unique compared to other domains of metrology, in that its fluctuations of interest span at least 14 orders of magnitude, from $10^{-4}$ in a mechanical watch to $10^{-18}$ in atomic clocks. The frequency span of interest is some 12-15 orders of magnitude, from $\mu$Hz to GHz Fourier frequency for phase noise, while the time span over which the fluctuations occur ranges from sub-$\mu$s to years integration time for variances. Because this domain is ubiquitous in science and technology, a common language and tools suitable to the variety mentioned are a challenge. This article is at once (1) a tutorial, (2) a review covering the most important facts about phase noise, frequency noise and two-sample (Allan and Allan-like) variances, and (3) a user guide to "Enrico's Chart of Phase Noise and Two-Sample Variances." In turn, the Chart is a reference card collecting the most useful concepts, formulas and plots in a single A4/A-size sheet, intended to be a staple on the desk of whoever works with these topics. The Chart is available under Creative Commons 4.0 CC-BY-NC-ND license from Zenodo, DOI 10.5281/zenodo.4399218. A wealth of auxiliary material is available for free on the Enrico's home page http://rubiola.org. This version includes the corrections for an unfortunate error in the normalization of the Hadamard version, and some corrections for trivial (albeit sometimes subtle) mistakes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Enrico Rubiola, Francois Vernotte. 2022-01-18. The Companion of Enrico's Chart for Phase Noise and Two-Sample Variances. https://doi.org/10.1109/tmtt.2023.3238267

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det