SearcharxivSearch

arXiv subjects

Eric D. Miller

Publications and source records attributed to Eric D. Miller.

At least 19 recordsLinked to original sources

Curving X-ray detectors for astrophysics applications

Next-generation X-ray optics will revolutionize high-energy astrophysics, yet they present several challenges to design a complementary focal plane. In particular, the focal surface is curved, requiring many small, flat sensors to achieve a large field. We present work building on MIT Lincoln Laboratory technology to curve the sensor itself, improving image quality and reducing complexity. Applying this technology to back-illuminated, large-format CCDs having well-characterized X-ray response, we describe the process and report success curving functional BI CCDs to a 2.5-m radius of curvature, achieving RMS curvature deviations less than 1 micron. We confirm that there is no appreciable increase in dark current and that the spectroscopic performance across the 0.3-6 keV band remains excellent. These results demonstrate that curved, large-format X-ray sensors are realizable, and the process can be extended to silicon detectors with other architectures, including active pixel sensors.

astro-ph.IM

X-ray grating spectroscopy as a mission enhancement

We propose to add instruments to any potential future X-ray mission with focussing optics that is considered in NASA's ASTRA framework. Such an instrument is a necessity to study AGN wind outflows and feedback, find the missing baryons, study the intergalactic medium, and analyze abundances and chemical bonds in dust grains throughout the Milky Way. We conclude that those science goals can be achieved with a spectral resolving power > 3000 in the soft X-ray band (about 10-40 Ang) and an effective area a few times larger than current instruments. We describe a possible mission implementation for a soft X-ray grating spectrometer that can be folded in and out or be mounted permanently in the beam. Such an instrument can reach the requirements for a wide variety of host mission properties. A small UV imager and a UV spectrograph can be mounted on the same platform with independent optics. These added instruments vastly enhance the science capabilities of the host mission for a modest cost (100-200 million $) and with weight and power needs that can be easily accommodated in any major mission.

astro-ph.IM

XRISM reveals sloshing-driven gas motions in the core of Abell 2029

We investigate the velocity structure of the intracluster medium (ICM) in the core of the relaxed cool-core cluster Abell 2029 using XRISM Resolve spectroscopy. We analyze combined XRISM Resolve observations and divide the central region into several subregions. To account for photon mixing caused by the XRISM point spread function, we perform a spatial-spectral mixing analysis. We detect an ordered line-of-sight bulk-velocity gradient across the cluster core: the northern regions are blueshifted relative to the brightest cluster galaxy (BCG), while the southern regions are close to zero velocity or slightly redshifted. The maximum velocity difference is about $280~{\rm km\,s^{-1}}$. In contrast, the turbulent velocity dispersion is smaller, with measured values and upper limits of $\lesssim150~{\rm km\,s^{-1}}$, implying a non-thermal pressure fraction below $\sim2.5\%$. The velocity pattern is consistent with gas sloshing associated with the spiral structure seen in Chandra X-ray images. Averaged over all regions, the inferred turbulent heating rate is below the radiative cooling rate, indicating that turbulent dissipation alone is insufficient to offset cooling in the entire core. These results reveal that A2029 is not kinematically featureless: sloshing-induced bulk motions are present, while the observed line-of-sight velocity dispersion indicates only a limited contribution to pressure support and core heating.

astro-ph.HE

Fast, low noise, megapixel detector and readout systems for future X-ray astronomy missions

Next-generation strategic X-ray astronomy missions will require the simultaneous achievement of high angular resolution, large effective collecting area, and wide-field imaging with large-format focal plane detectors. Realizing the associated science objectives--ranging from precision measurements of bright point sources to the detection and characterization of faint diffuse emission-places stringent and, in some cases, competing requirements on detector performance. In particular, high frame rates are necessary to mitigate photon pile-up in observations of bright sources and to reduce contamination from particle-induced background in measurements of low surface brightness structures. At the same time, these instruments must preserve excellent soft X-ray response, which places tight constraints on read noise and on the fidelity of event characterization. State-of-the-art X-ray charge-coupled devices (CCDs) approach many of the key performance metrics required for these missions, but readout speed remains a primary limitation. Addressing this gap requires readout architectures that scale to high channel count, sustain high pixel throughput, and preserve the low-noise characteristics needed for soft X-ray sensitivity.

astro-ph.IM

High-speed, low-noise, multi-megapixel CCDs for next generation X-ray observatories

Next generation X-ray observatories require fast, low-noise, low-power, multi-megapixel imaging spectrometers. To meet these demands, the X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in partnership with the MIT Kavli Institute and MIT Lincoln Laboratory (MIT-LL), is developing multi-channel X-ray charge-coupled devices (CCDs) and fast readout architectures. We report the energy resolution and noise performance achieved with a full-scale (1440x1440-pixel), 16-channel, front-illuminated MIT-LL CCD detector developed for the Advanced X-ray Imaging Satellite (AXIS) concept, the CCID-100, read out using two Multi-Channel Readout Chip (MCRC) V1 application-specific integrated circuit (ASIC) chips in the new Stanford CCID-100 test setup. We describe an automated method for bias optimization on each CCD channel, and integrated debugging features of the front-end ASIC and readout system. The demonstrated performance confirms that these systems can meet the speed and noise requirements of future strategic X-ray missions.

astro-ph.IM

High-statistics simulations of NewAthena WFI background using Geant4

The observation of hot gas structures is one science goal of the Wide Field Imager (WFI) on ESA's NewAthena X-ray observatory. Because the measurement of these faint diffuse sources is limited by background from cosmic ray particle interactions within the instrument, understanding and reducing this background is critical. To this end, we employ a two-pronged approach, performing high-fidelity Geant4 simulations on both detailed, realistic geometry models as well as complementary simple geometry models. The former can reveal subtle sensitivities of background to details of the instrument design. The latter allows for fast iteration, useful in guiding and understanding the larger simulations. We show how we leverage High Performance Computing (HPC) resources to achieve simultaneously high throughput and fast time to result. We discuss our recent results, which are applicable not only to WFI, but also other X-ray missions.

astro-ph.IM

Output-Stage Design Optimization for High-Sensitivity SiSeRO CCDs and SiSeRO Active Pixel Sensors

The Single electron Sensitive Read Out (SiSeRO) technology is a new device class designed to support the needs of future X-ray and optical astronomical telescopes that will require fast, low-noise, megapixel spectro-imagers. Developed at MIT Lincoln Laboratory, in collaboration with Stanford University and MIT, the first generation SiSeRO-CCD (charge-coupled device) prototypes achieved a charge/current conversion gain of 700$-$800 pA per electron, an equivalent noise charge (ENC) of around 3.5 electrons root mean square (RMS), and a full width half maximum (FWHM) energy resolution of approximately 130 eV at 5.9 keV at a readout speed of 625 kpix/s. Utilizing Repetitive Non-Destructive Readout (RNDR), these same devices also demonstrated sub-electron noise performance (ENC$<$0.5 electrons RMS) at a readout speed of 10 kpix/s. We present the results of device simulations for next-generation SiSeRO CCD output stages that optimize the sensing transistor and its internal gate geometry to enhance noise and speed performance. Further, the goal is to develop a SiSeRO active pixel sensor (APS) that combines the proven X-ray performance of CCDs with the architectural advantages of an APS. Enabling this requires substantial design updates, for example, incorporating two SiSeRO amplifiers side by side on each pixel and shuffling the charge between them to support RNDR. We discuss our device simulation framework and design parameter optimization in the first-generation SiSeRO devices.

astro-ph.IM

Fast, low-noise CCD systems for future strategic X-ray missions

Future strategic X-ray missions, such as those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and noise capabilities required by such programs, our Stanford team, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing enhanced X-ray charge-coupled devices (CCDs) and readout systems that leverage tailored application-specific integrated circuits (ASICs). Here, we report the energy resolution and noise performance achieved using some of the latest MIT-LL CCDs in conjunction with Stanford-developed Multi-Channel Readout Chip (MCRC) ASICs. Additionally, we present a new sampling method for simultaneous optimization of the output gate (OG), reset gate (RG), and reset drain (RD) biases which, in combination with new integrated fast summing well (SW) and RG clock operation modes, enables the data rates and noise required for future X-ray telescopes. Finally, we present noise power spectral density (PSD) and waveform analysis methods and posit a physical model for characterizing and understanding output stage noise behavior.

astro-ph.IM

The High-Speed FPGA Readout System for the Advanced X-ray Imaging Satellite (AXIS)

The Advanced X-ray Imaging Satellite (AXIS) is a Probe-class mission concept designed to deliver arcsecond spatial resolution, high-sensitivity spectral imaging across the 0.3-10 keV band. The X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing the AXIS X-ray camera, including both the detector and the front-end readout electronics required to meet the mission's demanding performance goals. The telescope's focal plane detector consists of four 1440x1440 pixel charge-coupled devices (CCDs) developed by MIT-LL, each featuring 16 parallel output channels. These outputs are amplified by a high-speed, low-power, low-noise application-specific integrated circuit (ASIC) - the Multi-Channel Readout Chip (MCRC) - developed at Stanford. Following amplification, the analog signals are digitized and processed to construct a pixel array, prior to event detection. Here, we present the field-programmable gate array (FPGA) architecture developed to enable high-speed, parallelized readout of these CCD channels. The FPGA samples 16 analog-to-digital converter (ADC) channels at 50 MHz, performs preprocessing of pixel data, which is then streamed via User Datagram Protocol (UDP) over a 1 Gb Ethernet link to the back-end system for event reconstruction. Our design demonstrates the goal readout performance for AXIS (20 frames per second) and provides a framework for future high-throughput X-ray observatories.

astro-ph.IM

RNDR noise modeling in first-generation Single electron Sensitive Readout (SiSeRO) devices

Flagship observatories require single-photon detectors with ultra-fast readout, sub-electron noise performance, and scalable large-format architectures. The X-ray Astronomy and Observational Cosmology group at Stanford, in collaboration with the MIT Kavli Institute and MIT Lincoln Laboratory, is developing readout technologies for next-generation detectors. Prototypes employing Single-electron Sensitive Readout (SiSeRO) amplifiers demonstrate excellent read noise and spectral performance using repetitive non-destructive readout (RNDR), achieving 0.5 e$^-$ noise in under 57 cycles. We have modeled noise for longer RNDR cycles, exploring probabilistic mechanisms such as thermal leakage and impact ionization. Here we present our model results, including statistical limits on dark current-like signals. Maturation of SiSeRO technology will improve detector performance at soft X-ray energies, addressing technology gaps for future X-ray and UV/visible/near-IR observatories.

astro-ph.IM

First results for second generation SiSeRO CCD devices

The Astro2020 Decadal recommended the development of a suite of next generation astronomical observatories spanning the X-ray to near-IR spectrum. These programs require fast, extremely low noise detectors to fulfill their science goals. To address this technology gap, Stanford X-ray Astronomy and Observational Cosmology (XOC) group, MIT Lincoln Laboratory (MIT-LL), and MIT Kavli Institute (MKI) are advancing Single electron Sensitive Read Out (SiSeRO), a multiband detector technology capable of achieving substantially sub-electron noise via Repetitive Non-Destructive Readout (RNDR). We present initial results for our second generation SiSeRO CCDs. We also discuss our test bed, including a readout electronics system capable of accommodating all second-generation SiSeRO CCD variants utilizing the XOC-designed Multi-Channel Readout Chip (MCRC) ASIC.

astro-ph.IM

XRISM Reveals a Kinematically Coherent Core System of the Nearby Cool-Core Cluster Abell 2199

We present the results of a deep 251 ks XRISM/Resolve observation of the cool core of the galaxy cluster Abell 2199. From the integrated spectrum of the central $3' \times 3'$ Resolve field of view ($104 \times 104 \mathrm{~kpc}^2$), we find that the intracluster medium (ICM) redshift is consistent with that of the brightest cluster galaxy, within the optical-redshift uncertainty. This indicates that they form a kinematically coherent core system, which offset from the mean cluster redshift by $\sim200~\mathrm{km~s^{-1}}$. The observed velocity dispersion of $\sim100~\mathrm{km~s^{-1}}$ corresponds to a three-dimensional Mach number of $M_{\mathrm{3D}}=0.16$ and a non-thermal pressure fraction of $P_{\mathrm{NT}}/P_{\mathrm{tot}}=1.4\pm0.2$%. Abell 2199 is one of the most dynamically quiescent relaxed clusters observed with XRISM, despite the presence of radio jets and a plume-like structure possibly associated with sloshing motions. Order-of-magnitude estimates suggest that turbulent dissipation could offset a non-negligible fraction of the radiative cooling losses, with $Q_{\mathrm{turb}}/Q_{\mathrm{cool}}\approx0.2$ for a large-scale driver such as sloshing and larger values for smaller AGN-feedback scales. Finally, we detect a localized enhancement of the Fe XXV He$\alpha$ $y$ line in the southeast region, which spatially coincides with a Chandra surface brightness discontinuity.

astro-ph.GA

Chemical enrichment of the Perseus cluster core seen by XRISM/Resolve

The intracluster medium (ICM) is rich in chemical elements, produced by core-collapse (SNcc) and Type Ia supernovae (SNIa) over the last $\sim$12 Gyr. Whereas cluster outskirts are uniformly enriched with Fe at $\sim$0.3 solar - strongly suggesting that the gas had been pre-enriched during or before the assembly of galaxies into clusters, the Fe abundance is known to centrally increase in the core of relaxed clusters. The origin of these central Fe peaks however, as well as the apparent presence of mysterious drops previously reported in the very centre of a number of systems, remain to be clarified. In this paper, we address these two questions by measuring the spatial distribution of Fe and its relative Si/Fe, S/Fe, Ar/Fe, Ca/Fe, Cr/Fe, Mn/Fe, and Ni/Fe ratios in the X-ray bright, nearby Perseus cluster. We take advantage of the unprecedented spectral resolution ($\sim$5 eV) offered by the Resolve microcalorimeter on board XRISM, which observed four distinct pointings of Perseus out to $\sim$250 kpc ($\sim$0.2$r_{500}$) during its Performance Verification phase. Although the presence of an X-ray bright AGN challenges a precise quantification of absolute abundances in the very core, our baseline analysis rules out a strong drop with $>$2$\sigma$ confidence, at variance with previous CCD measurements. In addition, we find a remarkable spatial uniformity of X/Fe ratios, supporting the idea of negligible late SNIa enrichment from the brightest cluster galaxy NGC 1275. We also compare the overall chemical composition of the Perseus ICM with SNcc and SNIa nucleosynthesis yield models, finding that the co-existence of two separate SNIa enrichment channels is not needed to reproduce the ICM ratios satisfactorily.

astro-ph.GA

XRISM Observations of Abell 1795: Evidence for Low Turbulence and Resonant Scattering

We present high-resolution X-ray spectroscopic observations of the cool-core galaxy cluster Abell~1795 obtained with XRISM/Resolve. The cluster was observed with two deep pointings: a 225 ks central exposure and a 113 ks northern exposure, extending to a projected radius of 320 kpc from the cluster center. Single-temperature fits reveal a clear radial gradient in the line-of-sight velocity dispersion, decreasing from 114 $\pm$ 11 km/s in the core to 68 $\pm$ 39 km/s at 320 kpc. The bulk velocities in the central regions are very low (22 $\pm$ 12 and 7 $\pm$ 21 km/s), indicating no significant relative motion between the brightest cluster galaxy (BCG) and the intracluster medium (ICM). Given that the central region includes the southward extending cool gas tail, this result disfavors the ``cooling-wake'' scenario and instead supports an AGN-uplift origin. We find that the nonthermal pressure fraction decreases with radius, from $P_{\rm NT}/P_{\rm T}\approx2\%$ in the core to $\sim0.6\%$ at 330 kpc, suggesting that the northern ICM of A1795 is largely quiescent. Two-temperature and split energy-band (2--4 keV and 6--7 keV) fits identify two gas phases within the central $<1.5'$ region, providing strong evidence for multiphase gas in the cluster core. We detect a $\sim14\%$ resonant suppression of the optically thick Fe XXV $w$ line in the center. Additionally, we observe a significant excess in the Fe XXV $y$ line-flux relative to models. Accounting for uncertainties in the atomic data reduces this discrepancy, suggesting that atomic data uncertainties may contribute to the observed residual flux.

astro-ph.CO

A Fast, Hot Wind from a Nuclear Starburst

Galaxies with intense star formation often host multiphase, galaxy-scale winds powered by supernovae and fast stellar winds. These are strong enough to disrupt the star-forming interstellar medium, and they chemically enrich the surrounding circumgalactic medium. However, their launching mechanism remains unknown. Here we show that thermal gas pressure is sufficient to drive the multiphase wind in the prototypical starburst galaxy M82. Using a high energy-resolution ($\Delta E = 4.5$ eV) XRISM Resolve spectrum, including detections of FeXXV 6.7 keV, ArXVII 3.1 keV, and SXVI 2.6 keV, we measure the temperature ($T = 2.3^{+0.5}_{-0.2} \times 10^7$ K) and mass ($M \approx 6 \pm 2 \times 10^5$ M$_\odot$) of the hot gas in the starburst and provide the first direct measurement of its line-of-sight velocity dispersion ($\sigma = 595^{+464}_{-128}$ km s$^{-1}$). These values are consistent with a freely-expanding wind exceeding the galactic escape velocity. The size of the FeXXV-emitting region suggests a hot gas outflow rate of $\dot{M} \approx 4$ M$_\odot$ yr$^{-1}$, carrying a total energy of $\dot{E} \approx 2 \times 10^{42}$ erg s$^{-1}$. This is sufficient to drive the molecular, atomic, and ionized outflows while transporting up to $\approx 2$ M$_\odot$ yr$^{-1}$ of hot gas to the intergalactic medium. The estimated supernova rate implies that $\approx$ 60% of the supernova energy must be thermalized in hot gas. Our results suggest that additional driving mechanisms, such as cosmic-ray pressure, are not required to launch the wind.

astro-ph.GA

High Spectral Resolution X-ray Observations of the Evolved Supermassive Stellar Binary System $\eta$ Carinae - Iron K$\alpha$ Band Profile Revealed with XRISM

The supermassive binary system, $\eta$ Carinae, is experiencing enormous wind-driven mass loss at a rate unparalleled in the rest of the Galaxy. Their wind-wind collision (WWC) continuously produces shock heated, X-ray emitting plasmas. The XRISM X-ray observatory observed the system in 2023 and 2024 when the X-ray emission began to increase toward periastron passage in 2025. This manuscript reports unprecedentedly high-resolution X-ray spectra in the iron K$\alpha$ band between 6.2 and 7.1 keV, obtained with the Resolve X-ray microcalorimeter. The hydrogen-like (Ly$\alpha$) and helium-like (He$\alpha$) lines reveal three velocity components. Two of them are broadened with maximum velocities of 2000-3000 km/s, likely originating from the post-shock companion wind. The other is relatively narrow, with a Gaussian broadening of only ~290 km/s in 1 sigma, which may originate from the post-shock companion wind at the WWC stagnation point or penetrating the primary wind. The iron fluorescent lines exhibit a moderate blueshift and broadening with velocities at 100-200 km/s, consistent with the primary wind's velocity field. The spectra also confirm a Compton shoulder of the He$\alpha$ line complex for the first time. Both fluorescing and scattering spectral profiles indicate that the binary system is seen from the companion side during these observations. The flux ratio of the Compton scattering emission to the fluorescent line suggests substantial hydrogen depletion of the primary wind, expected from CNO-cycled hydrogen nuclear fusion gas.

astro-ph.HE

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of $\sim 10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7--10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5--7.0 keV), we resolved the inner-shell lines of Fe XIX--XXIV as well as the outer-shell lines of Fe XXV--XXVI. These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1--10 keV (roughly 10--100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

astro-ph.SR

XRISM Observations of Accretion Disk Corona in Cyg X-2

We present the high-resolution X-ray spectrum of the Z-source Cygnus X-2, obtained with X-Ray Imaging and Spectroscopy Mission (XRISM). The observations have enabled a precise characterization of the Fe-K emission lines from the accretion disk corona (ADC) and a possible detection of an ultra-fast outflow (UFO). The ADC component has at least two distinct regions. The Fe-K emission lines are remarkably broad, with a velocity dispersion of $\sigma_v=2300^{+900}_{-700}$~km~s$^{-1}$. This can be larger than what was observed in previous Chandra observations ($1120\pm870$~km~s$^{-1}$) and recent XRISM observations of the similar Z-source GX 340+0 (360--800~km~s$^{-1}$). Furthermore, we marginally detect a blueshifted absorption feature, which we identify as either \ion{Fe}{26} or \ion{Fe}{25}, with outflow velocities of $-0.29c$ or $-0.26c$, respectively. The mass loss rate is $\dot{M}\sim10^{-8}M_\odot\,\mathrm{yr}^{-1}$. Our findings suggest that the ADC in Cyg X-2 has a kinematically active environment with a high degree of turbulence and kinetic energy.

astro-ph.HE