SearcharxivSearch

arXiv subjects

F. Cappella

Publications and source records attributed to F. Cappella.

At least 19 recordsLinked to original sources

Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment

The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CE$\nu$NS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this work, the cryogenic target-detector module for the NUCLEUS Technical Run was developed and commissioned at the Technical University of Munich. The module comprises four gram-scale CaWO$_4$ detectors, each equipped with two Transition Edge Sensors (TES), providing a total target mass of 6.96 g. We present the design, integration, detector characterization, and X-ray-based energy calibration of these detectors. Across six characterized detectors, a mean baseline resolution of $\overline{\sigma}_{\mathrm{BL}} = (2.79 \pm 0.60)\,\mathrm{eV}$ was achieved. The best-performing detector reached $\sigma_{\mathrm{BL}} = (2.16 \pm 0.02_{\mathrm{stat}})\,\mathrm{eV}$, surpassing the design goal by a factor of two and representing a state-of-the-art result for a cryogenic CaWO$_4$ detector. The target detector module was successfully operated simultaneously with the surrounding Cryogenic Outer Veto, which consists of six kg-scale Ge detectors for background discrimination, showing no measurable cross-talk. These results demonstrate the readiness of the target-detector system for the NUCLEUS Technical Run at Chooz and mark a key milestone in the development of cryogenic detectors for reactor-CE$\nu$NS measurements.

physics.ins-det

Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment

Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving the best sensitivity for this kind of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information on different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. With both techniques at the same time, we obtained a baseline resolution of 2.94 $\pm$ 0.05 (stat) eV using a CaWO4 based detector, achieving a promising result in view of the first run of NUCLEUS at the experimental site.

physics.ins-det

Prospect of the NUCLEUS Experiment at Chooz for Coherent Elastic Neutrino-Nucleus Scattering and New Physics Searches

The NUCLEUS experiment aims to measure coherent elastic neutrino-nucleus scattering (CE$\nu$NS) at unprecedentedly low nuclear recoil energies using gram-scale cryogenic calorimeters operated at the Chooz nuclear power plant in France. Access to recoil energies at the $\mathcal{O}(10~\mathrm{eV})$ scale enables CE$\nu$NS studies at extremely low momentum transfer and provides enhanced sensitivity to new physics. In this work, we present sensitivity projections for the upcoming NUCLEUS technical and physics runs, incorporating a data-driven treatment of the low-energy excess (LEE) observed during commissioning. We develop a likelihood framework that exploits reactor-power variation to disentangle signal and background in a low signal-to-background regime and to assess the impact of the dominant systematic uncertainties. For the Technical Run with a 7 g CaWO$_4$ target, we find competitive sensitivity to several scenarios beyond the Standard Model, which do not require a CE$\nu$NS observation. For the Physics Run, assuming complete suppression of the LEE, we project a 4.7 $\sigma$ observation of CE$\nu$NS with a statistical precision of about 20 % in 1 year, enabling a determination of the weak mixing angle at the lowest momentum transfer probed to date with CE$\nu$NS and leading CE$\nu$NS-based constraints on the neutrino charge radius and new mediator models.

hep-ex

Characterization of the Low Energy Excess using a NUCLEUS Al$_{2}$O$_{3}$ detector

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $(-0.59 \pm 0.06)$, when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.

physics.ins-det

Electron spectral shape of the third-forbidden $\beta$-decay of $^{87}$Rb measured using a Rb$_2$ZrCl$_6$ crystal scintillator

In recent years, interest in experimental studies of $\beta$-decay electron spectra -- often referred to as $\beta$ spectra -- has been growing. This is particularly true for $\beta$ transitions where the electron spectra are sensitive to the effective value of the weak axial coupling, $g_{\rm A}$. Such measurements serve as important benchmarks for nuclear physics calculations and can also be used to characterize background in astroparticle physics experiments. In this work, a dedicated experiment has been carried out to investigate the spectral shape of the third-forbidden $^{87}$Rb $\beta$-decays, with the goal of estimating the effective $g_{\rm A}$ value for this transition and of deriving the T$_{1/2}$ value. This was done by comparing the experimental spectral shape with the estimates from various phenomenological models. The $^{87}$Rb source was embedded directly within the detector material of a new Rb$_2$ZrCl$_6$ crystal scintillator; the data taking was performed deep underground at Gran Sasso National Laboratory. The obtained experimental half-life value for the studied process is T$_{1/2} = 5.08(13) \times$ 10$^{10}$ yr; while a $g_{\rm A}$ value in the range 0.4 to 0.6 is obtained when accounting for uncertainties and depending on the model adopted as discussed in detail in the text.

nucl-ex

Observation of two nuclear recoil peaks induced by neutron capture on Al2O3

We report the observation of two nuclear recoil peaks induced by neutron capture on aluminum in a cryogenic Al$_2$O$_3$ detector developed by the NUCLEUS collaboration for the detection of reactor neutrinos via coherent elastic neutrino-nucleus (CEvNS) process. Data collected at the Technical University of Munich in 2024 with a $^{252}$Cf source reveal a main recoil line at 1145 eV from single-$\gamma$ de-excitation of $^{28}$Al and a newly observed structure near 575 eV originating from several two-$\gamma$ cascades. The latter constitutes the first direct measurement of a nuclear recoil line induced by multi-$\gamma$ cascades. It is predicted by our simulations when the recoiling nucleus has time to stop before the emission of the next $\gamma$-ray in the cascade. These results demonstrate the potential performance of the CRAB (Calibration Recoil for Accurate Bolometry) method for in situ nuclear recoil calibration and highlight the importance of accurately modeling recoil stopping and nuclear de-excitation times in cryogenic detectors of CEvNS and dark matter interactions.

physics.ins-det

Scintillating properties of Cs${_2}$ZrCl${_6}$ crystals in the temperature range of 5-300 K

A new comprehensive study on the Cs${_2}$ZrCl${_6}$ (CZC) crystal scintillating properties under different types of irradiation was performed over a wide temperature range from 5 to 300 K. The light yield (LY) at room temperature (RT), measured under irradiation by 662 keV $\gamma$ quanta of $^{137}$Cs, was evaluated to be 53,300 $\pm$ 4,700 photons/MeV corresponding to approximately 71% of its estimated absolute value. The maximum light emission was observed in the temperature interval 135-165 K, where the LY reached 56,900 photons/MeV and 19,700 photons/MeV for $\gamma$ quanta and $\alpha$ particles, respectively. The quenching factor (QF) for $\alpha$ particles increases smoothly from QF = 0.30 at RT to QF = 0.36 at 135 K. The shape of scintillation pulses induced by $\alpha$ particles is characterized by three time-constants (0.3, 2.5 and 11.8 $\mu$s at RT), whereas the average pulse of $\gamma$ induced events is characterized by two time-constants (1.3 and 11.5 $\mu$s at RT). At the same time, scintillating properties and pulse-shape discrimination capability of the CZC exhibit an acute deterioration at temperatures below 135 K. The optimal operating conditions to maximize the scintillating performance of undoped CZC crystals are discussed.

physics.ins-det

Particle background characterization and prediction for the NUCLEUS reactor CE$\nu$NS experiment

NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino-Nucleus Scattering (CE$\nu$NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE$\nu$NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE$\nu$NS signal region of interest between 10 and 100 eV, a total particle background rate of $\sim$ 250 d$^{-1}$kg$^{-1}$keV$^{-1}$ is expected in the CaWO$_4$ target detectors. This corresponds to a signal-to-background ratio $\gtrsim$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE$\nu$NS.

physics.ins-det

Commissioning of the NUCLEUS Experiment at the Technical University of Munich

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO$_4$ targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW$_{\text{th}}$ reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.

hep-ex

Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source

Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677\,eV to 6.5\,keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).

physics.ins-det

The CRAB facility at the TU Wien TRIGA reactor: status and related physics program

The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The CRAB method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. A crown of BaF$_2$ detectors installed outside the dewar enables coincident detection of the high-energy $\gamma$ escaping the target crystal after neutron capture. After the presentation of all components of the setup we report the analysis of first commissioning data with a CaWO$_4$ detector of the \NUCLEUS experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $^{187}$W. Finally, we present the first evidence of neutron-capture induced coincidences between $\gamma$-detectors and a cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO$_4$, Al$_2$O$_3$, Ge and Si.

physics.ins-det

Double-beta decay of $^{150}$Nd to excited levels of $^{150}$Sm

The $2\nu2\beta$ decay of $^{150}$Nd to the first excited 740.5 keV $0^{+}_{1}$ level of $^{150}$Sm was measured over 5.845 yr with the help of a four-crystal low-background HPGe $\gamma$ spectrometry system in the underground low-background laboratory STELLA of LNGS-INFN. A 2.381 kg highly purified Nd-containing sample was employed as the decay source. The expected de-excitation gamma-quanta of the $0^{+}_{1}$ level with energies 334.0 keV and 406.5 keV were observed both in one-dimensional spectrum and in coincidence data resulting in the half-life $T_{1/2}=[0.83^{+0.18}_{-0.13}\mathrm{(stat)}^{+0.16}_{-0.19}\mathrm{(syst)}]\times 10^{20}$ yr. Interpreting an excess of the 334.0-keV peak area as an indication of the $2\beta$ decay of $^{150}$Nd to the 334.0 keV $2^+_1$ excited level of $^{150}$Sm with a half-life of $T_{1/2}=[1.5^{+2.3}_{-0.6}\mathrm{(stat)}\pm 0.4\mathrm{(syst)}]\times10^{20}$ yr, the $2\nu2\beta$ half-life of $^{150}$Nd for the transition to the 0$^{+}_{1}$ level is $T_{1/2}=[1.03^{+0.35}_{-0.22}\mathrm{(stat)}^{+0.16}_{-0.19}\mathrm{(syst)}]\times 10^{20}$ yr, in agreement with the previous experiments. Both half-life values reasonably agree with the theoretical calculations in the framework of proton-neutron QRPA with isospin restoration combined with like nucleon QRPA for description of excited states in the final nuclei. For $2\nu2\beta$ and $0\nu2\beta$ transitions of $^{150}$Nd and $^{148}$Nd to several excited levels of $^{150}$Sm and $^{148}$Sm, limits were set at level of $T_{1/2}>10^{20}-10^{21}$ yr.

nucl-ex

Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures

With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low $(6.22 \pm 0.07)$ eV baseline resolution on a gram-scale CaWO$_4$ cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.

physics.ins-det

Final results of the measurement to search for rare decays of naturally occurring osmium isotopes with ultra-low background gamma-ray spectrometry

A long-term measurement was conducted to search for $\alpha$, double-$\alpha$ and double-$\beta$ decays with $\gamma$ quanta emission in naturally occurring osmium isotopes. This study took advantage of two ultra-low background HPGe detectors and one ultra-low background BEGe detector at the Gran Sasso National Laboratory (LNGS) of the INFN. Over almost 5 years of data were taken using high-purity osmium samples of approximately 173 g. The half-life limits set for a decays of $^{184}$Os to the first $2^+$ 103.6 keV excited level of $^{180}$W ($T_{1/2} > 9.3 \times 10^{15}$ yr) and of $^{186}$Os to the first $2^+$ 100.1 keV of $^{182}$W ($T_{1/2} > 4.8 \times 10^{17}$ yr) exceed substantially the present theoretical predictions that are at level of $T_{1/2} \sim (0.6 - 3) \times 10^{15}$ yr for $^{184}$Os and $T_{1/2} \sim (0.3 - 2) \times 10^{17}$ yr for $^{186}$Os. New half-life limits on the 2EC and EC$\beta^+$ decay of $^{184}$Os to the ground and excited levels of $^{184}$W were set at level of $T_{1/2} > 10^{16} - 10^{17}$ yr; a lower limit on the $2\beta^-$ decay of $^{192}$Os to the $2^+$ 316.5 keV excited level of $^{192}$Pt was estimated as $T_{1/2} > 6.1 \times 10^{20}$ yr. The half-life limits for $2\alpha$ decay of $^{189}$Os and $^{192}$Os were set for the first time at level of $T_{1/2} > 10^{20}$ yr.

nucl-ex

Do we understand the internal spaces of second quantized fermion and boson fields, with gravity included? Relation with strings theories

The article proposes the description of internal spaces of fermion (quarks and leptons and antiquarks and antileptons) and boson (photons, weak bosons, gluons, gravitons and scalars) second quantized fields in a unique way if they all are massless. The internal spaces are described by ``basis vectors'', which are the superposition of odd (for fermions) and even (for bosons) products of the operators $\gamma^ {a}$. For an arbitrary symmetry $SO(d-1,1)$ of the internal spaces, it is the number of fermion fields (they appear in families and have their Hermitian conjugated partners in a separate group) equal to the number of boson fields (they appear in two orthogonal groups), manifesting a kind of supersymmetry, which differ of the string supersymmetry. On the assumption that fermions and bosons are active (they have momenta different from zero) only in $d=(3+1)$ ordinary space-time, bosons present vectors if they carry the space index $\mu=(0,1,2,3)$, and present scalars if they carry the index $\sigma \ge 5$. The author discusses this theory's latest achievements, with a trial to understand whether the extension to strings or to odd-dimensional spaces can lead to a new kind of supersymmetry. This model, named {\it spin-charge-family} theory, manifests in a long series of papers on the phenomenological success of the theory in elementary particle physics and cosmology.

physics.gen-ph

A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures

Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in keeping the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.

physics.ins-det

Study of collision and $\gamma$-cascade times following neutron-capture processes in cryogenic detectors

The emission of $\gamma$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay between the development in time of the de-excitation $\gamma$-cascade of the target nucleus and that of the associated atomic collisions in matter. We present detailed simulations coupling the FIFRELIN code for the description of the $\gamma$-cascades and the IRADINA code for the modelling of the fast atomic movements in matter. Nuclear recoil spectra are predicted, and made available to the community, for concrete cases of Al$_2$O$_3$, Si, Ge and CaWO$_4$ crystals exposed to a low intensity beam of thermal neutrons. We find that timing effects cause new calibration peaks to emerge in the recoil spectra and also impact the shape of the continuous recoil distribution. We discuss how they could give access to a rich physics program, spanning the accurate study of the response of cryogenic detectors in the sub-keV range, tests of solid state physics simulations and tests of nuclear models.

physics.ins-det