Searcharxiv⌕ Search

arXiv subjects

F. G. Schuckman II

Publications and source records attributed to F. G. Schuckman II.

10 recordsLinked to original sources

Measurement of the muon flux at SNOLAB using the DEAP-3600 experiment

A direct measurement of the muon flux at SNOLAB is performed using the DEAP-3600 experiment, located 2 km underground at SNOLAB near Sudbury, Canada. Primarily designed for the direct detection of weakly interacting massive particles (WIMPs), a dark matter candidate, DEAP-3600 consists of an inner spherical acrylic vessel containing a liquid argon target; this vessel is enclosed within a steel shell which is submerged in an instrumented water tank, serving as a muon veto for the dark matter search. The muon flux measurement is performed using a cut-and-count analysis of events observed in the muon veto detector and of events which are coincident between the muon veto and the liquid argon target. The requirement that muons traverse both the water and liquid argon minimizes instrumental backgrounds and systematic uncertainties. Using data collected from November 2016 to March 2020, the muon flux is measured by this coincidence analysis to be $(3.71 \pm 0.25_{\textrm{stat}} \pm 0.09_{\textrm{sys}}) \times 10^{-10}\, μ/$cm$^2$/s. The standalone measurement using muon veto data only is compatible within uncertainties. Both measurements agree with the previous result by the SNO experiment and with simulations carried out using the MUTE software. These results provide an important benchmark for future rare-event searches at the SNOLAB facility.

hep-ex↗

First evidence of neutrino absorption on argon using $^{8}$B solar neutrinos in DEAP-3600

We report experimental evidence for electron neutrino charged-current interactions (neutrino absorption, CC $ν_e$) from $^{8}$B solar neutrinos on $^{40}$Ar using an exposure of ($7.29 \pm 0.05$) tonne$\cdot$years in the DEAP-3600 detector. A region of interest (ROI) of 10.5-13.0 MeV reconstructed energy calibrated on single-peak events, corresponding to incident neutrino energy in 12.0-14.5 MeV, is used for this measurement. We observe 5 single-peak and 1 double-peak neutrino-like events consistent with the $^{8}$B solar neutrino energy spectrum in the ROI after correcting for nonlinearities in the detector response at high energies. With an expected background of $0.48~^{+0.16}_{-0.15}$ events, the data correspond to a significance of $4.0\,σ$ with respect to the background-only hypothesis. We report an energy-averaged cross section of $(4.0~^{+2.0}_{-1.6}~\mathrm{(stat)}~^{+0.8}_{-0.7}~\mathrm{(sys)})\times 10^{-41}\,\mathrm{cm}^2$ in the ROI for the CC $ν_{e}$ signal, a factor $(2.4~^{+1.3}_{-1.0})$ higher than predicted by Bhattacharya, Goodman and García (2009).

hep-ex↗

Dark Matter Search with the DEAP-3600 Detector using the Profile Likelihood Ratio Method

We present here a search for WIMP dark matter using 790.8 live-days of data collected with 3269 kg of liquid argon (1266 kg fiducial) by the DEAP-3600 detector at SNOLAB, using the Profile Likelihood Ratio method. The likelihood model is based on three parameters: estimated energy, pulse-shape discrimination parameter, and reconstructed position within the detector. Using this method, the expected signal sensitivity of DEAP-3600 benefits from an increased fiducial volume and improved event selection acceptance. Alpha-decays from a small number of dust particulates circulating within the liquid argon target are the dominant source of background events and limit the sensitivity of this search. This result provides improved exclusion upper limits on the WIMP-nucleon spin-independent cross section on liquid argon for WIMP masses between 20 GeV/$c^{2}$ and 100 GeV/$c^{2}$. At 100 GeV/$c^{2}$ the observed limit is 3.4 $\times$ 10$^{-45}$ cm$^2$ at 90% confidence level.

hep-ex↗

Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $α$-Particles in Liquid Argon using DEAP-3600 Data

The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace amounts in the DEAP-3600 detector and quantified the uncertainty of extrapolating the quenching factor to the low-energy region.

physics.ins-det↗

Direct Measurement of the $^{39}$Ar Half-life from 3.4 Years of Data with the DEAP-3600 Detector

The half-life of $^{39}$Ar is measured using the DEAP-3600 detector located 2 km underground at SNOLAB. Between 2016 and 2020, DEAP-3600 used a target mass of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere in a direct-detection dark matter search. Such an argon mass also enables direct measurements of argon isotope properties. The decay of $^{39}$Ar in DEAP-3600 is the dominant source of triggers by two orders of magnitude, ensuring high statistics and making DEAP-3600 well-suited for measuring this isotope's half-life. Use of the pulse-shape discrimination technique in DEAP-3600 allows powerful discrimination between nuclear recoils and electron recoils, resulting in the selection of a clean sample of $^{39}$Ar decays. Observing over a period of 3.4 years, the $^{39}$Ar half-life is measured to be $(302 \pm 8_{\rm stat} \pm 6_{\rm sys})$ years. This new direct measurement suggests that the half-life of $^{39}$Ar is significantly longer than the accepted value, with potential implications for measurements using this isotope's half-life as input.

nucl-ex↗

Improved Sensitivity of the DRIFT-IId Directional Dark Matter Experiment using Machine Learning

We demonstrate a new type of analysis for the DRIFT-IId directional dark matter detector using a machine learning algorithm called a Random Forest Classifier. The analysis labels events as signal or background based on a series of selection parameters, rather than solely applying hard cuts. The analysis efficiency is shown to be comparable to our previous result at high energy but with increased efficiency at lower energies. This leads to a projected sensitivity enhancement of one order of magnitude below a WIMP mass of 15 GeV c$^{-2}$ and a projected sensitivity limit that reaches down to a WIMP mass of 9 GeV c$^{-2}$, which is a first for a directionally sensitive dark matter detector.

astro-ph.IM↗

New Concept for Electron Beam-Dump Experiment Utilizing Directional WIMP Detector

Light dark matter in the context of dark sector theories is an attractive candidate for the dark matter thought to make up the bulk of the mass of our universe. We explore here the possibility of using a low-pressure, negative-ion, time projection chamber detector to search for light dark matter behind the beam dump of an electron accelerator. The sensitivity of a 10 m long detector is several orders of magnitude better than existing limits. This sensitivity includes regions of parameter space where light dark matter is predicted to have a required relic density consistent with measured dark matter density. Backgrounds at shallow depth will need to be considered carefully. However, several signatures exist, including a powerful directional signature, which will allow a detection even in the presence of backgrounds.

astro-ph.IM↗

Measurement of directional range components of nuclear recoil tracks in a fiducialised dark matter detector

We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this measurement, neutron-induced nuclear recoil tracks were generated by exposing the detector to $^{252}$Cf source from different directions. Using these events, the sensitivity of the detector to the expected axial directional signatures were investigated as the neutron source was moved from one detector axis to another. Results obtained from these measurements show clear sensitivity of the DRIFT detector to the axial directional signatures in this fiducialization gas mode.

physics.ins-det↗

Low Threshold Results and Limits from the DRIFT Directional Dark Matter Detector

We present results from a 54.7 live-day shielded run of the DRIFT-IId detector, the world's most sensitive, directional, dark matter detector. Several improvements were made relative to our previous work including a lower threshold for detection, a more robust analysis and a tenfold improvement in our gamma rejection factor. After analysis, no events remain in our fiducial region leading to an exclusion curve for spin-dependent WIMP-proton interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our previous work. We also present results from a 45.4 live-day unshielded run of the DRIFT-IId detector during which 14 nuclear recoil-like events were observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08 events per day is consistent with detection of ambient, fast neutrons emanating from the walls of the Boulby Underground Science Facility.

astro-ph.IM↗

First measurement of nuclear recoil head-tail sense in a fiducialised WIMP dark matter detector

Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time projection chamber. In this new operational mode, the distance between each event vertex and the readout plane is determined by the measurement of minority carriers produced by adding a small amount of oxygen to the nominal CS$_{2}$ + CF$_{4}$ target gas mixture. The CS$_2$ + CF$_4$ + O$_2$ mixture has been shown to enable background-free operation at current sensitivities. Sulfur, fluorine, and carbon recoils were generated using neutrons emitted from a $^{252}$Cf source positioned at different locations around the detector. Measurement of the relative energy loss along the recoil tracks allowed the track vector sense, or the so-called head-tail asymmetry parameter, to be deduced. Results show that the previously reported observation of head-tail sensitivity in pure CS$_{2}$ is well retained after the addition of oxygen to the gas mixture.

physics.ins-det↗