Searcharxiv⌕ Search

arXiv subjects

F. Martinez-Mckinney

Publications and source records attributed to F. Martinez-Mckinney.

4 recordsLinked to original sources

Summary of quality control (QC) of ATLAS18 production ITk strip sensors

To address the demanding operational requirements of the High-Luminosity upgrade of the Large Hadron Collider (HL-LHC), the ATLAS experiment is replacing its current Inner Detector with a new all-silicon Inner Tracker (ITk). The ITk will feature an active area of 165 m2, with its outer tracking layers populated by approximately 18,000 ATLAS18 n+-in-p silicon strip sensors. The silicon sensors, available in eight geometries tailored to two barrel and six endcap types, respectively, are designed to tolerate fluences of up to 1.6 x 10^15 neq/cm2 and ionizing doses of 66 Mrad. A comprehensive, multi-year Quality Control (QC) program is underway across multiple international institutes to evaluate these ITk strip sensors for mechanical and electrical conformity. The QC process includes IV/CV characterization, full strip tests, long-term current stability monitoring, visual inspection, and metrology tests. To manage the high throughput of about 500 sensors per month, the collaboration has implemented standardized test procedures, software packages for data monitoring and integrity checks, unified data formats, and automated analysis tools. The standardization ensures consistent pass/fail evaluation and centralized data handling that enables effective identification of trends and anomalies at all sites during the production. This contribution presents an overview of the ITk strip sensor production and QC framework, along with key findings throughout the whole production, such as charge-up of sensors, stability of the leakage currents, nonrecoverable IV breakdown, and low inter-strip isolation within wafers. It provides insights into sensor yield, quality trends, and reviews specific case studies, such as p-stop doping non-uniformity. Over 91% of the production, totaling over 590 batches, were tested and accepted. Six batches were rejected. These account for 2.8% of the total tested sensors.

physics.ins-det↗

First Test Results of the Trans-Impedance Amplifier Stage of the Ultra-fast HPSoC ASIC

We present the first results from the HPSoC ASIC designed for readout of Ultra-fast Silicon Detectors. The 4-channel ASIC manufactured in 65 nm CMOS by TSMC has been optimized for 50 um thick AC-LGAD. The evaluation of the analog front end with \b{eta}-particles impinging on 3x3 AC-LGAD arrays (500 um pitch, 200x200 um2 metal) confirms a fast output rise time of 600 ps and good timing performance with a jitter of 45 ps. Further calibration experiments and TCT laser studies indicate some gain limitations that are being investigated and are driving the design of the second-generation pre-amplification stages to reach a jitter of 15 ps.

physics.ins-det↗

Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.

physics.ins-det↗

Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

physics.ins-det↗