SearcharxivSearch

arXiv · 2607.14691

Summary of quality control (QC) of ATLAS18 production ITk strip sensors

Abstract

To address the demanding operational requirements of the High-Luminosity upgrade of the Large Hadron Collider (HL-LHC), the ATLAS experiment is replacing its current Inner Detector with a new all-silicon Inner Tracker (ITk). The ITk will feature an active area of 165 m2, with its outer tracking layers populated by approximately 18,000 ATLAS18 n+-in-p silicon strip sensors. The silicon sensors, available in eight geometries tailored to two barrel and six endcap types, respectively, are designed to tolerate fluences of up to 1.6 x 10^15 neq/cm2 and ionizing doses of 66 Mrad. A comprehensive, multi-year Quality Control (QC) program is underway across multiple international institutes to evaluate these ITk strip sensors for mechanical and electrical conformity. The QC process includes IV/CV characterization, full strip tests, long-term current stability monitoring, visual inspection, and metrology tests. To manage the high throughput of about 500 sensors per month, the collaboration has implemented standardized test procedures, software packages for data monitoring and integrity checks, unified data formats, and automated analysis tools. The standardization ensures consistent pass/fail evaluation and centralized data handling that enables effective identification of trends and anomalies at all sites during the production. This contribution presents an overview of the ITk strip sensor production and QC framework, along with key findings throughout the whole production, such as charge-up of sensors, stability of the leakage currents, nonrecoverable IV breakdown, and low inter-strip isolation within wafers. It provides insights into sensor yield, quality trends, and reviews specific case studies, such as p-stop doping non-uniformity. Over 91% of the production, totaling over 590 batches, were tested and accepted. Six batches were rejected. These account for 2.8% of the total tested sensors.

Explore related subjects

Keep this discovery

BibTeXRIS

P. Federičováa, A. Affolder, K. Affolder, A. Awais, G. A. Beck, A. J. Bevan, Z. Chen, J. Dandoy, I. Dawson, V. Fadeyev, J. Fernandez-Tejero, E. C. Hill, S. Hirose, L. Hommels, T. Ivison, C. Jessiman, K. Kariyapperuma, S. Katznelson, J. Keller, C. T. Klein, T. Koffas, I. Kopsalis, J. Kozáková, J. Kroll, M. Kůtová, J. Kvasnička, K. Maeyama, R. R. Marcelo Gregorio, F. Martinez-Mckinney, M. Mikeštíková, P. S. Miyagawa, L. Morelos-Zaragoza, K. Nakamura, Q. Paddock, K. Sato, E. Staats, P. Tůma, M. Ullan, Y. Unno, Y. Zhao, S. C. Zenz. 2026-07-16. Summary of quality control (QC) of ATLAS18 production ITk strip sensors. https://doi.org/10.1016/j.nima.2026.171716

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det