Searcharxiv⌕ Search

arXiv subjects

Fangjun Lu

Publications and source records attributed to Fangjun Lu.

At least 37 records · Page 2Linked to original sources

A giant glitch from the magnetar SGR J1935+2154 before FRB 200428

Fast radio bursts (FRBs) are short pulses observed in radio frequencies usually originating from cosmological distances. The discovery of FRB 200428 and its X-ray counterpart from the Galactic magnetar SGR J1935+2154 suggests that at least some FRBs can be generated by magnetars. However, the majority of X-ray bursts from magnetars are not associated with radio emission. The fact that only in rare cases can an FRB be generated raises the question regarding the special triggering mechanism of FRBs. Here we report a giant glitch from SGR J1935+2154, which occurred approximately $3.1\pm2.5$\,day before FRB 200428, with $Δν=19.8\pm1.4$ {\rm $μ$Hz} and $Δ\dotν=6.3\pm1.1$\,pHz s$^{-1}$. The corresponding spin-down power change rate $Δ\dotν/\dotν$ is among the largest in all the detected pulsar glitches. The glitch contains a delayed spin-up process that is only detected in the Crab pulsar and the magnetar 1E 2259+586, a large persistent offset of the spin-down rate, and a recovery component which is about one order of magnitude smaller than the persistent one. The temporal coincidence between the glitch and FRB 200428 suggests a physical connection between the two. The internally triggered giant glitch of the magnetar likely altered the magnetosphere structure dramatically in favour of FRB generation, which subsequently triggered many X-ray bursts and eventually FRB 200428 through additional crustal cracking and Alfvén wave excitation and propagation.

astro-ph.HE↗

The 100-m X-ray Test Facility at IHEP

The 100-m X-ray Test Facility of the Institute of High Energy Physics (IHEP) was initially proposed in 2012 for the test and calibration of the X-ray detectors of the Hard X-ray Modulation Telescope (HXMT) with the capability to support future X-ray missions. The large instrument chamber connected with a long vacuum tube can accommodate the X-ray mirror, focal plane detector and other instruments. The X-ray sources are installed at the other end of the vacuum tube with a distance of 105 m, which can provide an almost parallel X-ray beam covering 0.2$\sim$60 keV energy band. The X-ray mirror modules of the Einstein Probe (EP) and the enhanced X-ray Timing and Polarimetry mission (eXTP) and payload of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) have been tested and calibrated with this facility. It has been also used to characterize the focal plane camera and aluminum filter used on the Einstein Probe. In this paper, we will introduce the overall configuration and capability of the facility, and give a brief introduction of some calibration results performed with this facility.

astro-ph.IM↗

The observation of quantum fluctuations in a kagome Heisenberg antiferromagnet

The search for the experimental evidence of quantum spin liquid (QSL) states is critical but extremely challenging, as the quenched interaction randomness introduced by structural imperfection is usually inevitable in real materials. YCu$_3$(OH)$_{6.5}$Br$_{2.5}$ (YCOB) is a spin-1/2 kagome Heisenberg antiferromagnet (KHA) with strong coupling of $\langle J_1\rangle\sim$ 51 K but without conventional magnetic freezing down to 50 mK $\sim$ 0.001$\langle J_1\rangle$. Here, we report a Br nuclear magnetic resonance (NMR) study of the local spin susceptibility and dynamics on the single crystal of YCOB. The temperature dependence of NMR main-line shifts and broadening can be well understood within the frame of the KHA model with randomly distributed hexagons of alternate exchanges, compatible with the formation of a randomness-induced QSL state at low temperatures. The in-plane spin fluctuations as measured by the spin-lattice relaxation rates ($1/T_1$) exhibit a weak temperature dependence down to $T$ $\sim$ 0.03$\langle J_1\rangle$. Our results demonstrate that the majority of spins remain highly fluctuating at low temperatures despite the quenched disorder in YCOB.

cond-mat.str-el↗

An Insight-HXMT view of the mHz quasi-regular modulation phenomenon in the black hole X-ray binary 4U 1630-47

Here we report the spectral-timing results of the black hole X-ray binary 4U 1630-47 during its 2021 outburst using observations from the Hard X-ray Modulation Telescope. Type-C quasi-periodic oscillations (QPOs) in 1.6--4.2 Hz and quasi-regular modulation (QRM) near 60 mHz are detected during the outburst. The mHz QRM has a fractional rms of 10%--16% in the 8--35 keV energy band with a Q factor (frequency/width) of 2--4. Benefiting from the broad energy band of hxmt, we study the energy dependence of the 60 mHz QRM in 1--100 keV for the first time. We find that the fractional rms of the mHz QRM increases with photon energy, while the time lags of the mHz QRM are soft and decrease with photon energy. Fast recurrence of the mHz QRM, in a timescale of less than one hour, has been observed during the outburst. During this period, the corresponding energy spectra moderately change when the source transitions from the QRM state to the non-QRM state. The QRM phenomena also shows a dependence with the accretion rate. We suggest that the QRM could be caused by an unknown accretion instability aroused from the corona.

astro-ph.HE↗

Uniaxial stress effect on the quasi-one-dimensional Kondo lattice CeCo$_2$Ga$_8$

Quantum critical phenomena in the quasi-one-dimensional limit remains an open issue. We report the uniaxial stress effect on the quasi-one-dimensional Kondo lattice CeCo$_2$Ga$_8$ by electric transport and AC heat capacity measurements. CeCo$_2$Ga$_8$ is speculated to sit in close vicinity but on the quantum-disordered side of a quantum critical point. Upon compressing the ${c}$ axis, parallel to the Ce-Ce chain, the onset of coherent Kondo effect is enhanced. In contrast, the electronic specific heat diverges more rapidly at low temperature when the intra-chain distance is elongated by compressions along {a} or {b} axes. These results suggest that a tensile intra-chain strain ($\varepsilon_c >0$) pushes CeCo$_2$Ga$_8$ closer to a quantum critical point, while a compressive intra-chain strain ($\varepsilon_c <0$) likely causes departure. Our work provides a rare paradigm of manipulation near a quantum critical point in a quasi-1D Kondo lattice by uniaxial stress, and paves the way for further investigations on the unique feature of quantum criticality in the quasi-1D limit.

cond-mat.str-el↗

Insight-HXMT dedicated 33-day observation of SGR J1935+2154 II. Burst Spectral Catalog

Since April 28, 2020, Insight-HXMT has implemented a dedicated observation on the magnetar SGR J1935+2154. Thanks to the wide energy band (1-250 keV) and high sensitivity of Insight-HXMT, we obtained 75 bursts from SGR J1935+2154 during a month-long activity episode after the emission of FRB 200428. Here, we report the detailed time-integrated spectral analysis of these bursts and the statistical distribution of the spectral parameters. We find that for 15%(11/75) of SGR J1935+2154 bursts, the CPL model is preferred, and most of them occurred in the latter part of this active epoch. In the cumulative fluence distribution, we find that the fluence of bursts in our sample is about an order of magnitude weaker than that of Fermi/GBM, but follows the same power law distribution. Finally, we find a burst with similar peak energy to the time-integrated spectrum of the X-ray burst associated with FRB 200428 (FRB 200428-Associated Burst), but the low energy index is harder.

astro-ph.HE↗

Quasi-periodic oscillations of the X-ray burst from the magnetar SGR J1935+2154 and associated with the fast radio burst FRB 200428

The origin(s) and mechanism(s) of fast radio bursts (FRBs), which are short radio pulses from cosmological distances, have remained a major puzzle since their discovery. We report a strong Quasi-Periodic Oscillation(QPO) of 40 Hz in the X-ray burst from the magnetar SGR J1935+2154 and associated with FRB 200428, significantly detected with the Hard X-ray Modulation Telescope (Insight-HXMT) and also hinted by the Konus-Wind data. QPOs from magnetar bursts have only been rarely detected; our 3.4 sigma (p-value is 2.9e-4) detection of the QPO reported here reveals the strongest QPO signal observed from magnetars (except in some very rare giant flares), making this X-ray burst unique among magnetar bursts. The two X-ray spikes coinciding with the two FRB pulses are also among the peaks of the QPO. Our results suggest that at least some FRBs are related to strong oscillation processes of neutron stars. We also show that we may overestimate the significance of the QPO signal and underestimate the errors of QPO parameters if QPO exists only in a fraction of the time series of a X-ray burst which we use to calculate the Leahy-normalized periodogram.

astro-ph.HE↗

Insight-HXMT dedicated 33-day observation of SGR J1935+2154 I. Burst Catalog

Magnetars are neutron stars with extreme magnetic field and sometimes manifest as soft gamma-ray repeaters (SGRs). SGR J1935+2154 is one of the most prolific bursters and the first confirmed source of fast radio burst (i.e. FRB 200428). Encouraged by the discovery of the first X-ray counterpart of FRB, Insight-Hard X-ray Modulation Telescope (Insight-HXMT) implemented a dedicated 33-day long ToO observation of SGR J1935+2154 since April 28, 2020. With the HE, ME, and LE telescopes, Insight-HXMT provides a thorough monitoring of burst activity evolution of SGR J1935+2154, in a very broad energy range (1-250 keV) with high temporal resolution and high sensitivity, resulting in a unique valuable data set for detailed studies of SGR J1935+2154. In this work, we conduct a comprehensive analysis of this observation including detailed burst search, identification and temporal analyses. After carefully removing false triggers, we find a total of 75 bursts from SGR J1935+2154, out of which 70 are single-pulsed. The maximum burst rate is about 56 bursts/day. Both the burst duration and the waiting time between two successive bursts follow log-normal distributions, consistent with previous studies. We also find that bursts with longer duration (some are multi-pulsed) tend to occur during the period with relatively high burst rate. There is no correlation between the waiting time and the fluence or duration of either the former or latter burst. It also seems that there is no correlation between burst duration and hardness ratio, in contrast to some previous reports. In addition, we do not find any X-ray burst associated with any reported radio bursts except for FRB 200428.

astro-ph.HE↗

X-ray fine structure of a limb solar flare revealed by Insight-HXMT, RHESSI and Fermi

We conduct a detailed analysis of an M1.3 limb flare occurring on 2017 July 3, which have the X-ray observations recorded by multiple hard X-ray telescopes, including Hard X-ray Modulation Telescope (Insight-HXMT), Ramaty High Energy Solar Spectroscopic Imager (RHESSI), and The Fermi Gamma-ray Space Telescope (FERMI). Joint analysis has also used the EUV imaging data from the Atmospheric Imaging Assembly (AIA) aboard the Solar Dynamic Observatory. The hard X-ray spectral and imaging evolution suggest a lower corona source, and the non-thermal broken power law distribution has a rather low break energy $\sim$ 15 keV. The EUV imaging shows a rather stable plasma configuration before the hard X-ray peak phase, and accompanied by a filament eruption during the hard X-ray flare peak phase. Hard X-ray image reconstruction from RHESSI data only shows one foot point source. We also determined the DEM for the peak phase by SDO/AIA data. The integrated EM beyond 10 MK at foot point onset after the peak phase, while the $>$ 10 MK source around reconnection site began to fade. The evolution of EM and hard X-ray source supports lower corona plasma heating after non-thermal energy dissipation. The combination of hard X-ray spectra and images during the limb flare provides the understanding on the interchange of non-thermal and thermal energies, and relation between lower corona heating and the upper corona instability.

astro-ph.HE↗

In-orbit timing calibration of the Insight-Hard X-ray Modulation Telescope

We describe the timing system and the timing calibration results of the three payloads on-board the Insight-Hard X-ray Modulation Telescope (Insight-HXMT). These three payloads are the High Energy X-ray telescope (HE, 20-250 keV), the Medium Energy X-ray telescope (ME, 5-30 keV) and the low Energy X-ray telescope (LE, 1-10 keV). We present a method to correct the temperature-dependent period response and the long-term variation of the on-board crystal oscillator, especially for ME that does not carry a temperature-compensated crystal oscillator. The time of arrivals (ToAs) of the Crab pulsar are measured to evaluate the accuracy of the timing system. As the ephemeris of the Crab pulsar given by Jodrell Bank observatory has systematic errors around 40 μs (Rots et al. 2014), we use the quasi-simultaneous observations of the X-ray Timing Instrument (XTI) on-board the Neutron star Interior Composition Explorer (NICER) to produce the Crab ephemerides and to verify the timing system of Insight-HXMT. The energy-dependent ToAs' offsets relative to the NICER measurements including physical and instrumental origins are about 24.7μs, 10.1μs and 864.7μs, and the systematic errors of the timing system are determined as 12.1μs, 8.6μs, and 15.8μs, for HE, ME and LE respectively.

astro-ph.HE↗

Detection of flare multi-periodic pulsations in mid-ultraviolet Balmer continuum, Ly-alpha, hard X-ray, and radio emissions simultaneously

Quasi-periodic pulsations (QPPs), which usually appear as temporal pulsations of the total flux, are frequently detected in the light curves of solar/stellar flares. In this study, we present the investigation of non-stationary QPPs with multiple periods during the impulsive phase of a powerful flare on 2017 September 06, which were simultane- ously measured by the Large-Yield RAdiometer (LYRA) and the Hard X-ray Modula- tion Telescope (Insight-HXMT), as well as the ground-based BLENSW. The multiple periods, detected by applying a wavelet transform and Lomb-Scargle periodogram to the detrended light curves, are found to be about 20-55 s in the Ly-alpha and mid-ultraviolet Balmer continuum emissions during the flare impulsive phase. Similar QPPs with multi- ple periods are also found in the hard X-ray emission and low-frequency radio emission. Our observations suggest that the flare QPPs could be related to nonthermal electrons accelerated by the repeated energy release process, i.e., triggering of repetitive magnetic reconnection, while the multiple periods might be modulated by the sausage oscillation of hot plasma loops. For the multi-periodic pulsations, other generation mechanisms could not be completely ruled out.

astro-ph.SR↗

Insight-HXMT observations of jet-like corona in a black hole X-ray binary MAXI J1820+070

A black hole X-ray binary produces hard X-ray radiation from its corona and disk when the accreting matter heats up. During an outburst, the disk and corona co-evolves with each other. However, such an evolution is still unclear in both its geometry and dynamics. Here we report the unusual decrease of the reflection fraction in MAXI J1820+070, which is the ratio of the coronal intensity illuminating the disk to the coronal intensity reaching the observer, as the corona is observed to contrast during the decay phase. We postulate a jet-like corona model, in which the corona can be understood as a standing shock where the material flowing through. In this dynamical scenario, the decrease of the reflection fraction is a signature of the corona's bulk velocity. Our findings suggest that as the corona is observed to get closer to the black hole, the coronal material might be outflowing faster.

astro-ph.HE↗

The design of the Ali CMB Polarization Telescope receiver

Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polarization-sensitive Transition-Edge Sensors (TESes). Each module includes 1,704 optically active TESes fabricated on a 150mm diameter silicon wafer. Each TES array is read out with a microwave multiplexing readout system capable of a multiplexing factor up to 2,048. Such a large multiplexing factor has allowed the practical deployment of tens of thousands of detectors, enabling the design of a receiver that can operate up to 19 TES arrays for a total of 32,376 TESes. AliCPT-1 leverages the technological advancements in the detector design from multiple generations of previously successful feedhorn-coupled polarimeters, and in the instrument design from BICEP-3, but applied on a larger scale. The cryostat receiver is currently under integration and testing. During the first deployment year, the focal plane will be populated with up to 4 TES arrays. Further TES arrays will be deployed in the following years, fully populating the focal plane with 19 arrays on the fourth deployment year. Here we present the AliCPT-1 receiver design, and how the design has been optimized to meet the experimental requirements.

astro-ph.IM↗

Design and Calibration of the High Energy Particle Monitor onboard the Insight-HXMT

Three high energy particle monitors (HPMs) employed onboard the Hard X-ray Modulation Telescope Insight-HXMT) can detect the charged particles from South Atlantic Anomaly (SAA) and hence provide the alert trigger for switch-on/off of the main detectors. Here a typical design of HPM with high stability and reliability is adopted by taking a plastic scintillator coupled with a small photomultiplier tube (PMT). The window threshold of HPM is designed as 1 MeV and 20 MeV for the incident electron and proton, respectively. Before the launch of Insight-HXMT, we performed in details the ground calibration of HPM. The measured energy response and its dependence on temperature are taken as essential input of Geant4 simulation for estimating the HPM count rate given with an incident particle energy spectrum. This serves as a guidance for choosing a reasonable working range of the PMT high voltage once the real SAA count rate is measured by HPM in orbit. So far the three HPMs have been working in orbit for more than two years. Apart from providing reliable alert trigger, the HPMs data are used as well to map the SAA region.

physics.ins-det↗

In-flight calibration of the Insight-Hard X-ray Modulation Telescope

We present the calibration of the Insight-Hard X-ray Modulation Telescope (Insight-HXMT) X-ray satellite, which can be used to perform timing and spectral studies of bright X-ray sources. Insight-HXMT carries three main payloads onboard: the High Energy X-ray telescope (HE), the Medium Energy X-ray telescope (ME) and the Low Energy X-ray telescope (LE). In orbit, the radioactive sources, activated lines, the fluorescence lines and celestial sources are used to calibrate the energy scale and energy resolution of the payloads. The Crab nebular is adopted as the primary effective area calibrator and empirical functions are constructed to modify the simulated effective areas of the three payloads respectively. The systematic errors of HE, compared to the model of the Crab nebular, are less than 2% in 28--120 keV and 2%--10% above 120 keV. The systematic errors of ME are less than 1.5% in 10--35 keV. The systematic errors of LE are less than 1% in 1--7 keV except the Si K--edge (1.839 keV, up to 1.5%) and less than 2% in 7--10 keV.

astro-ph.IM↗

The Medium Energy (ME) X-ray telescope onboard the Insight-HXMT astronomy satellite

The Medium Energy X-ray telescope (ME) is one of the three main telescopes on board the Insight Hard X-ray Modulation Telescope (Insight-HXMT) astronomy satellite. ME contains 1728 pixels of Si-PIN detectors sensitive in 5-30 keV with a total geometrical area of 952 cm2. Application Specific Integrated Circuit (ASIC) chips, VA32TA6, is used to achieve low power consumption and low readout noise. The collimators define three kinds of field of views (FOVs) for the telescope, 1°{\times}4°, 4°{\times}4°, and blocked ones. Combination of such FOVs can be used to estimate the in-orbit X-ray and particle background components. The energy resolution of ME is ~3 keV at 17.8 keV (FWHM) and the time resolution is 255 μs. In this paper, we introduce the design and performance of ME.

astro-ph.IM↗

Accretion in Strong Field Gravity with eXTP

In this paper we describe the potential of the enhanced X-ray Timing and Polarimetry (eXTP) mission for studies related to accretion flows in the strong field gravity regime around both stellar-mass and supermassive black-holes. eXTP has the unique capability of using advanced 'spectral-timing-polarimetry' techniques to analyze the rapid variations with three orthogonal diagnostics of the flow and its geometry, yielding unprecedented insight into the inner accreting regions, the effects of strong field gravity on the material within them and the powerful outflows which are driven by the accretion process.

astro-ph.HE↗

A Transmissive X-ray Polarimeter Design For Hard X-ray Focusing Telescopes

The X-ray Timing and Polarization (XTP) is a mission concept for a future space borne X-ray observatory and is currently selected for early phase study. We present a new design of X-ray polarimeter based on the time projection gas chamber. The polarimeter, placed above the focal plane, has an additional rear window that allows hard X-rays to penetrate (a transmission of nearly 80% at 6 keV) through it and reach the detector on the focal plane. Such a design is to compensate the low detection efficiency of gas detectors, at a low cost of sensitivity, and can maximize the science return of multilayer hard X-ray telescopes without the risk of moving focal plane instruments. The sensitivity in terms of minimum detectable polarization, based on current instrument configuration, is expected to be 3% for a 1mCrab source given an observing time of 10^5 s. We present preliminary test results, including photoelectron tracks and modulation curves, using a test chamber and polarized X-ray sources in the lab.

astro-ph.IM↗