SearcharxivSearch

arXiv subjects

Fernando Chierchie

Publications and source records attributed to Fernando Chierchie.

28 records · Page 2Linked to original sources

Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab

Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the MeV mass range.

hep-ex

Fast Single-Quantum Measurement with a Multi-Amplifier Sensing Charge-Coupled Device

A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier; measurements with multiple amplifiers can then be combined to further reduce the readout noise. The readout speed of this detector scales roughly linearly with the number of amplifiers without requiring segmentation of the active area. The performance of this detector is demonstrated, emphasizing the ability to resolve individual quanta and the ability to combine measurements across amplifiers to reduce readout noise. The unprecedented low noise and fast readout of the MAS-CCD make it a unique technology for astronomical observations, quantum imaging, and low-energy interacting particles.

astro-ph.IM

The Oscura Experiment

The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.

astro-ph.IM

SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.

physics.ins-det

Smart readout of nondestructive image sensors with single-photon sensitivity

Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible-light and other applications that require faster readout times. The method optimizes the readout noise and time by changing the number of times pixels are read out either statically, by defining an arbitrary number of regions of interest (ROI) in the array, or dynamically, depending on the charge or energy of interest (EOI) in the pixel. This technique is tested in a Skipper CCD showing that it is possible to obtain deep sub-electron noise, and therefore, high resolution of quantized charge, while dynamically changing the readout noise of the sensor. These faster, low noise readout techniques show that the skipper CCD is a competitive technology even where other technologies such as Electron Multiplier Charge Coupled Devices (EMCCD), silicon photo multipliers, etc. are currently used. This technique could allow skipper CCDs to benefit new astronomical instruments, quantum imaging, exoplanet search and study, and quantum metrology.

astro-ph.IM

The Skipper CCD for low-energy threshold particle experiments above ground

We present experimental results using a single-electron resolution Skipper-CCD running above ground level to demonstrate the potential of this technology for its use in reactor neutrino observations and other low-energy particle interaction experiments. Operating conditions and event-selection criteria are provided to decouple most of the background rate at low energies. Our final results for events with energies as low as $5$ ionized electron-hole pairs show that the exponentially increasing rate of events seen in other technologies is not present in our data. This demonstrates that the Skipper CCD proves to be among the best options to measure low energy and weakly interacting particles at ground level.

hep-ex

Analog pile-up circuit technique using a single capacitor for the readout of Skipper-CCD detectors

With Skipper-CCD detectors it is possible to take multiple samples of the charge packet collected on each pixel. After averaging the samples, the noise can be extremely reduced allowing the exact counting of electrons per pixel. In this work we present an analog circuit that, with a minimum number of components, applies a double slope integration (DSI), and at the same time, it averages the multiple samples producing at its output the pixel value with sub-electron noise. For this prupose, we introduce the technique of using the DSI integrator capacitor to add the skipper samples. An experimental verification using discrete components is presented, together with an analysis of its noise sources and limitations. After averaging 400 samples it was possible reach a readout noise of 0.2\,$e^-_{RMS}/pix$, comparable to other available readout systems. Due to its simplicity and significant reduction of the sampling requirements, this circuit technique is of particular interest in particle experiments and cameras with a high density of Skipper-CCDs.

physics.ins-det

Smart-readout of the Skipper-CCD: Achieving Sub-electron Noise Levels in Regions of Interest

The skipper CCD is a special type of charge coupled device in which the readout noise can be reduced to sub-electron levels by averaging independent measurements of the same charge. Thus the charge in the pixels can be determined by counting the exact number of electrons. The total readout time is proportional to the number of measurements of the charge in each pixel. For some applications this time may be too long; however, researchers usually are interested only on certain region within the matrix of pixels. In this paper we present the development of a smart skipper readout technique that allows the user to specify regions of interest of the CCD matrix where an arbitrary (high) number of measurements of the same charge can taken to obtain the desired noise level, and far less measurements are performed in those regions that are less interesting to the researcher, therefore reducing the total readout time.

physics.ins-det

SENSEI: Direct-Detection Results on sub-GeV Dark Matter from a New Skipper-CCD

We present the first direct-detection search for eV-to-GeV dark matter using a new ~2-gram high-resistivity Skipper-CCD from a dedicated fabrication batch that was optimized for dark-matter searches. Using 24 days of data acquired in the MINOS cavern at the Fermi National Accelerator Laboratory, we measure the lowest rates in silicon detectors of events containing one, two, three, or four electrons, and achieve world-leading sensitivity for a large range of sub-GeV dark matter masses. Data taken with different thicknesses of the detector shield suggest a correlation between the rate of high-energy tracks and the rate of single-electron events previously classified as "dark current." We detail key characteristics of the new Skipper-CCDs, which augur well for the planned construction of the ~100-gram SENSEI experiment at SNOLAB.

astro-ph.CO

Low Threshold Acquisition controller for Skipper CCDs

The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the operation of the detector in high sensitivity scientific applications. The article describes the main components and functionality of the Low Threshold Acquisition (LTA) together with experimental results when connected to a Skipper-CCD sensor. Measurements show unprecedented deep sub-electron noise of 0.039 e$^-_{rms}$/pix for 5000 pixel measurements.

astro-ph.IM