SearcharxivSearch

arXiv subjects

Filippo Levi

Publications and source records attributed to Filippo Levi.

At least 19 recordsLinked to original sources

Spectral evolution of two-photon emission in microresonators

High-Q silicon nitride microresonators are versatile sources for generating photon pairs via four-wave mixing. We investigate the spectral coherence of this process, tracking the transition from the spontaneous quantum regime to the onset of optical parametric oscillation. By combining time-correlation measurements with phase-sensitive measurements, we continuously monitor the emission linewidth as it evolves from a cavity-lifetime-limited linewidth toward the pump-linewidth scale. This characterization is essential for optimizing integrated sources for scalable quantum networks.

quant-ph

International Optical Clock Comparison Using the European Optical Fiber Network

Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the $10^{-18}$ level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from $7.7\times10^{-18}$ to $6.1\times10^{-17}$. Among the results, the $^{171}$Yb$^+$(E3) clocks at NPL and PTB demonstrated agreement within an uncertainty of $7.7\times10^{-18}$, marking the first international verification of two independently developed optical clocks below one part in $10^{17}$. The operation of the $^{199}$Hg clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with $^{171}$Yb$^+$(E3), $^{171}$Yb, and $^{87}$Sr optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.

physics.atom-ph

A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison

An intercontinental metrological clock comparison between Italy and the Republic of Korea was performed by means of geodetic K-band VLBI observations. The comparison involved the hydrogen masers (H-masers) used at Medicina and Sejong radio telescopes. The same clocks were simultaneously compared by a satellite link and by high-precision optical clocks maintained at the National Metrology Institutes, KRISS in Korea and INRIM in Italy, and delivered to VLBI antennas via optical fiber. The H-masers frequency difference was estimated by extrapolating the clock rate from VLBI data using two geodetic VLBI software. This was subsequently compared with clock differences derived by satellite link and by local optical clocks. Results obtained with different approaches were in agreement at the level of $10^{-15}$ s/s. This pilot study demonstrates that standard high-frequency (K-band) geodetic VLBI campaigns could be a viable approach to conduct intercontinental clock comparisons, now only possible via satellite links. This uncertainty can be reduced thanks to the planned installation of new-generation, broadband, high-frequency receivers on the involved telescopes. K/Q/W-band geodetic observations will allow an improvement of the accuracy of the resulting group delays through broad bandwidth synthesis from 20 to 100 GHz. Furthermore, the Frequency Phase Transfer (FPT) method will also be explored together with the use of PCAL systems installed at the radio telescopes to improve phase stability and thus allow a better estimation of the station clock parameters.

astro-ph.IM

Vocabulary, Physical Quantities and Units for the Measurement of Amplitude Noise and Phase Noise

The widespread use of non-SI quantities and units, together with improper and misleading terminology, generates confusion in the domain of phase and amplitude noise. We discuss such physical quantities, units and terms with the purpose of stimulating a discussion between labs, and to agree for the full adoption of the International System of Units (SI) and clear, unambiguous terminology.

physics.ins-det

Atomic thermometry in optical lattice clocks

Accurate measurement of atomic temperature is fundamental for a wide range of applications, from quantum sensing to precision metrology. In optical lattice clocks, precise characterization of atomic temperature is required to minimize systematic uncertainties at the $10^{-18}$ level. In this work, we investigate atomic temperature measurements in the ytterbium optical lattice clock developed at INRIM, IT-Yb1, employing sideband and Doppler spectroscopy across a wide range of trapping conditions. By implementing clock-line-mediated Sisyphus cooling [Phys. Rev. Lett. 133, 053401 (2024)], we reduce the atomic temperature and enable operation at shallower lattice depths down to $D = 50E_{R}$. We compare temperature estimates obtained from the harmonic oscillator model with those derived using a Born-Oppenheimer-based approach [Phys. Rev. A 101, 053416 (2020)], which is expected to provide a more accurate description of atomic motion in both longitudinal and radial directions, especially for hotter atoms whose motion deviates from the harmonic regime. Discrepancies up to a factor of two in extracted temperatures are observed depending on the chosen model. We assess the impact of these modeling differences on the evaluation of lattice shifts and find relative frequency deviations up to $8\times10^{-17}$. Even though extended Sisyphus cooling reduces these inconsistencies to the $1\times10^{-18}$ level, residual biases may still limit the accuracy of optical lattice clocks.

physics.atom-ph

Coordinated international comparisons between optical clocks connected via fiber and satellite links

Optical clocks provide ultra-precise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time, while others had significantly lower uncertainties than previously achieved, supporting the advance towards a redefinition of the second and the use of optical standards for international time scales.

physics.atom-ph

QKD protected fiber-based infrastructure for time dissemination

In this study, we demonstrate the possibility to protect, with Quantum Key Distribution (QKD), a critical infrastructure as the fiber-based one used for time and frequency (TF) dissemination service. The proposed technique allows to disseminate secure and precise TF signals between two fiber-opticconnected locations, on a critical infrastructure, using both QKD and White Rabbit technique. This secure exchange allows the secret sharing of time information between two parties for the synchronization of distant clocks with the highest stability and traceable to the Italian time scale. When encrypted, time signals would reveal to a third party no useful information about the synchronization status, providing a time stability two orders of magnitude worsened.

quant-ph

Laser Frequency Stabilization Using Light Shift in Compact Atomic Clocks

This paper describes the Light-Shift Laser-Lock (LSLL) technique, a novel method intended for compact atomic clocks that greatly simplifies the laser setup by stabilizing the pumping-laser frequency to the atoms involved in the clock, without the need of an external reference. By alternating two clock sequences with different light shifts, the method estimates and cancels out a controlled amount of induced light shift, acting on the laser frequency. The LSLL technique is compatible with state-of-the-art 3-level clocks and was demonstrated with FPGA-based electronics on a pulsed-optically-pumped (POP) vapor-cell clock developed at INRIM. The results have shown that the LSLL technique operates robustly, having a capture range of gigahertz without significantly compromising clock stability. In our tests, the clock exhibited a white frequency noise of $3.2 \times 10^{-13}$ $\tau^{-1/2}$ for averaging time up to 4000 s, reaching a floor below $1 \times 10^{-14}$ up to 100 000 s. These performance levels meet the requirements of future Global Navigation Satellite Systems (GNSS) on-board clocks, and offer the added benefits of a reduced clock footprint, as well as increased reliability and robustness.

physics.atom-ph

Phase Noise in Real-World Twin-Field Quantum Key Distribution

The impact of noise sources in real-world implementations of Twin-Field Quantum Key Distribution (TF-QKD) protocols is investigated, focusing on phase noise from photon sources and connecting fibers. This work emphasizes the role of laser quality, network topology, fiber length, arm balance, and detector performance in determining key rates. Remarkably, it reveals that the leading TF-QKD protocols are similarly affected by phase noise despite different mechanisms. This study demonstrates duty cycle improvements of over a factor of two through narrow-linewidth lasers and phase-control techniques, highlighting the potential synergy with high-precision time/frequency distribution services. Ultrastable lasers, evolving toward integration and miniaturization, offer promise for agile TF-QKD implementations on existing networks. Properly addressing phase noise and practical constraints allows for consistent key rate predictions, protocol selection, and layout design, crucial for establishing secure long-haul links for the Quantum Communication Infrastructures under development in several countries.

quant-ph

A pulsed optically pumped Rb clock with a frequency stability below 10-15

We present the frequency stability performances of a vapor cell Rb clock based on the pulsed optically pumping (POP) technique. The clock has been developed in the frame of a collaboration between INRIM and Leonardo SpA, aiming to realize a space-qualified POP frequency standard. The results here reported were obtained with an engineered physics package, specifically designed for space applications, joint to laboratory-grade optics and electronics. The measured frequency stability expressed in terms of Allan deviation is $1.2 \times 10^{-13}$ at 1 s and achieves the value of $6 \times 10^{-16}$ for integration times of 40000 s (drift removed). This is, to our knowledge, a record result for a vapor-cell frequency standard. In the paper, we show that in order to get this result, a careful stabilization of microwave and laser pulses is required.

physics.atom-ph

Seismic monitoring using the telecom fiber network

Laser interferometry enables to remotely measure microscopical length changes of deployed telecommunication cables originating from earthquakes. Long range and compatibility with data traffic make it unique to the exploration of remote regions, as well as highly-populated areas where optical networks are pervasive, and its large-scale implementation is attractive for both Earth scientists and telecom operators. However, validation and modeling of its response and sensitivity are still at an early stage and suffer from lack of statistically-significant event catalogs and limited availability of co-located seismometers. We implemented laser interferometry on a land-based telecommunication cable and analyzed 1.5 years of continuous acquisition, with successful detections of events in a broad range of magnitudes, including very weak ones. By comparing fiber and seismometer recordings we determined relations between a cable's detection probability and the magnitude and distance of events, and showed that spectral analysis of recorded data allows considerations on the earthquake dynamics. Our results reveal that quantitative analysis is possible for this sensing technique and support the interpretation of data from the growing amount of interferometric deployments. We anticipate the high integration and scalability of laser interferometry into existing telecommunication grids to be useful for the daily seismicity monitoring, in perspective exploitable for civilian protection use.

physics.geo-ph

Absolute frequency measurement of a Yb optical clock at the limit of the Cs fountain

We present the new absolute frequency measurement of ytterbium (171Yb) obtained at INRiM with the optical lattice clock IT-Yb1 against the cryogenic caesium (133Cs) fountain IT-CsF2, evaluated through a measurement campaign that lasted 14 months. Measurements are performed by either using a hydrogen maser as a transfer oscillator or by synthesizing a low-noise microwave for Cs interrogation using an optical frequency comb. The frequency of the 171Yb unperturbed clock transition 1S0 - 3P0 results to be 518 295 836 590 863.44(14) Hz, with a total fractional uncertainty of 2.7e-16 that is limited by the uncertainty of IT-CsF2. Our measurement is in agreement with the Yb frequency recommended by the Consultative Committee for Time and Frequency (CCTF). This result confirms the reliability of Yb as a secondary representation of the second and is relevant to the process of redefining the second in the International System of Units (SI) on an optical transition

physics.atom-ph

Improving the resolution of comb-based frequency measurements using a track and hold amplifier

The advent of optical frequency standards with ultimate uncertainties in the low 1x10$^{-18}$ requires femtosecond frequency combs to support a similar level of resolution in the spectral transfer and the computation of optical frequency ratios. The related experimental challenges grow together with the number of optical frequencies to be measured simultaneously, as in many cases the comb's optical power does not allow reliable beatnote counting or tracking in all the spectral regions of interest. Here we describe the use of a track-and-hold amplifier to implement the gated detection, a previously proposed technique for improving the signal-to-noise ratio of the beatnote between a low-power tooth of the frequency comb and a continuous wave laser. We demonstrate a 12dB improvement in the signal-to-noise ratio of beatnotes involving a broadband-spanning optical comb as compared to traditional detection schemes. Our approach enables reliable and cycle-slip-free spectral purity transfer and reduces the system sensitivity to power drops in the comb spectrum. Being based on a single chip, it is robust, versatile and easily embedded in more complex experimental schemes. Keywords: frequency comb, spectral purity transfer, gated detection, track and hold amplifier.

physics.ins-det

Frequency noise characterization of diode lasers for vapor cell clocks applications

The knowledge of the frequency noise spectrum of a diode laser is of interest in several high resolution experiments. Specifically, in laser-pumped vapor cell clocks, it is well established that the laser frequency noise plays a role in affecting the clock performances. It is then important to characterize the frequency noise of a diode laser, especially since such measurements are rarely found in the literature and hardly ever provided by vendors. In this paper, we describe a technique based on a frequency-to-voltage converter that transforms the laser frequency fluctuations into voltage fluctuations. In this way, it is possible to characterize the laser frequency noise power spectral density in a wide range of Fourier frequencies, as required in cell clock applications.

physics.atom-ph

Optically loaded Strontium lattice clock with a single multi-wavelength reference cavity

We report on the realization of a new compact strontium optical clock using a 2-D magneto-optical-trap (2D-MOT) as cold atomic source and a multi-wavelength cavity as the frequency stabilization system. All needed optical frequencies are stabilized to a zero-thermal expansion high-finesse optical resonator and can be operated without frequency adjustments for weeks. We present the complete characterization of the apparatus. Optical control of the atomic source allows us to perform low-noise clock operation without atomic signal normalization. Long- and short-term stability tests of the clock have been performed for the 88 Sr bosonic isotope by means of interleaved clock operation. Finally, we present the first preliminary accuracy budget of the system.

physics.atom-ph

Coherent phase transfer for real-world twin-field quantum key distribution

Quantum mechanics allows the distribution of intrinsically secure encryption keys by optical means. Twin-field quantum key distribution is the most promising technique for its implementation on long-distance fibers, but requires stabilizing the optical length of the communication channels between parties. In proof-of-principle experiments based on spooled fibers, this was achieved by interleaving the quantum communication with periodical adjustment frames. In this approach, longer duty cycles for the key streaming come at the cost of a looser control of channel length, and a successful key-transfer using this technique in a real world remains a significant challenge. Using interferometry techniques derived from frequency metrology, we developed a solution for the simultaneous key streaming and channel length control, and demonstrate it on a 206 km field-deployed fiber with 65 dB loss. Our technique reduces the quantum-bit-error-rate contributed by channel length variations to <1%, representing an effective solution for real-world quantum communications.

quant-ph

Loaded microwave cavity for compact vapor-cell clocks

Vapor-cell devices based on microwave interrogation provide a stable frequency reference with a compact and robust setup. Further miniaturization must focus on optimizing the physics package, containing the microwave cavity and atomic reservoir. In this paper we present a compact cavity-cell assembly based on a dielectric-loaded cylindrical resonator. The structure accommodates a clock cell with $0.9 \, \mathrm{cm^3}$ inner volume and has an outer volume of only $35 \, \mathrm{cm^3}$. The proposed design aims at strongly reducing the core of the atomic clock, maintaining at the same time high-performing short-term stability ($σ_y(τ) \leq 5\times 10^{-13} \,τ^{-1/2}$ standard Allan deviation). The proposed structure is characterized in terms of magnetic field uniformity and atom-field coupling with the aid of finite-elements calculations. The thermal sensitivity is also analyzed and experimentally characterized. We present preliminary spectroscopy results by integrating the compact cavity within a rubidium clock setup based on the pulsed optically pumping technique. The obtained clock signals are compatible with the targeted performances. The loaded-cavity approach is thus a viable design option for miniaturized microwave clocks.

physics.atom-ph

A Sideband-Enhanced Cold Atomic Source For Optical Clocks

We demonstrate the enhancement and optimization of a cold strontium atomic beam from a two-dimensional magneto-optical trap (2D-MOT) transversely loaded from a collimated atomic beam by adding a sideband frequency to the cooling laser. The parameters of the cooling and sideband beams were scanned to achieve the maximum atomic beam flux and compared with Monte Carlo simulations. We obtained a 2.3 times larger, and 4 times brighter, atomic flux than a conventional, single-frequency 2D-MOT, for a given total power of 200 mW. We show that the sideband-enhanced 2D-MOT can reach the loading rate performances of space demanding Zeeman slower-based systems, while it can overcome systematic effects due to thermal beam collisions and hot black-body radiation shift, making it suitable for both transportable and accurate optical lattice clocks. Finally we numerically studied the possible extensions of the sideband-enhanced 2D-MOT to other alkaline-earth species.

physics.atom-ph