SearcharxivSearch

arXiv subjects

Flavio Gatti

Publications and source records attributed to Flavio Gatti.

16 recordsLinked to original sources

Letter Of Intent for a future $μ^+ \to \mathrm{e}^+ γ$ experiment at the High Intensity Muon Beam facility at PSI

Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $μ^+ \to \mathrm{e}^+ γ$ experiments provide the best constraints in this field for a wide range of models while, in the coming years, new experiments investigating the processes of $μ^+ \to \mathrm{e}^+ \mathrm{e}^+ \mathrm{e}^-$ and $μ\to \mathrm{e}$ conversion in the nuclear field are anticipated to reach comparable or higher sensitivities. The High-Intensity Muon Beam (HIMB) facility at PSI, which is expected to deliver muon beam intensities up to two orders of magnitude higher than the existing beam lines, offers a unique opportunity to significantly enhance the sensitivity of $μ^+ \to \mathrm{e}^+ γ$ searches. The discovery potential could be substantially boosted and a sensitivity comparable to that of all the other projects could be reestablished, which is essential for discriminating among competing new-physics scenarios should an observation occur in any of the channels. In this document, we express our interest in developing a $μ^+ \to \mathrm{e}^+ γ$ experimental program at HIMB, with the goal of improving, within the next decade, the sensitivity of the $μ^+ \to \mathrm{e}^+ γ$ search by more than one order of magnitude relative to the expected final result of the current leading experiment, MEG II. This effort would ensure that PSI retains its leadership in this field.

hep-ex

Impact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment

We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $^{163}$Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $^{163}$Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector's energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $^{163}$Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $^{163}$Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $^{163}$Ho to be $(2.9 \pm 0.4 \mathrm{(stat)} \pm 0.7 \mathrm{(sys)})$ J/K/mol at $(94 \pm 1)$\,mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $^{163}$Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $^{163}$Ho activities up to approximately 5 Bq without significant performance degradation. For higher activities, reducing the TES transition temperature is necessary to maintain energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling implanted radionuclides while maintaining high-resolution performance.

physics.ins-det

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4' field of view (compared to 5' before). In this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

astro-ph.IM

The TES-based Cryogenic AntiCoincidence Detector of ATHENA X-IFU: Validation of the thermal end-to-end simulator towards the updated Demonstration Model (DM 1.1)

The Cryogenic AntiCoincidence Detector (CryoAC) is a key element of the X-ray Integral Field Unit (X-IFU) on board the future ATHENA X-ray observatory. It is a TES-based detector designed to reduce the particle background of the instrument, thereby increasing its sensitivity. The detector design is driven by an end-to-end simulator which includes the electro-thermal modelling of the detector and the dynamics of its readout chain. Here, we present the measurements carried out on the last CryoAC single pixel prototype, namely DM127, in order to evaluate the critical thermal parameters of the detector and consequently to tune and validate the CryoAC end-to-end simulator.

astro-ph.IM

The end-to-end simulator of the ATHENA X-IFU Cryogenic AntiCoincidence detector (CryoAC)

The X-IFU is one of the two instruments of ATHENA, the next ESA large X-ray observatory. It is a cryogenic spectrometer based on an array of TES microcalorimeters. To reduce the particle background, the TES array works in combination with a Cryogenic AntiCoincidence detector (CryoAC). The CryoAC is a 4-pixel detector, based on ~1 cm2 silicon absorbers sensed by Ir/Au TES. It is required to have a wide energy bandwidth (from 20 keV to ~1 MeV), high efficiency (< 0.014% missed particles), low dead-time (< 1%) and good time-tagging accuracy (10 us at 1 sigma). An end-to-end simulator of the CryoAC detector has been developed both for design and performance assessment, consisting of several modules. First, the in-flight flux of background particles is evaluated by Geant4 simulations. Then, the current flow in the TES is evaluated by solving the electro-thermal equations of microcalorimeters, and the detector output signal is generated by simulating the SQUID FLL dynamics. Finally, the output is analyzed by a high-efficiency trigger algorithm, producing the simulated CryoAC telemetry. Here, we present in detail this end-to-end simulator, and how we are using it to define the new CryoAC baseline configuration in the new Athena context.

astro-ph.IM

The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).

astro-ph.IM

The Search for $μ^+\to e^+ γ$ with 10$^{-14}$ Sensitivity: the Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$) $<4.2 \times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6\times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7\times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

hep-ex

The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector

The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first CryoAC DM sample (namely the AC-S10 prototype), showing that it is fully compliant with its requirements.

astro-ph.IM

The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of the test setup towards the Demonstration Model

The ATHENA X-IFU development program foresees to build and characterize an instrument Demonstration Model (DM), in order to probe the system critical technologies before the mission adoption. In this respect, we are now developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC), which will be delivered to the Focal Plane Assembly (FPA) development team for the integration with the TES array. Before the delivery, we will characterize and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the main results of the activities performed to improve our cryogenic test setup, making it suitable for the DM integration. These activities mainly consist in the development of a mechanichal setup and a cryogenic magnetic shielding system, whose effectiveness has been assessed by FEM simulations and a measurement at warm. The preliminary performance test has been performed by means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.

astro-ph.IM

The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the role of the athermal phonons collectors in the AC-S8 prototype

The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters. To reduce the particle-induced background, the spectrometer works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed less than 1 mm below the TES array. The last CryoAC single-pixel prototypes, namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers sensed by 65 parallel-connected iridium TES. This design has been adopted to improve the response generated by the athermal phonons, which will be used as fast anticoincidence flag. The latter sample is featured also with a network of Aluminum fingers directly connected to the TES, designed to further improve the athermals collection efficiency. In this paper we will report the main results obtained with AC-S8, showing that the additional fingers network is able to increase the energy collected from the athermal part of the pulses (from the 6% of AC-S7 up to the 26 % with AC-S8). Furthermore, the finger design is able to prevent the quasiparticle recombination in the aluminum, assuring a fast pulse rising front (L/R limited). In our road map, the AC-S8 prototype is the last step before the development of the CryoAC Demonstration Model (DM), which will be the detector able to demonstrate the critical technologies expected in the CryoAC development programme.

astro-ph.IM

The Athena X-ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of about 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.

astro-ph.IM

The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary test of AC-S9 towards the Demonstration Model

Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bath, the threshold energy at 20 keV and the reproducibility of the thermal conductance between the suspended absorber and the thermal bath. This detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and then delivered to SRON for the integration in the X-IFU Focal Plane Assemby (FPA) DM. In this paper we report the status of the CryoAC DM development, showing the main result obtained with the last developed prototype, namely AC-S9. This is a DM-like sample, which we have preliminary integrated and tested before performing the final etching process to suspend the silicon absorber. The results are promising for the DM, since despite the limitations due to the absence of the final etching (high thermal capacity, high thermal conductance, partial TES surface coverage), we have been able to operate the detector with TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold fully compatible with our requirement (20 keV).

astro-ph.IM

The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific assessment of the observational capabilities in the hard X-ray band

ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028 towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a cryogenic spectrometer based on a large array of TES microcalorimeters, able to perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6 keV). The X-IFU sensitivity is highly degraded by the particle background expected in the L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the particle background level and enable the mission science goals, the instrument incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES based detector, placed <1 mm below the main array. In this paper we report a scientific assessment of the CryoAC observational capabilities in the hard X-ray band (E>10 keV). The aim of the study has been to understand if the present detector design can be improved in order to enlarge the X-IFU scientific capability on an energy band wider than the TES array. This is beyond the CryoAC baseline, being this instrument aimed to operate as anticoincidence particle detector and not conceived to perform X-ray observations.

astro-ph.IM

The Athena X-ray Integral Field Unit (X-IFU)

The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we briefly describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution). The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with further ESA member state contributions from Belgium, Finland, Germany, Poland, Spain, Switzerland and two international partners from the United States and Japan.

astro-ph.IM

Development of High Precision Timing Counter Based on Plastic Scintillator with SiPM Readout

High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have studied counter sizes up to $120\times40\times5$ mm^3 with series connection of multiple SiPMs to increase the sensitive area and thus achieve better time resolution. A readout scheme with analog shaping and digital waveform analysis is optimized to achieve the highest time resolution. The timing performance is measured using electrons from a Sr-90 radioactive source, comparing different scintillators, counter dimensions, and types of near-ultraviolet sensitive SiPMs. As a result, a resolution of $σ=42 \pm 2$ ps at 1 MeV energy deposition is obtained for counter size $60\times 30 \times 5$ mm^3 with three SiPMs ($3\times3$ mm^2 each) at each end of the scintillator. The time resolution improves with the number of photons detected by the SiPMs. The SiPMs from Hamamatsu Photonics give the best time resolution because of their high photon detection efficiency in the near-ultraviolet region. Further improvement is possible by increasing the number of SiPMs attached to the scintillator.

physics.ins-det