arXiv · 1912.06390
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
Abstract
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first CryoAC DM sample (namely the AC-S10 prototype), showing that it is fully compliant with its requirements.
Explore related subjects
Keep this discovery
Matteo D'Andrea, Claudio Macculi, Guido Torrioli, Andrea Argan, Daniele Brienza, Simone Lotti, Gabriele Minervini, Luigi Piro, Michele Biasotti, Lorenzo Ferrari Barusso, Flavio Gatti, Manuela Rigano, Angela Volpe, Elia Stefano Battistelli. 2019-12-13. The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector. https://doi.org/10.1007/s10909-019-02300-9
Cite the original work for its findings. Save a collection to share your selection of sources.