Searcharxiv⌕ Search

arXiv subjects

Frédéric Druillole

Publications and source records attributed to Frédéric Druillole.

At least 19 recordsLinked to original sources

Prospects for geoneutrino detection with JUNO

Geoneutrinos, which are antineutrinos emitted during the decay of long-lived radioactive elements inside Earth, serve as a unique tool for studying the composition and heat budget of our planet. The Jiangmen Underground Neutrino Observatory (JUNO) experiment in China, which has recently completed construction, is expected to collect a sample comparable in size to the entire existing world geoneutrino dataset in less than a year. This paper presents an updated estimation of sensitivity to geoneutrinos of JUNO using the best knowledge available to date about the experimental site, the surrounding nuclear reactors, the detector response uncertainties, and the constraints expected from the TAO satellite detector. To facilitate comparison with present and future geological models, our results cover a wide range of predicted signal strengths. Despite the significant background from reactor antineutrinos, the experiment will measure the total geoneutrino flux with a precision comparable to that of existing experiments within its first few years, ultimately achieving a world-leading precision of about 8% over ten years. The large statistics of JUNO will also allow separation of the Uranium-238 and Thorium-232 contributions with unprecedented precision, providing crucial constraints on models of formation and composition of Earth. Observation of the mantle signal above the lithospheric flux will be possible but challenging. For models with the highest predicted mantle concentrations of heat-producing elements, a 3-sigma detection over six years requires knowledge of the lithospheric flux to within 15%. Together with complementary measurements from other locations, the geoneutrino results of JUNO will offer cutting-edge, high-precision insights into the interior of Earth, of fundamental importance to both the geoscience and neutrino physics communities.

hep-ex↗

Final assessment of radioactive impurities in the JUNO detector

The Jiangmen Underground Neutrino Observatory (JUNO) collaboration has completed the construction of the 20,000-ton liquid scintillator detector and the associated muon veto detector system. To meet the physics objectives, the materials used in the detector must exhibit low radioactive contamination. The single-event rate in the fiducial volume (R $<$ 17.2 m) of the scintillator is required to be approximately 7 Hz for energies above 0.7 MeV, resulting in an accidental coincidence background of about 1 event per day for reactor neutrino physics analyses. Since the beginning of the construction phase, we have screened the natural radioactivity content of thousands of materials, to select those that meet the design background budget. The radioactive impurity concentrations of the materials ultimately used in the JUNO detector are summarized in this paper. The construction of the entire detector and the subsequent filling of the liquid scintillator were completed in August 2025. From the initial data, the total count rate of natural radioactivity within the detector's fiducial volume has met the requirements and is sufficient to support the reactor antineutrino analysis.

physics.ins-det↗

A Low-energy Threshold and Multi-messenger Trigger System for the JUNO Experiment

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20-kiloton liquid scintillator neutrino detector, located 650 meters (1800 m.w.e.) underground in Jiangmen, Guangdong, China. JUNO is primarily designed for reactor neutrino measurements and has been taking data since 2025. With the largest mass of its kind and an excellent energy resolution, JUNO is a leading observatory for high-precision measurements of MeV neutrinos. The standard global trigger system serves as the primary trigger for JUNO. We present a newly developed multi-messenger trigger system that extends the capabilities of the global trigger by providing a lower energy threshold and an independent monitoring capability. During the 2025 operation, it achieved an effective energy threshold of approximately 110 +/- 10 keV, providing a lower threshold configuration suitable for low-energy event analysis. The system shows the potential to further reduce the threshold to well below 100 keV. Based on the multi-messenger trigger system, an astrophysical monitor has been developed to receive and process external alerts from other messengers, such as gravitational-wave observations. A Transient Neutrino Burst Monitor is integrated to detect short-time-scale neutrino burst events and enables real-time monitoring of transient astrophysical phenomena. The system is sensitive to neutrino bursts from core-collapse supernovae within a distance of about 250 kpc.

hep-ex↗

Embedded underwater front-end electronics for the 3-inch photomultipliers in the JUNO experiment

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20-kton liquid scintillator-based, low-radioactivity, multi-purpose neutrino detector located 693 meters (1800 m.w.e.) underground in the Guangdong province, China. To detect scintillation light produced in the target, the detector is equipped with 17,612 20-inch photomultipliers (PMTs), forming the Large PMT system (LPMT). In addition, 25,600 3-inch photomultipliers (the Small Photomultiplier System or SPMT) are deployed in the gaps between the LPMTs. This paper presents the design and performance of the underwater front-end electronics developed for the SPMT system. It details the individual electronics boards and their key components, the inter-board interfaces, the system-level design, and the firmware architecture that supports data acquisition and control. It also outlines mechanical and thermal integration, board validation procedures, and system performance metrics. The readout chain includes digitization of 128 PMT channels per unit, synchronized time-stamping, charge measurement, event packaging, and bandwidth management. Comprehensive validation confirms the system's readiness to meet JUNO's stringent physics goals. The underwater electronics achieve noise levels as low as 0.04 photoelectrons with minimal crosstalk (below 0.4%) and a bandwidth of 57 MB/s, ensuring reliable single photo-electron detection and operation under high-rate conditions. The SPMT system has now been fully integrated and installed in JUNO. Its commissioning and physics performance will be reported in a future publication.

physics.ins-det↗

The High Voltage Splitter board for the JUNO SPMT system

The Jiangmen Underground Neutrino Observatory (JUNO) in southern China is designed to study neutrinos from nuclear reactors and natural sources to address fundamental questions in neutrino physics. Achieving its goals requires continuous operation over a 20-year period. The small photomultiplier tube (small PMT or SPMT) system is a subsystem within the experiment composed of 25600 3-inch PMTs and their associated readout electronics. The High Voltage Splitter (HVS) is the first board on the readout chain of the SPMT system and services the PMTs by providing high voltage for biasing and by decoupling the generated physics signal from the high-voltage bias for readout, which is then fed to the front-end board. The necessity to handle high voltage, manage a large channel count, and operate stably for 20 years imposes significant constraints on the physical design of the HVS. This paper serves as a comprehensive documentation of the HVS board: its role in the SPMT readout system, the challenges in its design, performance and reliability metrics, and the methods employed for production and quality control.

physics.ins-det↗

JUNO Sensitivity on Proton Decay $p\to \barνK^+$ Searches

The Jiangmen Underground Neutrino Observatory (JUNO) is a large liquid scintillator detector designed to explore many topics in fundamental physics. In this paper, the potential on searching for proton decay in $p\to \barνK^+$ mode with JUNO is investigated.The kaon and its decay particles feature a clear three-fold coincidence signature that results in a high efficiency for identification. Moreover, the excellent energy resolution of JUNO permits to suppress the sizable background caused by other delayed signals. Based on these advantages, the detection efficiency for the proton decay via $p\to \barνK^+$ is 36.9% with a background level of 0.2 events after 10 years of data taking. The estimated sensitivity based on 200 kton-years exposure is $9.6 \times 10^{33}$ years, competitive with the current best limits on the proton lifetime in this channel.

hep-ex↗

JUNO sensitivity to the annihilation of MeV dark matter in the galactic halo

We discuss JUNO sensitivity to the annihilation of MeV dark matter in the galactic halo via detecting inverse beta decay reactions of electron anti-neutrinos resulting from the annihilation. We study possible backgrounds to the signature, including the reactor neutrinos, diffuse supernova neutrino background, charged- and neutral-current interactions of atmospheric neutrinos, backgrounds from muon-induced fast neutrons and cosmogenic isotopes. A fiducial volume cut, as well as the pulse shape discrimination and the muon veto are applied to suppress the above backgrounds. It is shown that JUNO sensitivity to the thermally averaged dark matter annihilation rate in 10 years of exposure would be significantly better than the present-day best limit set by Super-Kamiokande and would be comparable to that expected by Hyper-Kamiokande.

hep-ex↗

Prospects for Detecting the Diffuse Supernova Neutrino Background with JUNO

We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced neutral current (NC) background turns out to be the most critical background, whose uncertainty is carefully evaluated from both the spread of model predictions and an envisaged \textit{in situ} measurement. We also make a careful study on the background suppression with the pulse shape discrimination (PSD) and triple coincidence (TC) cuts. With latest DSNB signal predictions, more realistic background evaluation and PSD efficiency optimization, and additional TC cut, JUNO can reach the significance of 3$σ$ for 3 years of data taking, and achieve better than 5$σ$ after 10 years for a reference DSNB model. In the pessimistic scenario of non-observation, JUNO would strongly improve the limits and exclude a significant region of the model parameter space.

hep-ex↗

Damping signatures at JUNO, a medium-baseline reactor neutrino oscillation experiment

We study damping signatures at the Jiangmen Underground Neutrino Observatory (JUNO), a medium-baseline reactor neutrino oscillation experiment. These damping signatures are motivated by various new physics models, including quantum decoherence, $ν_3$ decay, neutrino absorption, and wave packet decoherence. The phenomenological effects of these models can be characterized by exponential damping factors at the probability level. We assess how well JUNO can constrain these damping parameters and how to disentangle these different damping signatures at JUNO. Compared to current experimental limits, JUNO can significantly improve the limits on $τ_3/m_3$ in the $ν_3$ decay model, the width of the neutrino wave packet $σ_x$, and the intrinsic relative dispersion of neutrino momentum $σ_{\rm rel}$.

hep-ex↗

Sub-percent Precision Measurement of Neutrino Oscillation Parameters with JUNO

JUNO is a multi-purpose neutrino observatory under construction in the south of China. This publication presents new sensitivity estimates for the measurement of the $Δm^2_{31}$, $Δm^2_{21}$, $\sin^2 θ_{12}$, and $\sin^2 θ_{13}$ oscillation parameters using reactor antineutrinos, which is one of the primary physics goals of the experiment. The sensitivities are obtained using the best knowledge available to date on the location and overburden of the experimental site, the nuclear reactors in the surrounding area and beyond, the detector response uncertainties, and the reactor antineutrino spectral shape constraints expected from the TAO satellite detector. It is found that the $Δm^2_{31}$, $Δm^2_{21}$, and $\sin^2 θ_{12}$ oscillation parameters will be determined to better than 0.5% precision in six years of data collection, which represents approximately an order of magnitude improvement over existing constraints.

hep-ex↗

Radioactivity control strategy for the JUNO detector

JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz in the default fiducial volume, above an energy threshold of 0.7 MeV.

physics.ins-det↗

JUNO sensitivity to low energy atmospheric neutrino spectra

Atmospheric neutrinos are one of the most relevant natural neutrino sources that can be exploited to infer properties about cosmic rays and neutrino oscillations. The Jiangmen Underground Neutrino Observatory (JUNO) experiment, a 20 kton liquid scintillator detector with excellent energy resolution is currently under construction in China. JUNO will be able to detect several atmospheric neutrinos per day given the large volume. A study on the JUNO detection and reconstruction capabilities of atmospheric $ν_e$ and $ν_μ$ fluxes is presented in this paper. In this study, a sample of atmospheric neutrino Monte Carlo events has been generated, starting from theoretical models, and then processed by the detector simulation. The excellent timing resolution of the 3'' PMT light detection system of JUNO detector and the much higher light yield for scintillation over Cherenkov allow to measure the time structure of the scintillation light with very high precision. Since $ν_e$ and $ν_μ$ interactions produce a slightly different light pattern, the different time evolution of light allows to discriminate the flavor of primary neutrinos. A probabilistic unfolding method has been used, in order to infer the primary neutrino energy spectrum from the detector experimental observables. The simulated spectrum has been reconstructed between 100 MeV and 10 GeV, showing a great potential of the detector in the atmospheric low energy region.

hep-ex↗

JUNO Physics and Detector

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20 kton LS detector at 700-m underground. An excellent energy resolution and a large fiducial volume offer exciting opportunities for addressing many important topics in neutrino and astro-particle physics. With 6 years of data, the neutrino mass ordering can be determined at 3-4 sigma and three oscillation parameters can be measured to a precision of 0.6% or better by detecting reactor antineutrinos. With 10 years of data, DSNB could be observed at 3-sigma; a lower limit of the proton lifetime of 8.34e33 years (90% C.L.) can be set by searching for p->nu_bar K^+; detection of solar neutrinos would shed new light on the solar metallicity problem and examine the vacuum-matter transition region. A core-collapse supernova at 10 kpc would lead to ~5000 IBD and ~2000 (300) all-flavor neutrino-proton (electron) scattering events. Geo-neutrinos can be detected with a rate of ~400 events/year. We also summarize the final design of the JUNO detector and the key R&D achievements. All 20-inch PMTs have been tested. The average photon detection efficiency is 28.9% for the 15,000 MCP PMTs and 28.1% for the 5,000 dynode PMTs, higher than the JUNO requirement of 27%. Together with the >20 m attenuation length of LS, we expect a yield of 1345 p.e. per MeV and an effective energy resolution of 3.02%/\sqrt{E (MeV)}$ in simulations. The underwater electronics is designed to have a loss rate <0.5% in 6 years. With degassing membranes and a micro-bubble system, the radon concentration in the 35-kton water pool could be lowered to <10 mBq/m^3. Acrylic panels of radiopurity <0.5 ppt U/Th are produced. The 20-kton LS will be purified onsite. Singles in the fiducial volume can be controlled to ~10 Hz. The JUNO experiment also features a double calorimeter system with 25,600 3-inch PMTs, a LS testing facility OSIRIS, and a near detector TAO.

hep-ex↗

CATIROC: an integrated chip for neutrino experiments using photomultiplier tubes

An ASIC named CATIROC (Charge And Time Integrated Read Out Chip) has been developed for the next-generation neutrino experiments using a large number of photomultiplier tubes (PMTs). Each CATIROC provides the time and the charge measurements for 16 configurable input channels operating in trigger-less mode. Originally designed for the light emission in water Cherenkov detectors, we show in this paper that its use can be extended to liquid-scintillator based experiments. The $\sim$26000 3-inch PMTs of the JUNO experiment, under construction in China, is a case in point. This paper describes the features of CATIROC with a special attention to the most critical points for its application to the time profile of the light emission in liquid scintillators. The achieved performances in both charge and time measurements can be inputs for future high-precision experiments making use of PMTs or other photo-sensitive detectors.

physics.ins-det↗

The Design and Sensitivity of JUNO's scintillator radiopurity pre-detector OSIRIS

The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of $^{238}$U and $^{232}$Th requires a large ($\sim$20 m$^3$) detection volume and ultralow background levels. The present paper reports on the design and major components of the OSIRIS detector, the detector simulation as well as the measuring strategies foreseen and the sensitivity levels to U/Th that can be reached in this setup.

physics.ins-det↗

Mass production and characterization of 3-inch PMTs for the JUNO experiment

26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was performed in the factory concurrently with production as a joint effort between HZC and JUNO. Fifteen performance parameters were tracked at different sampling rates, and novel working strategies were implemented to improve quality assurance. This constitutes the largest sample of 3-inch PMTs ever produced and studied in detail to date.

physics.ins-det↗

Calibration Strategy of the JUNO Experiment

We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination.

physics.ins-det↗

Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO

The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO's potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.

hep-ex↗