Searcharxiv⌕ Search

arXiv subjects

Frédéric Perrot

Publications and source records attributed to Frédéric Perrot.

6 recordsLinked to original sources

Embedded underwater front-end electronics for the 3-inch photomultipliers in the JUNO experiment

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20-kton liquid scintillator-based, low-radioactivity, multi-purpose neutrino detector located 693 meters (1800 m.w.e.) underground in the Guangdong province, China. To detect scintillation light produced in the target, the detector is equipped with 17,612 20-inch photomultipliers (PMTs), forming the Large PMT system (LPMT). In addition, 25,600 3-inch photomultipliers (the Small Photomultiplier System or SPMT) are deployed in the gaps between the LPMTs. This paper presents the design and performance of the underwater front-end electronics developed for the SPMT system. It details the individual electronics boards and their key components, the inter-board interfaces, the system-level design, and the firmware architecture that supports data acquisition and control. It also outlines mechanical and thermal integration, board validation procedures, and system performance metrics. The readout chain includes digitization of 128 PMT channels per unit, synchronized time-stamping, charge measurement, event packaging, and bandwidth management. Comprehensive validation confirms the system's readiness to meet JUNO's stringent physics goals. The underwater electronics achieve noise levels as low as 0.04 photoelectrons with minimal crosstalk (below 0.4%) and a bandwidth of 57 MB/s, ensuring reliable single photo-electron detection and operation under high-rate conditions. The SPMT system has now been fully integrated and installed in JUNO. Its commissioning and physics performance will be reported in a future publication.

physics.ins-det↗

The High Voltage Splitter board for the JUNO SPMT system

The Jiangmen Underground Neutrino Observatory (JUNO) in southern China is designed to study neutrinos from nuclear reactors and natural sources to address fundamental questions in neutrino physics. Achieving its goals requires continuous operation over a 20-year period. The small photomultiplier tube (small PMT or SPMT) system is a subsystem within the experiment composed of 25600 3-inch PMTs and their associated readout electronics. The High Voltage Splitter (HVS) is the first board on the readout chain of the SPMT system and services the PMTs by providing high voltage for biasing and by decoupling the generated physics signal from the high-voltage bias for readout, which is then fed to the front-end board. The necessity to handle high voltage, manage a large channel count, and operate stably for 20 years imposes significant constraints on the physical design of the HVS. This paper serves as a comprehensive documentation of the HVS board: its role in the SPMT readout system, the challenges in its design, performance and reliability metrics, and the methods employed for production and quality control.

physics.ins-det↗

Study on U/Th residual radioactivity in acrylic from surface treatment

Acrylic is widely used as material for the target container in low background experiments due to its high light transparency and low intrinsic radioactivity. However, its surface can be easily contaminated during production, so careful treatment of the surface is essential to avoid direct contamination of the target. The Jiangmen Underground Neutrino Observatory will use about 600~t of acrylic to build the spherical vessel of 35.4~m in diameter for a 20~kt liquid scintillator (LS). Since acrylic will contact the LS directly, the cleanliness of the its surface is quite important for the radiopurity of the LS. A new method for measuring the radioactivity of $^{238}$U and $^{232}$Th in acrylic to sub-ppt ($<10^{-12}$~g/g) was developed, and it is crucial for the acrylic radioactivity screening in this study. We performed many background tests on different surface treatments, and the recommended procedure for the treatment of acrylic to achieve low radioactivity and high light transparency could be applicable to other low background experiments.

physics.ins-det↗

Calibration Strategy of the JUNO-TAO Experiment

The Taishan Antineutrino Observatory (JUNO-TAO, or TAO) is a satellite detector for the Jiangmen Underground Neutrino Observatory (JUNO). Located near the Taishan reactor, TAO independently measures the reactor's antineutrino energy spectrum with unprecedented energy resolution. To achieve this goal, energy response must be well calibrated. Using the Automated Calibration Unit (ACU) and the Cable Loop System (CLS) of TAO, multiple radioactive sources are deployed to various positions in the detector to perform a precise calibration of energy response. The non-linear energy response can be controlled within 0.6% with different energy points of these radioactive sources. It can be further improved by using $^{12}\rm B$ decay signals produced by cosmic muons. Through the energy non-uniformity calibration, residual non-uniformity is less than 0.2%. The energy resolution degradation and energy bias caused by the residual non-uniformity can be controlled within 0.05% and 0.3%, respectively. In addition, the stability of other detector parameters, such as the gain of each silicon photo-multiplier, can be monitored with a special ultraviolet LED calibration system.

physics.ins-det↗

CATIROC: an integrated chip for neutrino experiments using photomultiplier tubes

An ASIC named CATIROC (Charge And Time Integrated Read Out Chip) has been developed for the next-generation neutrino experiments using a large number of photomultiplier tubes (PMTs). Each CATIROC provides the time and the charge measurements for 16 configurable input channels operating in trigger-less mode. Originally designed for the light emission in water Cherenkov detectors, we show in this paper that its use can be extended to liquid-scintillator based experiments. The $\sim$26000 3-inch PMTs of the JUNO experiment, under construction in China, is a case in point. This paper describes the features of CATIROC with a special attention to the most critical points for its application to the time profile of the light emission in liquid scintillators. The achieved performances in both charge and time measurements can be inputs for future high-precision experiments making use of PMTs or other photo-sensitive detectors.

physics.ins-det↗

Mass production and characterization of 3-inch PMTs for the JUNO experiment

26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was performed in the factory concurrently with production as a joint effort between HZC and JUNO. Fifteen performance parameters were tracked at different sampling rates, and novel working strategies were implemented to improve quality assurance. This constitutes the largest sample of 3-inch PMTs ever produced and studied in detail to date.

physics.ins-det↗