SearcharxivSearch

arXiv subjects

G. El Fakhri

Publications and source records attributed to G. El Fakhri.

3 recordsLinked to original sources

Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond

This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This ASIC, manufactured in 65 nm CMOS technology, can readout positive or negative polarity sensors and provides a digitized measurement of the arrival time and energy of the detected events with a power consumption of 12.5 mW per channel. On-chip digitization is executed by a Time-to-Digital Converter (TDC) based on a Phase-Locked Loop (PLL) generating 16 phases at 1.28 GHz. The internal TDC introduces a jitter contribution of 31.3 ps FWHM, with minimal impact on timing measurements. When evaluating FastIC+ to readout 3$\times$3 mm$^2$ silicon photomultipliers (SiPMs) with a pulsed laser, we achieved a single-photon time resolution (SPTR) of (98 $\pm$ 1) ps FWHM. We also performed time-of-flight positron emission tomography (ToF-PET) experiments using scintillator crystals of different sizes and materials. With LYSO:Ce,Ca crystals of 2.8$\times$2.8$\times$20 mm$^3$ we obtained a coincidence time resolution (CTR) of (130 $\pm$ 1) ps FWHM. With LGSO crystals of 2$\times$2$\times$3 mm$^3$, a CTR of (85 $\pm$ 1) ps FWHM. To the best of our knowledge, this is the first time that a CTR below 100 ps using on-chip digitization is reported.

physics.ins-det

A layered single-side readout DOI TOF-PET detector

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative offset, with inherent DOI information but good timing performance has not been shown with conventional light sharing readout. 2) Single crystal array with one-to-one coupling to the photodetector (PD) array, with good timing performance, but no DOI. We believe the combination, where the first layer of a staggered design is coupled one-to-one to a PD array may provide both DOI and timing. The concept is here evaluated through light transport simulations. Results show that: 1) In terms of DOI one-to-one readout of the first layer allows for accurate DOI extraction using a single threshold relative to the PD sum signal, for up to 4 layers. The number of PD pixels exceeding the threshold corresponds to the layer of interaction. The corresponding approach is not possible for the same geometries with a light sharing readout scheme. 2) When employing a low threshold of 2 optical photons the layered approach with one-to-one readout of the first layer improves timing close to the PD compared to single layer, due to reduced crystal thickness. Single detector timing resolution values of 91, 127, 151 and 164 ps were seen in the 4-layer design with unpolished pixels, compared to 148 ps for single array with one-to-one coupling. 3) For the layered design with light sharing readout, timing improves with increased PD pixel size, with an apparent tradeoff between spatial resolution and timing not observed for the one-to-one coupled counterpart. The combination of straightforward and accurate DOI determination, good timing performance and relatively simple design makes the proposed detector a promising candidate for brain dedicated DOI TOF-PET.

physics.ins-det

A Bayesian spatial temporal mixtures approach to kinetic parametric images in dynamic Positron Emission Tomography

We present a fully Bayesian statistical approach to the problem of compartmental modelling in the context of Positron Emission Tomography. We cluster homogeneous region of interest and perform kinetic parameter estimation simultaneously. A mixture modelling approach is adopted, incorporating both spatial and temporal information based on reconstructed dynamic PET image. Our modelling approach is flexible, and provides uncertainty estimates for the estimated kinetic parameters. Crucially, the proposed method allows us to determine the unknown number of clusters, which has a great impact on resulting estimated kinetic parameters. We demonstrate our method on simulated dynamic Myocardial PET data, and show that our method is superior to standard curve-fitting approach.

stat.AP