SearcharxivSearch

arXiv · 2007.03756

A layered single-side readout DOI TOF-PET detector

Abstract

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative offset, with inherent DOI information but good timing performance has not been shown with conventional light sharing readout. 2) Single crystal array with one-to-one coupling to the photodetector (PD) array, with good timing performance, but no DOI. We believe the combination, where the first layer of a staggered design is coupled one-to-one to a PD array may provide both DOI and timing. The concept is here evaluated through light transport simulations. Results show that: 1) In terms of DOI one-to-one readout of the first layer allows for accurate DOI extraction using a single threshold relative to the PD sum signal, for up to 4 layers. The number of PD pixels exceeding the threshold corresponds to the layer of interaction. The corresponding approach is not possible for the same geometries with a light sharing readout scheme. 2) When employing a low threshold of 2 optical photons the layered approach with one-to-one readout of the first layer improves timing close to the PD compared to single layer, due to reduced crystal thickness. Single detector timing resolution values of 91, 127, 151 and 164 ps were seen in the 4-layer design with unpolished pixels, compared to 148 ps for single array with one-to-one coupling. 3) For the layered design with light sharing readout, timing improves with increased PD pixel size, with an apparent tradeoff between spatial resolution and timing not observed for the one-to-one coupled counterpart. The combination of straightforward and accurate DOI determination, good timing performance and relatively simple design makes the proposed detector a promising candidate for brain dedicated DOI TOF-PET.

Explore related subjects

Keep this discovery

BibTeXRIS

L. Bläckberg, S. Sajedi, G. El Fakhri, H. Sabet. 2020-07-07. A layered single-side readout DOI TOF-PET detector. https://doi.org/10.1088/1361-6560/abd592

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det