SearcharxivSearch

arXiv subjects

G. Fanourakis

Publications and source records attributed to G. Fanourakis.

At least 19 recordsLinked to original sources

Exploring ESS$\nu$SB Near Water Cherenkov Detector Designs Through Graph Neural Network Flavour Identification

The ESS$\nu$SB experiment aims to measure CP violation in the leptonic sector with high precision, necessitating robust reconstruction of neutrino events in the water Cherenkov (WC) detectors. In this work, we investigate the flavour identification potential of the proposed near WC detector using graph neural network (GNN)-based classification, with a focus on variations of key detector design parameters. In particular, we study whether a smaller and/or less instrumented detector can achieve the required classification performance. Using detailed Monte Carlo simulations of charged-current (CC) neutrino interactions, we train GNN classifiers to distinguish electron and muon neutrino CC events. We find that GNN-based classification remains accurate even for detector configurations with volumes up to a factor of eight smaller than the nominal design, with only moderate degradation in classification efficiency at fixed background rejection. The resulting loss in efficiency can largely be compensated by increased exposure time. Furthermore, we demonstrate that reduced photomultiplier tube (PMT) coverage in the nominal detector has a limited impact on classification performance, provided that coverage is maintained in regions of highest signal yield, in particular near the forward end-cap.

hep-ex

Study of Supernova Neutrinos at ESSnuSB

In this paper, we have studied the sensitivity of the ESSnuSB far detector to supernova neutrinos. ESSnuSB is a proposed long-baseline neutrino experiment in Sweden, which will use a 538 kt water Cherenkov detector to probe the leptonic phase $\delta_{\rm CP}$ by studying the second oscillation maximum. However, given the very large detector volume, it will have an excellent sensitivity to supernova neutrinos if a supernova explosion occurs during the run-time of ESSnuSB. Motivated by this, we first estimate the expected event rates at the ESSnuSB far detector for three different supernova flux models and then we probe its capability to distinguish these flux models. Additionally, we also investigate the impact of systematic errors and detector efficiency. Our results show that depending on the model of the supernova neutrinos, the expected number of events detected at Earth varies significantly. Our results also show that the ESSnuSB far detector may have excellent potential in distinguishing these flux models depending upon the distance of the supernova explosion, systematic errors and detector efficiency.

hep-ex

Searching non-standard interactions with atmospheric neutrinos at ESSnuSB

Atmospheric neutrinos provide a unique avenue to study neutrino interactions in matter. In this work, the prospects of constraining non-standard neutrino interactions with atmospheric neutrino oscillations are investigated for the proposed ESSnuSB far detector. By analyzing atmospheric neutrino samples equivalent to 5.4 Mt$\cdot$year exposure, it is found that ESSnuSB could be able to set the upper bounds $|ε_{eμ}^m| < 0.053, |ε_{eτ}^m| < 0.057, |ε_{μτ}^m| < 0.021, ε_{ee}^m - ε_{μμ}^m < 0.075$ and $|ε_{ττ}^m - ε_{μμ}^m| < 0.031$ at $90\%$ CL, when the results are minimized for $ϕ_{eμ}^m, ϕ_{eτ}^m$ and $ϕ_{μτ}^m$ and normal ordering is assumed for neutrino masses. It is also shown that the presence of non-standard interactions could affect the sensitivities to neutrino mass ordering and $θ_{23}^{}$ octant in comparison to the standard interaction scheme. The results of this work highlight the complementarity between atmospheric and accelerator neutrino programs in ESSnuSB.

hep-ex

Advances in photocathode development for PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $\sigma<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The study includes laboratory measurements of optical and resistive properties, along with beam tests using 150 GeV/$c$ muons to evaluate the time resolution and photoelectron yield for various photocathodes. The best performance was obtained by a 5 nm Cesium Iodide (CsI) photocathode, reaching $\sigma = 10.9 \pm 0.3$ ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date. Metallic and carbon-based photocathodes, including Titanium (Ti), Boron Carbide (B$_4$C) and Diamond-Like Carbon (DLC), were also tested, with Ti and B$_4$C emerging as the most promising alternatives, achieving $\sigma \approx 30$ ps with about 5 extracted photoelectrons. These results demonstrate that improved robustness can be achieved while maintaining excellent time resolution, supporting the feasibility of using the PICOSEC Micromegas concept in future experiments.

physics.ins-det

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

physics.ins-det

Complementarity between atmospheric and super-beam neutrinos at ESSnuSB

The ESSnuSB experiment aims to measure the leptonic CP phase $δ_{CP}$ with an unprecedented resolution by probing neutrino oscillations at the second oscillation maximum. In the present work, the complementarity between the long-baseline neutrino program and atmospheric neutrinos is investigated for ESSnuSB. By simulating atmospheric neutrino events equivalent of 5.4 Mt$\cdot$year exposure, the resolution for $δ_{\rm CP}^{}$ is found to improve from $7.5^\circ$ ($6.7^\circ$) to $7.1^\circ$ ($6.5^\circ$) at $1σ$~CL for $δ_{\rm CP}^{} = -90^\circ$ ($+90^\circ$) with respect to super-beam neutrinos, resolving also the degeneracies arising from neutrino mass ordering. These findings highlight the synergies that exist between super-beam neutrinos and atmospheric neutrinos in ESSnuSB.

hep-ex

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based photodetector with a photocathode. This configuration allows the fast photoelectron-induced signal to suppress the intrinsic time jitter of gaseous detectors, enabling sub-20 ps timing precision while preserving the robustness and scalability of micro-pattern gaseous detector technologies. The 96-pad PICOSEC-MM detector is a large-area demonstrator optimized for precision timing in high-energy physics, building on research and development insights from earlier 7-pad resistive prototypes to validate scalability, uniformity, and robustness for the ENUBET project. It employs a 2.5 nm diamond-like carbon photocathode and a Micromegas board with a surface resistivity of 10 megaohms per square, and was characterized using 150 GeV/c muons at the CERN SPS beamline, with one-third of the active area instrumented per run. A dedicated alignment procedure for multi-pad PICOSEC-MM systems was used to reconstruct pad centers and merge measurements across regions, yielding a timing resolution of 43 ps and uniform signal arrival time distributions over the tested area. Mechanical flatness was identified as a key factor, with planarity tolerances within 10 micrometers required to maintain good timing resolution, and the successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept toward robust, high-granularity, picosecond-level gaseous timing detectors for monitored neutrino beam experiments such as ENUBET.

physics.ins-det

Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides a proof of concept for the use of resistive layer technology in gaseous timing detectors, demonstrating that robustness can be improved without compromising the excellent timing performance of PICOSEC Micromegas. Different resistive architectures and values were explored to optimize stability and ensure reliable long-term operation in challenging experimental environments. The prototype with a 10M{\Omega} resistive layer achieved the best overall performance, with a timing resolution of 22.900 {\pm} 0.002 ps and a spatial resolution of 1.190 {\pm} 0.003 mm, while charge sharing across multiple pads enabled combined timing resolutions below 28 ps. A lower-resistivity (200k{\Omega}) configuration exhibited enhanced charge spread, leading to minor systematic offsets in reconstructed pad centers, yet maintained robust timing and spatial performance. Capacitive charge-sharing architectures improved spatial resolution in some regions but suffered from signal attenuation and nonuniform charge distributions, resulting in slightly degraded timing (33.300 {\pm} 0.002 ps) and complex localization patterns. Mechanical precision, particularly readout planarity and photocathode alignment, was identified as critical for uniform detector response. These studies benchmark the potential of resistive layers for gaseous timing detectors and provide a foundation for scalable designs with optimized timing and spatial resolution across diverse experimental applications.

physics.ins-det

Probing Long-Range Forces in Neutrino Oscillations at the ESSnuSB Experiment

Neutrino oscillations constitute an excellent tool to probe physics beyond the Standard Model. In this paper, we investigate the potential of the ESSnuSB experiment to constrain the effects of flavour-dependent long-range forces (LRFs) in neutrino oscillations, which may arise due to the extension of the Standard Model gauge group by introducing new $U(1)$ symmetries. Focusing on three specific $U(1)$ symmetries -- $L_e - L_μ$, $L_e - L_τ$, and $L_μ- L_τ$, we demonstrate that ESSnuSB offers a favourable environment to search for LRF effects. Our analyses reveal that ESSnuSB can set $90\%$ confidence level bounds of $V_{eμ} < 2.99 \times 10^{-14} \, \text{eV}$, $V_{eτ} < 2.05 \times 10^{-14} \, \text{eV}$, and $V_{μτ} < 1.81 \times 10^{-14} \, \text{eV}$, which are competitive to the upcoming Deep Underground Neutrino Experiment (DUNE). It is also observed that reducing the systematic uncertainties from $5\%$ to $2\%$ improves the ESSnuSB limits on $V_{αβ}$. Interestingly, we find limited correlations between LRF parameters and the less constrained lepton mixing parameters $θ_{23}$ and $δ_{\text{CP}}$, preserving the robustness of ESSnuSB's sensitivity to CP violation. Even under extreme LRF potentials ($V_{αβ} \gg 10^{-13} \, \text{eV}$), the CP-violation sensitivity and $δ_{\text{CP}}$ precision remain largely unaffected. These results establish ESSnuSB as a competitive experimental setup for probing LRF effects, complementing constraints from other neutrino sources and offering critical insights into the physics of long-range forces.

hep-ph

Classification of Electron and Muon Neutrino Events for the ESS$ν$SB Near Water Cherenkov Detector using Graph Neural Networks

In the effort to obtain a precise measurement of leptonic CP-violation with the ESS$ν$SB experiment, accurate and fast reconstruction of detector events plays a pivotal role. In this work, we examine the possibility of replacing the currently proposed likelihood-based reconstruction method with an approach based on Graph Neural Networks (GNNs). As the likelihood-based reconstruction method is reasonably accurate but computationally expensive, one of the benefits of a Machine Learning (ML) based method is enabling fast event reconstruction in the detector development phase, allowing for easier investigation of the effects of changes to the detector design. Focusing on classification of flavour and interaction type in muon and electron events and muon- and electron neutrino interaction events, we demonstrate that the GNN reconstructs events with greater accuracy than the likelihood method for events with greater complexity, and with increased speed for all events. Additionally, we investigate the key factors impacting reconstruction performance, and demonstrate how separation of events by pion production using another GNN classifier can benefit flavour classification.

hep-ex

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

physics.ins-det

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

physics.ins-det

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.

physics.ins-det

Exploring atmospheric neutrino oscillations at ESSnuSB

This study provides an analysis of atmospheric neutrino oscillations at the ESSnuSB far detector facility. The prospects of the two cylindrical Water Cherenkov detectors with a total fiducial mass of 540 kt are investigated over 10 years of data taking in the standard three-flavor oscillation scenario. We present the confidence intervals for the determination of mass ordering, $θ_{23}$ octant as well as for the precisions on $\sin^2θ_{23}$ and $|Δm_{31}^2|$. It is shown that mass ordering can be resolved by $3σ$ CL ($5σ$ CL) after 4 years (10 years) regardless of the true neutrino mass ordering. Correspondingly, the wrong $θ_{23}$ octant could be excluded by $3σ$ CL after 4 years (8 years) in the case where the true neutrino mass ordering is normal ordering (inverted ordering). The results presented in this work are complementary to the accelerator neutrino program in the ESSnuSB project.

hep-ex

Decoherence in Neutrino Oscillation at the ESSnuSB Experiment

Neutrino oscillation experiments provide a unique window in exploring several new physics scenarios beyond the standard three flavour. One such scenario is quantum decoherence in neutrino oscillation which tends to destroy the interference pattern of neutrinos reaching the far detector from the source. In this work, we study the decoherence in neutrino oscillation in the context of the ESSnuSB experiment. We consider the energy-independent decoherence parameter and derive the analytical expressions for P$_{μe}$ and P$_{μμ}$ probabilities in vacuum. We have computed the capability of ESSnuSB to put bounds on the decoherence parameters namely, $Γ_{21}$ and $Γ_{32}$ and found that the constraints on $Γ_{21}$ are competitive compared to the DUNE bounds and better than the most stringent LBL ones from MINOS/MINOS+. We have also investigated the impact of decoherence on the ESSnuSB measurement of the Dirac CP phase $δ_{\rm CP}$ and concluded that it remains robust in the presence of new physics.

hep-ex

A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

physics.ins-det

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.

physics.ins-det