Searcharxiv⌕ Search

arXiv subjects

G. Fanourakis

Publications and source records attributed to G. Fanourakis.

At least 37 records · Page 2Linked to original sources

Study of non-standard interaction mediated by a scalar field at ESSnuSB experiment

In this paper we study non-standard interactions mediated by a scalar field (SNSI) in the context of ESSnuSB experiment. In particular we study the capability of ESSnuSB to put bounds on the SNSI parameters and also study the impact of SNSI in the measurement of the leptonic CP phase $δ_{\rm CP}$. Existence of SNSI modifies the neutrino mass matrix and this modification can be expressed in terms of three diagonal real parameters ($η_{ee}$, $η_{μμ}$ and $η_{ττ}$) and three off-diagonal complex parameters ($η_{e μ}$, $η_{eτ}$ and $η_{μτ}$). Our study shows that the upper bounds on the parameters $η_{μμ}$, $η_{ττ}$ and $η_{μτ}$ depend upon how $Δm^2_{31}$ is minimized in the theory. However, this is not the case when one tries to measure the impact of SNSI on $δ_{\rm CP}$. Further, we show that the CP sensitivity of ESSnuSB can be completely lost for certain values of $η_{ee}$ and $η_{μτ}$ for which the appearance channel probability becomes independent of $δ_{\rm CP}$.

hep-ex↗

Particle Physics at the European Spallation Source

Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons and neutrinos produced at the ESS for high precision (sensitivity) measurements (searches).

physics.ins-det↗

The ESSnuSB design study: overview and future prospects

ESSnuSB is a design study for an experiment to measure the CP violation in the leptonic sector at the second neutrino oscillation maximum using a neutrino beam driven by the uniquely powerful ESS linear accelerator. The reduced impact of systematic errors on sensitivity at the second maximum allows for a very precise measurement of the CP violating parameter. This review describes the fundamental advantages of measurement at the 2nd maximum, the necessary upgrades to the ESS linac in order to produce a neutrino beam, the near and far detector complexes, the expected physics reach of the proposed ESSnuSB experiment, concluding with the near future developments aimed at the project realization.

hep-ex↗

Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes

Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stochastically the dynamics of the signal formation, new PICOSEC designs were developed that significantly improve the timing performance of the detector. PICOSEC prototypes with reduced drift gap size ($\sim$\SI{119}{\micro\metre}) achieved a resolution of 45\,ps in timing single photons in laser beam tests (in comparison to 76\,ps of the standard PICOSEC detector). Towards large area detectors, multi-pad PICOSEC prototypes with segmented anodes has been developed and studied. Extensive tests in particle beams revealed that the multi-pad PICOSEC technology provides also very precise timing, even when the induced signal is shared among several neighbouring pads. Furthermore, new signal processing algorithms have been developed, which can be applied during data acquisition and provide real time, precise timing.

physics.ins-det↗

The European Spallation Source neutrino Super Beam Conceptual Design Report

This conceptual design report provides a detailed account of the European Spallation Source neutrino Super Beam (ESS$ν$SB) feasibility study. This facility has been proposed after the measurements reported in 2012 of a relatively large value of the neutrino mixing angle $θ_{13}$, which raised the possibility of observing potential CP violation in the leptonic sector with conventional neutrino beams. The measured value of $θ_{13}$ also privileges the $2^{nd}$ oscillation maximum for the discovery of CP violation instead of the more typically studied $1^{st}$ maximum. The sensitivity at this $2^{nd}$ oscillation maximum is about three times higher than at the $1^{st}$ one, which implies a reduced influence of systematic errors. Working at the $2^{nd}$ oscillation maximum requires a very intense neutrino beam with an appropriate energy. The world's most intense pulsed spallation neutron source, the European Spallation Source (ESS), will have a proton linac operating at 5\,MW power, 2\,GeV kinetic energy and 14~Hz repetition rate (3~ms pulse duration, 4\% duty cycle) for neutron production. In this design study it is proposed to double the repetition rate and compress the beam pulses to the level of microseconds in order to provide an additional 5~MW proton beam for neutrino production. The physics performance has been evaluated for such a neutrino super beam, in conjunction with a megaton-scale underground water Cherenkov neutrino detector installed at a distance of 360--550\,km from ESS. The ESS proton linac upgrades, the accumulator ring required for proton-pulse compression, the target station design and optimisation, the near and far detector complexes, and the physics potential of the facility are all described in this report. The ESS linac will be operational by 2025, at which point the implementation of upgrades for the neutrino facility could begin.

hep-ex↗

Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.

physics.ins-det↗

The European Spallation Source neutrino Super Beam

In this Snowmass 2021 white paper, we summarise the Conceptual Design of the European Spallation Source neutrino Super Beam (ESSvSB) experiment and its synergies with the possible future muon based facilities, e.g. a Low Energy nuSTORM and the Muon Collider. The ESSvSB will benefit from the high power, 5 MW, of the European Spallation Source (ESS) LINAC in Lund-Sweden to produce the world most intense neutrino beam, enabling measurements to be made at the second oscillation maximum. Assuming a ten-year exposure, physics simulations show that the CP-invariance violation can be established with a significance of 5 sigma over more than 70% of all values of delta CP and with an error in the measurement of the delta CP angle of less than 8 degree for all values of delta CP. However, several technological and physics challenges must be further studied before achieving a final Technical Design. Measuring at the 2nd oscillation maximum necessitates a very intense neutrino beam with the appropriate energy. For this, the ESS proton beam LINAC, which is designed to produce the world's most intense neutron beam, will need to be upgraded to 10 MW power, 2.5 GeV energy and 28 Hz beam pulse repetition rate. An accumulator ring will be required for the compression of the ESS LINAC beam pulse from 2.86 ms to 1.3 mus. A high power target station facility will be needed to produce a well-focused intense (super) mu-neutrino beam. The physics performance of that neutrino Super Beam in conjunction with a megaton underground Water Cherenkov neutrino far detector installed at a distance of either 360 km or 540 km from the ESS, the baseline, has been evaluated.

physics.acc-ph↗

Updated physics performance of the ESSnuSB experiment

In this paper, we present the physics performance of the ESSnuSB experiment in the standard three flavor scenario using the updated neutrino flux calculated specifically for the ESSnuSB configuration and updated migration matrices for the far detector. Taking conservative systematic uncertainties corresponding to a normalization error of $5\%$ for signal and $10\%$ for background, we find that there is $10σ$ $(13σ)$ CP violation discovery sensitivity for the baseline option of 540 km (360 km) at $δ_{\rm CP} = \pm 90^\circ$. The corresponding fraction of $δ_{\rm CP}$ for which CP violation can be discovered at more than $5 σ$ is $70\%$. Regarding CP precision measurements, the $1σ$ error associated with $δ_{\rm CP} = 0^\circ$ is around $5^\circ$ and with $δ_{\rm CP} = -90^\circ$ is around $14^\circ$ $(7^\circ)$ for the baseline option of 540 km (360 km). For hierarchy sensitivity, one can have $3σ$ sensitivity for 540 km baseline except $δ_{\rm CP} = \pm 90^\circ$ and $5σ$ sensitivity for 360 km baseline for all values of $δ_{\rm CP}$. The octant of $θ_{23}$ can be determined at $3 σ$ for the values of: $θ_{23} > 51^\circ$ ($θ_{23} < 42^\circ$ and $θ_{23} > 49^\circ$) for baseline of 540 km (360 km). Regarding measurement precision of the atmospheric mixing parameters, the allowed values at $3 σ$ are: $40^\circ < θ_{23} < 52^\circ$ ($42^\circ < θ_{23} < 51.5^\circ$) and $2.485 \times 10^{-3}$ eV$^2 < Δm^2_{31} < 2.545 \times 10^{-3}$ eV$^2$ ($2.49 \times 10^{-3}$ eV$^2 < Δm^2_{31} < 2.54 \times 10^{-3}$ eV$^2$) for the baseline of 540 km (360 km).

hep-ex↗

Timing performance of a multi-pad PICOSEC-Micromegas detector prototype

The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we measure a time resolution of approximately 25 picoseconds for charged particles hitting near the anode pad centers, and up to 30 picoseconds at the pad edges. Here, we study in detail the effect of drift gap thickness non-uniformity on the timing performance and evaluate impact position based corrections to obtain a uniform timing response over the full detector coverage.

physics.ins-det↗

Modeling the Timing Characteristics of the PICOSEC Micromegas Detector

The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations based on GARFIELD++ reproduce the experimental PICOSEC timing characteristics. This agreement is exploited to identify the microscopic physical variables, which determine the observed timing properties. In these studies, several counter-intuitive observations are made for the behavior of such microscopic variables. In order to gain insight on the main physical mechanisms causing the observed behavior, a phenomenological model is constructed and presented. The model is based on a simple mechanism of "time-gain per interaction" and it employs a statistical description of the avalanche evolution. It describes quantitatively the dynamical and statistical properties of the microscopic quantities, which determine the PICOSEC timing characteristics, in excellent agreement with the simulations. In parallel, it offers phenomenological explanations for the behavior of these microscopic variables. The formulae expressing this model can be used as a tool for fast and reliable predictions, provided that the input parameter values (e.g. drift velocities) are known for the considered operating conditions.

physics.ins-det↗

Precise Charged Particle Timing with the PICOSEC Detector

The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called PICOSEC, which is based to a "two-stage" MicroMegas detector coupled to a Cherenkov radiator equipped with a photocathode has been developed. Results obtained with this new detector yield a time resolution of 24\,ps for 150\,GeV muons and 76\,ps for single photoelectrons. In this paper we will report on the performance of the PICOSEC in test beams, as well as simulation studies and modelling of its timing characteristics.

physics.ins-det↗

Improved Search for Solar Chameleons with a GridPix Detector at CAST

We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, $β_γ< 5.7\times10^{10}$ for $1<β_\mathrm{m}<10^6$ at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to $12.5\,\mathrm{T}$.

hep-ex↗

Charged particle timing at sub-25 picosecond precision: the PICOSEC detection concept

The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at the CERN SPS H4 secondary line. This work will present the main results of this prototype and the performance of the different detector configurations tested in 2016-18 beam campaigns: readouts (bulk, resistive, multipad) and photocathodes (metallic+CsI, pure metallic, diamond). Finally, the prospects for building a demonstrator based on PICOSEC detection concept for future experiments will be discussed. In particular, the scaling strategies for a large area coverage with a multichannel readout plane, the R\&D on solid converters for building a robust photocathode and the different resistive configurations for a robust readout.

physics.ins-det↗

PICOSEC: Charged particle timing at sub-25 picosecond precision with a Micromegas based detector

The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to significant reduction of these backgrounds. With this goal, we present a new detection concept called PICOSEC, which is based on a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. First results obtained with this new detector yield a time resolution of 24 ps for 150 GeV muons, and 76 ps for single photoelectrons.

physics.ins-det↗

New CAST Limit on the Axion-Photon Interaction

During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a world leading limit of $g_{aγ} < 0.66 \times 10^{-10} {\rm GeV}^{-1}$ (95% C.L.) on the axion-photon coupling strength for $m_a \lesssim 0.02$ eV. Compared with the first vacuum phase (2003--2004), the sensitivity was vastly increased with low-background x-ray detectors and a new x-ray telescope. These innovations also serve as pathfinders for a possible next-generation axion helioscope.

hep-ex↗

Search for chameleons with CAST

In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($β_{\rm m}$) and to photons ($β_γ$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to the converted solar chameleon spectrum which peaks around 600$\,$eV. Even though we have not observed any excess above background, we can provide a 95% C.L. limit for the coupling strength of chameleons to photons of $β_γ\!\lesssim\!10^{11}$ for $1<β_{\rm m}<10^6$.

astro-ph.SR↗

New solar axion search in CAST with $^4$He filling

The CERN Axion Solar Telescope (CAST) searches for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the X-ray refractive mass $m_γ$ to the axion search mass $m_a$. After the vacuum phase (2003--2004), which is optimal for $m_a\lesssim0.02$ eV, we used $^4$He in 2005--2007 to cover the mass range of 0.02--0.39 eV and $^3$He in 2009--2011 to scan from 0.39--1.17 eV. After improving the detectors and shielding, we returned to $^4$He in 2012 to investigate a narrow $m_a$ range around 0.2 eV ("candidate setting" of our earlier search) and 0.39--0.42 eV, the upper axion mass range reachable with $^4$He, to "cross the axion line" for the KSVZ model. We have improved the limit on the axion-photon coupling to $g_{aγ}< 1.47\times10^{-10} {\rm GeV}^{-1}$ (95% C.L.), depending on the pressure settings. Since 2013, we have returned to vacuum and aim for a significant increase in sensitivity.

hep-ex↗

A Storage Ring Experiment to Detect a Proton Electric Dipole Moment

A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000~TeV.

physics.acc-ph↗