SearcharxivSearch

arXiv subjects

G. Signorelli

Publications and source records attributed to G. Signorelli.

At least 37 records · Page 2Linked to original sources

Improved muon decay simulation with McMule and Geant4

The physics programme of the MEG II experiment can be extended with the search for new invisible particles produced in rare muon decays. The hunt for such elusive signals requires accurate simulations to characterise the detector response and estimate the experimental sensitivity. This work presents an improved simulation of muon decay in MEG II, based on McMule and Geant4.

hep-ex

The measuring systems of the wire tension for the MEG II Drift Chamber by means of the resonant frequency technique

The ultra-low mass cylindrical drift chamber designed for the MEG II experiment is a challenging apparatus made of 1728 phi = 20 micron gold plated tungsten sense wires, 7680 phi = 40 micron and 2496 phi = 50 micron silver plated aluminum field wires. Because of electrostatic stability requirements all the wires have to be stretched at mechanical tensions of about 25, 19 and 29 g respectively which must be controlled at a level better than 0.5 g. This chamber is presently in acquisition, but during its construction about 100 field wires broke, because of chemical corrosion induced by the atmospheric humidity. On the basis of the experience gained with this chamber we decided to build a new one, equipped with a different type of wires less sensitive to corrosion. The choice of the new wire required a deep inspection of its characteristics and one of the main tools for doing this is a system for measuring the wire tension by means of the resonant frequency technique, which is described in this paper. The system forces the wires to oscillate by applying a sinusoidal signal at a known frequency, and then measures the variation of the capacitance between a wire and a common ground plane as a function of the external signal frequency. We present the details of the measuring system and the results obtained by scanning the mechanical tensions of two samples of MEG II cylindrical drift chamber wires and discuss the possible improvements of the experimental apparatus and of the measuring technique.

physics.ins-det

Polarization angle requirements for CMB B-mode experiments. Application to the LiteBIRD satellite

A methodology to provide the polarization angle requirements for different sets of detectors, at a given frequency of a CMB polarization experiment, is presented. The uncertainties in the polarization angle of each detector set are related to a given bias on the tensor-to-scalar ratio $r$ parameter. The approach is grounded in using a linear combination of the detector sets to obtain the CMB polarization signal. In addition, assuming that the uncertainties on the polarization angle are in the small angle limit (lower than a few degrees), it is possible to derive analytic expressions to establish the requirements. The methodology also accounts for possible correlations among detectors, that may originate from the optics, wafers, etc. The approach is applied to the LiteBIRD space mission. We show that, for the most restrictive case (i.e., full correlation of the polarization angle systematics among detector sets), the requirements on the polarization angle uncertainties are of around 1 arcmin at the most sensitive frequency bands (i.e., $\approx 150$ GHz) and of few tens of arcmin at the lowest (i.e., $\approx 40$ GHz) and highest (i.e., $\approx 400$ GHz) observational bands. Conversely, for the least restrictive case (i.e., no correlation of the polarization angle systematics among detector sets), the requirements are $\approx 5$ times less restrictive than for the previous scenario. At the global and the telescope levels, polarization angle knowledge of a few arcmins is sufficient for correlated global systematic errors and can be relaxed by a factor of two for fully uncorrelated errors in detector polarization angle. The reported uncertainty levels are needed in order to have the bias on $r$ due to systematics below the limit established by the LiteBIRD collaboration.

astro-ph.CO

Detailed analysis of chemical corrosion of ultra-thin wires used in drift chamber detectors

Ultra-thin metallic anodic and cathodic wires are frequently employed in low-mass gaseous detectors for precision experiments, where the amount of material crossed by charged particles must be minimised. We present here the results of an analysis of the mechanical stress and chemical corrosion effects observed in $40$ and $50~{\rm{μm}}$ diameter silver plated aluminum wires mounted within the volume of the MEG\,II drift chamber, which caused the breaking of about one hundred wires (over a total of $\approx 12000$). This analysis is based on the accurate inspection of the broken wires by means of optical and electronic microscopes and on a detailed recording of all breaking accidents. We present a simple empirical model which relates the number of broken wires to their exposure time to atmospheric humidity and to their mechanical tension, which is necessary for mechanical stability in the presence of electrostatic fields of several kV/cm. Finally we discuss how wire breakings can be avoided or at least strongly reduced by operating in controlled atmosphere during the mounting stages of the wires within the drift chamber and by choosing a $25\,\%$ thicker wire diameter, which has very small effects on the detector resolution and efficiency and can be obtained by using a safer fabrication technique.

physics.ins-det

The large scale polarization explorer (LSPE) for CMB measurements: performance forecast

[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: Strip, a radiometer-based telescope on the ground in Tenerife, and SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2021/22 for SWIPE, with a flight duration up to 15 days, and in Summer 2021 with two years observations for Strip. We describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact into performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE can reach a sensitivity in tensor-to-scalar ratio of $σ_r<0.01$, and improve constrains on other cosmological parameters.

astro-ph.IM

Search for lepton flavour violating muon decay mediated by a new light particle in the MEG experiment

We present the first direct search for lepton flavour violating muon decay mediated by a new light particle X, $μ^+ \to \mathrm{e}^+\mathrm{X}, \mathrm{X} \to γγ$. This search uses a dataset resulting from $7.5\times 10^{14}$ stopped muons collected by the MEG experiment at the Paul Scherrer Institut in the period 2009--2013. No significant excess is found in the mass region 20--45 MeV/c$^2$ for lifetimes below 40 ps, and we set the most stringent branching ratio upper limits in the mass region of 20--40 MeV/c$^2$, down to $\mathcal{O}(10^{-11})$ at 90\% confidence level.

hep-ex

The Drift Chamber of the MEG II experiment

The MEG experiment at the Paul Scherrer Institut searches for the charged-Lepton-Flavor-Violating mu+ -> e+ gamma decay. MEG has already set the world best upper limit on the branching ratio: BR<4.2x10^-13 @ 90% C.l. An upgrade (MEG II) of the whole detector has been approved to obtain a substantial increase of sensitivity. Currently MEG II is completing the upgrade of the various detectors, an engineering run and a pre-commissioning run were carried out during 2018 and 2019. The new positron tracker is a unique volume, ultra-light He based cylindrical drift chamber (CDCH), with high granularity: 9 layers of 192 square drift cells, ~6-9 mm wide, consist of ~12000 wires in a full stereo configuration. To ensure the electrostatic stability of the drift cells a new wiring strategy should be developed due to the high wire density (12 wires/cm^2 ), the stringent precision requirements on the wire position and uniformity of the wire mechanical tension (better than 0.5 g) The basic idea is to create multiwire frames, by soldering a set of (16 or 32) wires on 40 um thick custom wire-PCBs. Multiwire frames and PEEK spacers are overlapped alternately along the radius, to set the proper cell width, in each of the twelve sectors defined by the spokes of the rudder wheel shaped end-plates. Despite to the conceptual simplicity of the assembling strategies, the building of the multiwire frames, with the set requirements, imposes a use of an automatic wiring system. The MEG II CDCH is the first cylindrical drift chamber ever designed and built in a modular way and it will allow to track positrons, with a momentum greater than 45 MeV/c, with high efficiency by using a very small amount of material, 1.5x10^-3 X0 . We describe the CDCH design and construction, the wiring phase at INFN-Lecce, the choice of the wires, their mechanical properties, the assembly and sealing at INFN-Pisa and the commissioning.

physics.ins-det

Progress report on the Large Scale Polarization Explorer

The Large Scale Polarization Explorer (LSPE) is a cosmology program for the measurement of large scale curl-like features (B-modes) in the polarization of the Cosmic Microwave Background. Its goal is to constrain the background of inflationary gravity waves traveling through the universe at the time of matter-radiation decoupling. The two instruments of LSPE are meant to synergically operate by covering a large portion of the northern microwave sky. LSPE/STRIP is a coherent array of receivers planned to be operated from the Teide Observatory in Tenerife, for the control and characterization of the low-frequency polarized signals of galactic origin; LSPE/SWIPE is a balloon-borne bolometric polarimeter based on 330 large throughput multi-moded detectors, designed to measure the CMB polarization at 150 GHz and to monitor the polarized emission by galactic dust above 200 GHz. The combined performance and the expected level of systematics mitigation will allow LSPE to constrain primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report the status of the STRIP pre-commissioning phase and the progress in the characterization of the key subsystems of the SWIPE payload (namely the cryogenic polarization modulation unit and the multi-moded TES pixels) prior to receiver integration.

astro-ph.IM

The new drift chamber of the MEG II experiment

This article presents the MEG II Cylindrical Drift CHamber (CDCH), a key detector for the phase 2 of MEG, which aims at reaching a sensitivity level of the order of $6 \times 10^{-14}$ for the charged Lepton Flavour Violating $μ^+ \rightarrow \mbox{e}^+ γ$ decay. CDCH is designed to overcome the limitations of the MEG $\mbox{e}^+$ tracker and guarantee the proper operation at high rates with long-term detector stability. CDCH is a low-mass unique volume detector with high granularity: 9 layers of 192 drift cells, few mm wide, defined by $\approx 12000$ wires in a stereo configuration for longitudinal hit localization. The total radiation length is $1.5 \times 10^{-3}$ $\mbox{X}_0$, thus minimizing the Multiple Coulomb Scattering (MCS) contribution and allowing for a single-hit resolution of 110 $μ$m and a momentum resolution of 130 keV/c. CDCH integration into the MEG II experimental apparatus will start in this year.

physics.ins-det

Commissioning of the MEG II tracker system

The MEG experiment at the Paul Scherrer Institut (PSI) represents the state of the art in the search for the charged Lepton Flavour Violating (cLFV) $μ^+ \rightarrow e^+ γ$ decay. With the phase 1, MEG set the new world best upper limit on the $\mbox{BR}(μ^+ \rightarrow e^+ γ) < 4.2 \times 10^{-13}$ (90% C.L.). With the phase 2, MEG II, the experiment aims at reaching a sensitivity enhancement of about one order of magnitude compared to the previous MEG result. The new Cylindrical Drift CHamber (CDCH) is a key detector for MEG II. CDCH is a low-mass single volume detector with high granularity: 9 layers of 192 drift cells, few mm wide, defined by $\sim 12000$ wires in a stereo configuration for longitudinal hit localization. The filling gas mixture is Helium:Isobutane (90:10). The total radiation length is $1.5 \times 10^{-3}$ $\mbox{X}_0$, thus minimizing the Multiple Coulomb Scattering (MCS) contribution and allowing for a single-hit resolution $< 120$ $μ$m and an angular and momentum resolutions of 6 mrad and 90 keV/c respectively. This article presents the CDCH commissioning activities at PSI after the wiring phase at INFN Lecce and the assembly phase at INFN Pisa. The endcaps preparation, HV tests and conditioning of the chamber are described, aiming at reaching the final stable working point. The integration into the MEG II experimental apparatus is described, in view of the first data taking with cosmic rays and $μ^+$ beam during the 2018 and 2019 engineering runs. The first gas gain results are also shown. A full engineering run with all the upgraded detectors and the complete DAQ electronics is expected to start in 2020, followed by three years of physics data taking.

physics.ins-det

Gas Distribution and Monitoring for the Drift Chamber of the MEG-II Experiment

The reconstruction of the positron trajectory in the MEG-II experiment searching for the $μ^+ \to e^+ γ$ decay uses a cylindrical drift chamber operated with a helium-isobutane gas mixture. A stable performance of the detector in terms of its electron drift properties, avalanche multiplication, and with a gas mixture of controlled composition and purity has to be provided and continuously monitored. In this paper we describe the strategies adopted to meet the requirements imposed by the target sensitivity of MEG-II, including the construction and commissioning of a small chamber for an online monitoring of the gas quality.

physics.ins-det

The design of the MEG II experiment

The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation for the upgrade and a detailed overview of the design of the experiment and of the expected detector performance.

physics.ins-det

Exploring Cosmic Origins with CORE: The Instrument

We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a medium-size space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffraction-limited Kinetic Inductance Detectors to cover the frequency range from 60 GHz to 600 GHz in 19 wide bands, in the focal plane of a 1.2 m aperture telescope cooled at 40 K, allowing for an accurate extraction of the CMB signal from polarized foreground emission. The projected CMB polarization survey sensitivity of this instrument, after foregrounds removal, is 1.7 μK$\cdot$arcmin. The design is robust enough to allow, if needed, a downscoped version of the instrument covering the 100 GHz to 600 GHz range with a 0.8 m aperture telescope cooled at 85 K, with a projected CMB polarization survey sensitivity of 3.2 μK$\cdot$arcmin.

astro-ph.IM

Single-hit resolution measurement with MEG II drift chamber prototypes

Drift chambers operated with helium-based gas mixtures represent a common solution for tracking charged particles keeping the material budget in the sensitive volume to a minimum. The drawback of this solution is the worsening of the spatial resolution due to primary ionisation fluctuations, which is a limiting factor for high granularity drift chambers like the MEG II tracker. We report on the measurements performed on three different prototypes of the MEG II drift chamber aimed at determining the achievable single-hit resolution. The prototypes were operated with helium/isobutane gas mixtures and exposed to cosmic rays, electron beams and radioactive sources. Direct measurements of the single hit resolution performed with an external tracker returned a value of 110 $μ$m, consistent with the values obtained with indirect measurements performed with the other prototypes.

physics.ins-det

Muon polarization in the MEG experiment: predictions and measurements

The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be $P_μ = -1$ by the Standard Model (SM) with massless neutrinos. We estimated our residual muon polarization to be $P_μ = -0.85 \pm 0.03 ~ {\rm (stat)} ~ { }^{+ 0.04}_{-0.05} ~ {\rm (syst)}$ at the stopping target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our ${\megsign}$ search induced by the muon radiative decay: $μ^{+} \rightarrow {\rm e}^{+} \barν_μ ν_{\rm e} γ$.

hep-ex

Measurement of the radiative decay of polarized muons in the MEG experiment

We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_γ > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for $μ^+ \to e^+γ$ process.

hep-ex

New constraint on the existence of the mu+-> e+ gamma decay

The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.

hep-ex

The MEG detector for $μ+\to e+γ$ decay search

The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.

physics.ins-det