SearcharxivSearch

arXiv subjects

G. Signorelli

Publications and source records attributed to G. Signorelli.

46 records · Page 3Linked to original sources

MEG Upgrade Proposal

We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stopping target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.

physics.ins-det

New limit on the lepton-flavour violating decay mu -> e gamma

We present a new result based on an analysis of the data collected by the MEG detector at the Paul Scherrer Institut in 2009 and 2010, in search of the lepton flavour violating decay mu->e gamma. The likelihood analysis of the combined data sample, which corresponds to a total of 1.8 x 10**14 muon decays, gives a 90% C.L. upper limit of 2.4 x 10**-12 on the branching ratio of the mu->e gamma decay, constituting the most stringent limit on the existence of this decay to date.

hep-ex

A limit for the mu -> e gamma decay from the MEG experiment

A search for the decay mu -> e gamma, performed at PSI and based on data from the initial three months of operation of the MEG experiment, yields an upper limit on the branching ratio of BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.). This corresponds to the measurement of positrons and photons from ~ 10**14 stopped mu-decays by means of a superconducting positron spectrometer and a 900 litre liquid xenon photon detector.

hep-ex

Absorption of Scintillation Light in a 100 $\ell$ Liquid Xenon$γ$ Ray Detector and Expected Detector Performance

An 800L liquid xenon scintillation $γ$ ray detector is being developed for the MEG experiment which will search for $μ^+\to\mathrm{e}^+γ$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm$^3$ to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and $α$ sources. By using a suitable purification technique, an absorption length longer than 100 cm has been achieved. The effects of the light absorption on the energy resolution are estimated by Monte Carlo simulation.

physics.ins-det

Liquid Xe scintillation calorimetry and Xe optical properties

The optical properties of LXe in the vacuum ultra violet (VUV), determining the performance of a scintillation calorimeter, are discussed in detail. The available data, measured in a wider spectral region from visible to UV light, and in a large range of Xe densities, from gas to liquid, are examined. It is shown that this information can be used for deriving the LXe optical properties in the VUV. A comparison is made with the few direct measurements in LXe for VUV light resulting from the LXe excitation by ionizing particles. A useful relation is obtained which connects the Rayleigh scattering length to the refractive index in LXe.

physics.ins-det

B Physics at the Tevatron: Run II and Beyond

This report provides a comprehensive overview of the prospects for B physics at the Tevatron. The work was carried out during a series of workshops starting in September 1999. There were four working groups: 1) CP Violation, 2) Rare and Semileptonic Decays, 3) Mixing and Lifetimes, 4) Production, Fragmentation and Spectroscopy. The report also includes introductory chapters on theoretical and experimental tools emphasizing aspects of B physics specific to hadron colliders, as well as overviews of the CDF, D0, and BTeV detectors, and a Summary.

hep-ph

Acoustic Nature of the Boson Peak in Vitreous Silica

New temperature dependent inelastic x-ray (IXS) and Raman (RS) scattering data are compared to each other and with existing inelastic neutron scattering data in vitreous silica (v-SiO_2), in the 300 - 1775 K region. The IXS data show collective propagating excitations up to Q=3.5 nm^-1. The temperature behaviour of the excitations at Q=1.6 nm^-1 matches that of the boson peak found in INS and RS. This supports the acoustic origin of the excess of vibrational states giving rise to the boson peak in this glass.

cond-mat.dis-nn

Raman scattering from fractals. Simulation on large structures by the method of moments

We have employed the method of spectral moments to study the density of vibrational states and the Raman coupling coefficient of large 2- and 3- dimensional percolators at threshold and at higher concentration. We first discuss the over-and under-flow problems of the procedure which arise when -like in the present case- it is necessary to calculate a few thousand moments. Then we report on the numerical results; these show that different scattering mechanisms, all {\it a priori} equally probable in real systems, produce largely different coupling coefficients with different frequency dependence. Our results are compared with existing scaling theories of Raman scattering. The situation that emerges is complex; on the one hand, there is indication that the existing theory is not satisfactory; on the other hand, the simulations above threshold show that in this case the coupling coefficients have very little resemblance, if any, with the same quantities at threshold.

cond-mat

ORIGIN OF LIGHT SCATTERING FROM DISORDERED SYSTEMS

Anelastic light scattering is computed numerically for model disordered systems (linear chains and 2-dimensional site and bond percolators), with and without electrical disorder. A detailed analysis of the vibrational modes and of their Raman activity evidences that two extreme mechanisms for scattering may be singled out. One of these resembles scattering from finite size systems, while the other mechanisms originates from spatial fluctuations of the polarizability and is such that modes in even small frequency intervals may have very different Raman activities. As a consequence, the average coupling coefficient $C(ω)$ is the variance of a zero-average quantity. Our analysis shows that for both linear chains and 2-dimensional percolators the second mechanism dominates over the first, and therefore Raman scattering from disordered systems is essentially due to spatial fluctuations.

cond-mat

Absence of Definite Scaling Laws in Raman Scattering from Fractals

The frequency dependence of the Raman coupling coefficient $C(ω)$ is calculated numerically for square and cubic percolation clusters. No general scaling law in terms of the macroscopic parameters such as the fractal dimension $D$ or the spectral dimension $\overline d$ is found. $C(ω)$ is sensitive to the microscopic structure of the clusters and depends on: site- or bond-percolation, presence or absence of dangling bonds, scattering mechanism and polarization, presence or absence of polarizability disorder. This situation makes the derivation of macroscopic parameters from Raman experiments unreliable.

cond-mat