SearcharxivSearch

arXiv subjects

Gary Varner

Publications and source records attributed to Gary Varner.

12 recordsLinked to original sources

Migration of Belle II TOP Feature Extraction from the Zynq Processing System to PCIe40 Readout PCs

The Belle II Time-of-Propagation (TOP) detector is a key system for charged-particle identification (PID). Although TOP operated successfully during initial Belle II data taking, increasing luminosity and beam-induced background led to more frequent single-event upsets (SEUs) in the radiation-exposed Zynq systems-on-chip (SoCs). Resulting lockups of the embedded processing systems (PSs) interrupted data acquisition. To mitigate this limitation, waveform feature extraction, a critical task of the on-detector Zynq PS, was migrated to the off-detector PCIe40 readout PCs (ROPCs). The new architecture bypasses the PS in the event data path and performs feature extraction outside the detector radiation environment. This change removed SEU-induced PS lockups from the event data path and enabled stable operation of the TOP front-end electronics and the Belle II data-acquisition system under increased luminosity and background conditions. The typical TOP deadtime decreased from about 1% to a level consistent with zero after the final firmware patch, and stable operation was demonstrated at a Level-1 (L1) trigger rate of 30 kHz with a microchannel-plate photomultiplier-tube (MCP-PMT) hit rate of approximately 5 MHz per PMT. This paper describes the migrated architecture, its deployment and validation, and its operational and PID performance.

physics.ins-det

Development of a Silicon-Based Ultra-Fast X-Ray Beam Size Monitor for SuperKEKB

We present the development of a silicon-based ultra-fast X-ray beam size monitor (SiXRM) for SuperKEKB. The system enables, for the first time at SuperKEKB, bunch-by-bunch measurements of the vertical beam size using synchrotron radiation. The detector combines a silicon strip sensor board, amplifier boards, and fast waveform readout electronics. Beam measurements demonstrate clear reconstruction of the bunch structure and X-ray images for individual bunches. The measured beam sizes show good agreement with those obtained from the existing CMOS-based XRM system. The measurement precision is estimated to be better than 6.4 $\mu$m. This system provides a powerful tool for studying beam dynamics and optimizing luminosity in high-luminosity colliders.

physics.ins-det

The Imaging Time-of-Propagation Detector at Belle II

We report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB $e^+e^-$ collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/$c$. To date, the detector has been used to record and analyze almost 600 fb$^{-1}$ of Belle II data.

hep-ex

Radio Detection of Ultra-high Energy Cosmic Rays with Low Lunar Orbiting SmallSats

Ultra-high energy cosmic rays (UHECRs) are the most energetic particles observed and serve as a probe of the extreme universe. A key question to understanding the violent processes responsible for their acceleration is identifying which classes of astrophysical objects (active galactic nuclei or starburst galaxies, for example) correlate to their arrival directions. While source clustering is limited by deflections in the Galactic magnetic field, at the highest energies the scattering angles are sufficiently low to retain correlation with source catalogues. While there have been several studies attempting to identify source catalogue correlations with data from the Pierre Auger Observatory and the Telescope Array, the significance above an isotropic background has not yet reached the threshold for discovery. It has been known for several decades that a full-sky UHECR observatory would provide a substantial increase in sensitivity to the anisotropic component of UHECRs. There have been several concepts developed in that time targeting the identification of UHECR sources such as OWL, JEM-EUSO, and POEMMA, using fluorescence detection in the Earth's atmosphere from orbit. In this white paper, we present a concept called the Zettavolt Askaryan Polarimeter (ZAP), designed to identify the source of UHECRs using radio detection of the Askaryan radio emissions produced by UHECRs interacting in the Moon's regolith from low lunar orbit.

astro-ph.HE

Front-end electronic readout system for the Belle II imaging Time-Of-Propagation detector

The Time-Of-Propagation detector is a Cherenkov particle identification detector based on quartz radiator bars for the Belle II experiment at the SuperKEKB electron-positron collider. The purpose of the detector is to identify the type of charged hadrons produced in electron-positron collisions, and requires a single photon timing resolution below 100 picoseconds. A novel front-end electronic system was designed, built, and integrated to acquire data from the 8192 microchannel plate photomultiplier tube channels in the detector. Waveform sampling of these analog signals is done by switched-capacitor array application-specific integrated circuits. The processes of triggering, digitization of windows of interest, readout, and data transfer to the Belle II data acquisition system are managed by Xilinx Zynq-7000 programmable system on a chip devices.

physics.ins-det

A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration

The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\&D to commercialization.

physics.ins-det

A low-resolution, GSa/s streaming digitizer for a correlation-based trigger system

Searches for radio signatures of ultra-high energy neutrinos and cosmic rays could benefit from improved efficiency by using real-time beamforming or correlation triggering. For missions with power limitations, such as the ANITA-3 Antarctic balloon experiment, full speed high resolution digitization of incoming signals is not practical. To this end, the University of Hawaii has developed the Realtime Independent Three-bit Converter (RITC), a 3-channel, 3-bit, streaming analog-to-digital converter implemented in the IBM-8RF 0.13 um process. RITC is primarily designed to digitize broadband radio signals produced by the Askaryan effect, and thus targets an analog bandwidth of >1 GHz, with a sample-and-hold architecture capable of storing up to 2.6 gigasamples-per-second. An array of flash analog-to-digital converters perform 3-bit conversion of sets of stored samples while acquisition continues elsewhere in the sampling array. A serial interface is provided to access an array of on chip digital-to-analog converters that control the digitization thresholds for each channel as well as the overall sampling rate. Demultiplexed conversion outputs are read out simultaneously for each channel via a set of 36 LVDS links, each running at 650 Mb/s. We briefly describe the design architecture of RITC. Evaluation of the RITC is currently under way, and we will report testing updates as they become available, including prospects for the use of this architecture as the analog half of a novel triggering system for the ANITA-3 ultra-high energy neutrino experiment.

physics.ins-det

Development of an ASIC for Dual Mirror Telescopes of the Cherenkov Telescope Array

We have developed an application-specific integrated circui (ASIC) for photomultipler tube (PMT) waveform digitization which is well-suited for the Schwarzschild-Couder optical system under development for the Cherenkov Telescope Array (CTA) project. The key feature of the "TARGET" ASIC is the ability to read 16 channels in parallel at a sampling speed of 1 GSa/s or faster. In combination with a focal plane instrumented with 64-channel multi-anode PMTs (MAPMTs), TARGET digitizers will enable CTA to achieve a wider field of view than the current Cherenkov telescopes and significantly reduce the cost per channel of the camera and readout electronics. We have also developed a prototype camera module, consisting of 4 TARGET ASICs and a 64-channel MAPMT. We report results from performance testing of the camera module and of the TARGET ASIC itself.

astro-ph.IM

Prospects of neutrino oscillation measurements in the detection of reactor antineutrinos with a medium-baseline experiment

Despite the dramatic progress made in neutrino oscillation studies recently, several fundamental neutrino parameters remain either unknown or poorly measured. We discuss in detail a method for their measurement by precision studies of oscillation-caused neutrino energy spectrum distortions, for which a large underwater inverse beta decay detector appears to be a perfect tool. Results determine optimal baselines and necessary exposures in the presence of systematic uncertainties and the unavoidable background from terrestrial antineutrinos.

hep-ph

Signal Processing for Pico-second Resolution Timing Measurements

The development of large-area homogeneous photo-detectors with sub-millimeter path lengths for direct Cherenkov light and for secondary-electrons opens the possibility of large time-of-flight systems for relativistic particles with resolutions in the pico-second range. Modern ASIC techniques allow fast multi-channel front-end electronics capable of sub-pico-second resolution directly integrated with the photo-detectors. However, achieving resolution in the pico-second range requires a precise knowledge of the signal generation process in order to understand the pulse waveform, the signal dynamics, and the noise induced by the detector itself, as well as the noise added by the processing electronics. Using the parameters measured for fast photo-detectors such as micro-channel plates photo-multipliers, we have simulated and compared the time-resolutions for four signal processing techniques: leading edge discriminators, constant fraction discriminators, multiple-threshold discriminators and pulse waveform sampling.

physics.ins-det

High Voltage CMOS Control Interface for Astronomy - Grade Charged Coupled Devices

The Pan-STARRS telescope consists of an array of smaller mirrors viewed by a Gigapixel arrays of CCDs. These focal planes employ Orthogonal Transfer CCDs (OTCCDs) to allow on-chip image stabilization. Each OTCCD has advanced logic features that are controlled externally. A CMOS Interface Device for High Voltage has been developed to provide the appropiate voltage signal levels from a readout and control system designated STARGRASP. OTCCD chip output levels range from -3.3V to 16.7V, with two different output drive strenghts required depending on load capacitance (50pF and 1000pF), with 24mA of drive and a rise time on the order of 100ns. Additional testing ADC structures have been included in this chip to evaluate future functional additions for a next version of the chip.

physics.ins-det

PoGOLite - A High Sensitivity Balloon-Borne Soft Gamma-ray Polarimeter

We describe a new balloon-borne instrument (PoGOLite) capable of detecting 10% polarisation from 200mCrab point-like sources between 25 and 80keV in one 6 hour flight. Polarisation measurements in the soft gamma-ray band are expected to provide a powerful probe into high-energy emission mechanisms as well as the distribution of magnetic fields, radiation fields and interstellar matter. At present, only exploratory polarisation measurements have been carried out in the soft gamma-ray band. Reduction of the large background produced by cosmic-ray particles has been the biggest challenge. PoGOLite uses Compton scattering and photo-absorption in an array of 217 well-type phoswich detector cells made of plastic and BGO scintillators surrounded by a BGO anticoincidence shield and a thick polyethylene neutron shield. The narrow FOV (1.25msr) obtained with well-type phoswich detector technology and the use of thick background shields enhance the detected S/N ratio. Event selections based on recorded phototube waveforms and Compton kinematics reduce the background to that expected for a 40-100mCrab source between 25 and 50keV. A 6 hour observation on the Crab will differentiate between the Polar Cap/Slot Gap, Outer Gap, and Caustic models with greater than 5 sigma; and also cleanly identify the Compton reflection component in the Cygnus X-1 hard state. The first flight is planned for 2010 and long-duration flights from Sweden to Northern Canada are foreseen thereafter.

astro-ph