SearcharxivSearch

arXiv subjects

Gerard Visser

Publications and source records attributed to Gerard Visser.

8 recordsLinked to original sources

Design and Performance Studies of a Granular Thin HCAL-MuID Detector for the EIC Optimized for AI-Based Reconstruction

We describe the design concept and estimated performance of an iron-scintillator sampling calorimeter for the future Electron Ion Collider. The novel aspect of this detector is a multi-dimensional readout coupled with foreseen excellent timing resolution, enabling time-of-flight capabilities as well as a more compact overall assembly. Machine learning has been integrated into the detector design process from the ground up. Detector design objectives are defined using Machine Learning based reconstruction and Machine Learning is used to optimize the detector design. The highly segmented readout is implemented with Machine Learning algorithms in mind to reach performance levels usually reserved for much more expensive detector systems. The primary physics objective is to serve as a muon detector/ID system and a neutral hadron calorimeter. In EIC kinematics, charged particles are best measured through tracking rather than calorimetry, but the hKLM can identify and measure the momentum of neutral hadrons. The latter are mainly $K_L$'s and neutrons: for lower energies, excellent relative momentum measurements of a few 10\% are achieved using time of flight, while for higher particle momenta, the energy can be measured calorimetrically with a resolution significantly better than that demonstrated for similar calorimeters read out with less granularity.

physics.ins-det

The Imaging Time-of-Propagation Detector at Belle II

We report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB $e^+e^-$ collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/$c$. To date, the detector has been used to record and analyze almost 600 fb$^{-1}$ of Belle II data.

hep-ex

A High-frequency, Low-power Resonant Radio-frequency Neutron Spin Flipper for High-resolution Spectroscopy

We present a resonant-mode, transverse-field, radio-frequency (rf) neutron spin flipper design that uses high-temperature superconducting films to ensure sharp transitions between uniform magnetic field regions. Resonant mode allows for low power, high frequency operation but requires strict homogeneity of the magnetic fields inside the device. This design was found to efficiently flip neutrons at 96.6$\pm 0.6\%$ at an effective frequency of 4 MHz with a beam size of $2.5~\times~2.5$~cm and a wavelength of 0.4 nm. The high frequency and efficiency enable this device to perform high-resolution neutron spectroscopy with comparable performance to currently implemented rf flipper designs. The limitation of the maximum frequency was found due to the field homogeneity of the device. We numerically analyze the maximum possible efficiency of this design using a Bloch solver simulation with magnetic fields generated from finite-element simulations. We also discuss future improvements of the efficiency and frequency to the design based on the experimental and simulation results.

physics.ins-det

The STAR Event Plane Detector

The Event Plane Detector (EPD) is an upgrade detector to the STAR experiment at RHIC, designed to measure the pattern of forward-going charged particles emitted in a high-energy collision between heavy nuclei. It consists of two highly-segmented disks of 1.2-cm-thick scintillator embedded with wavelength-shifting fiber, coupled to silicon photomultipliers and custom electronics. We describe the general design of the device, its construction, and performance on the bench and in the experiment.

physics.ins-det

Front-end electronic readout system for the Belle II imaging Time-Of-Propagation detector

The Time-Of-Propagation detector is a Cherenkov particle identification detector based on quartz radiator bars for the Belle II experiment at the SuperKEKB electron-positron collider. The purpose of the detector is to identify the type of charged hadrons produced in electron-positron collisions, and requires a single photon timing resolution below 100 picoseconds. A novel front-end electronic system was designed, built, and integrated to acquire data from the 8192 microchannel plate photomultiplier tube channels in the detector. Waveform sampling of these analog signals is done by switched-capacitor array application-specific integrated circuits. The processes of triggering, digitization of windows of interest, readout, and data transfer to the Belle II data acquisition system are managed by Xilinx Zynq-7000 programmable system on a chip devices.

physics.ins-det

Developing a silica aerogel radiator for the HELIX ring-imaging Cherenkov system

This paper reports the successful fabrication of silica aerogel Cherenkov radiators produced in the first batches from a 96-tile mass production performed using pin-drying technique in our laboratory. The aerogels are to be used in a ring-imaging Cherenkov detector in the spectrometer of a planned balloon-borne cosmic-ray observation program, HELIX (High Energy Light Isotope eXperiment). A total of 36 transparent, hydrophobic aerogel tiles with a high refractive index of 1.16 and dimensions of 10 cm $\times $ 10 cm $\times $ 1 cm will be chosen as the flight radiators. Thus far, 40 out of the 48 tiles fabricated were confirmed as having no tile cracking. In the first screening, 8 out of the first 16 tiles were accepted as flight-qualified candidates, based on basic optical measurement results. To fit the aerogel tiles into a radiator support structure, the trimming of previously manufactured prototype tiles using a water-jet cutting device was successful.

physics.ins-det

Design and Fabrication of a Highly Integrated Silicon Detector for the STAR Experiment at Brookhaven National Laboratory

We present the design of a detector used as a particle tracking device in the STAR experiment at the RHIC collider of Brookhaven National Laboratories. The "stave," 24 of which make up the completed detector, is a highly mechanically integrated design comprised of 6 custom silicon sensors mounted on a Kapton substrate. 4608 wire bonds connect these sensors to 36 analog front-end chips which are mounted on the same substrate. Power and signal connectivity from the hybrid to the front-end chips is provided by wire bonds. The entire circuit is mounted on a carbon fiber base co-cured to the Kapton substrate. We present the unique design challenges for this detector and some novel techniques for overcoming them.

physics.ins-det

A high dynamic range data acquisition system for a solid-state electron Electric Dipole Moment experiment

We have built a high precision (24-bit) data acquisition (DAQ) system with eight simultaneously sampling input channels for the measurement of the electric dipole moment (EDM) of the electron. The DAQ system consists of two main components, a master board and eight individual analog-to-digital converter (ADC) boards. This custom DAQ system provides galvanic isolation, with fiber optic communication, between the master board and each ADC board to reduce the possibility of ground loop pickups. In addition, each ADC board is enclosed in its own heavy-duty radio frequency shielding enclosure and powered by DC batteries, to attain the ultimate low levels of channel cross-talk. In this paper, we describe the implementation of the DAQ system and scrutinize its performance.

physics.ins-det