SearcharxivSearch

arXiv subjects

Geunpil An

Publications and source records attributed to Geunpil An.

2 recordsLinked to original sources

Test-Beam Performance of the AstroPix Silicon Sensor for Imaging Calorimetry

AstroPix is a high-voltage CMOS HVCMOS monolithic active pixel sensor MAPS developed for future space-based gamma-ray missions. It is also a candidate technology for the imaging layer of the Barrel Imaging Calorimeter BIC in the ePIC experiment at the future Electron-Ion Collider EIC. We report the first AstroPix test-beam results obtained at the KEK Photon Factory Advanced Ring PF-AR and the CERN Proton Synchrotron PS T10 beam line in 2025, using the third prototype AstroPix-v3. AstroPix-v3 sensors were operated as both standalone tracking layers and imaging layers interleaved with prototype lead/scintillating-fiber Pb/SciFi calorimeter modules, using electron and hadron beams in the few-GeV/c momentum range. Event synchronization between the continuous readout of AstroPix-v3 and the trigger-based readout of the Pb/SciFi calorimeter was achieved using a common timestamp. The AstroPix-v3 sensors exhibit stable performance, reaching a maximum hit efficiency of 68 percent at a bias voltage of -400 V under pion-dominated beam conditions. When combined with the Pb/SciFi calorimeter, the AstroPix layers successfully capture the development of electromagnetic showers. Using Cherenkov-based particle identification, electron-induced events exhibit significantly higher hit multiplicities and broader spatial distributions than pion-induced events, thereby providing clear discrimination between electromagnetic and hadronic showers. These results demonstrate that AstroPix-v3 provides effective, high-granularity imaging of shower development and is well suited as an imaging layer in future calorimeter systems for both collider and space-based experiments.

physics.ins-det

Beam test of a Pb/SciFi prototype for the Barrel Imaging Calorimeter at the Electron-Ion Collider

A Lead-Scintillating Fiber (Pb/SciFi) prototype for the Barrel Imaging Calorimeter (BIC) at the Electron--Ion Collider (EIC) was tested with electron beams at the CERN PS T10 beam line in August 2024. The prototype consisted of unit modules with a sampling structure of lead sheets and scintillating fibers, corresponding to a total depth of approximately $10.9\,X_{0}$. Beam tests were performed with electron momenta between 0.5 and 3~GeV/$c$ to evaluate the energy and timing performance of the prototype. This study characterizes the performance of a Pb/SciFi prototype and provides input for future beam tests, calibration and readout optimization, and the development of larger-scale prototypes.

physics.ins-det