Test-Beam Performance of the AstroPix Silicon Sensor for Imaging Calorimetry

Abstract

AstroPix is a high-voltage CMOS HVCMOS monolithic active pixel sensor MAPS developed for future space-based gamma-ray missions. It is also a candidate technology for the imaging layer of the Barrel Imaging Calorimeter BIC in the ePIC experiment at the future Electron-Ion Collider EIC. We report the first AstroPix test-beam results obtained at the KEK Photon Factory Advanced Ring PF-AR and the CERN Proton Synchrotron PS T10 beam line in 2025, using the third prototype AstroPix-v3. AstroPix-v3 sensors were operated as both standalone tracking layers and imaging layers interleaved with prototype lead/scintillating-fiber Pb/SciFi calorimeter modules, using electron and hadron beams in the few-GeV/c momentum range. Event synchronization between the continuous readout of AstroPix-v3 and the trigger-based readout of the Pb/SciFi calorimeter was achieved using a common timestamp. The AstroPix-v3 sensors exhibit stable performance, reaching a maximum hit efficiency of 68 percent at a bias voltage of -400 V under pion-dominated beam conditions. When combined with the Pb/SciFi calorimeter, the AstroPix layers successfully capture the development of electromagnetic showers. Using Cherenkov-based particle identification, electron-induced events exhibit significantly higher hit multiplicities and broader spatial distributions than pion-induced events, thereby providing clear discrimination between electromagnetic and hadronic showers. These results demonstrate that AstroPix-v3 provides effective, high-granularity imaging of shower development and is well suited as an imaging layer in future calorimeter systems for both collider and space-based experiments.

Explore related subjects

Keep this discovery

BibTeXRIS

Yoonha Hong, Jeongsu Bok, Geunpil An, Joonsuk Bae, Yunseul Bae, Regina Caputo, Yun Eo, Wooseok Ham, Woohyeon Heo, Manoj Jadhav, Seo Yun Jang, Jinryong Jeong, Hyon-Suk Jo, Sylvester Joosten, Beomkyu Kim, Bobae Kim, Chong Kim, Dongguk Kim, Minsuk Kim, Shin Hyung Kim, Woojong Kim, Wonjun Ko, Changhui Lee, Hyungjun Lee, Jason Sang Hun Lee, Jongwon Lee, Kyeongpil Lee, Sehwook Lee, Sangwoo Park, Jaehyeok Ryu, Bogyeong Seo, Jessica Metcalfe, Minsub Shim, Junseop Shin, Hwidong Yoo, Maria Żurek, Sanghoon Lim. 2026-05-08. Test-Beam Performance of the AstroPix Silicon Sensor for Imaging Calorimetry. https://arxiv.org/abs/2605.07681

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det