Searcharxiv⌕ Search

arXiv subjects

H. Kubo

Publications and source records attributed to H. Kubo.

At least 163 records · Page 9Linked to original sources

CANGAROO-III Observation of TeV Gamma Rays from the vicinity of PSR B1 706-44

Observation by the CANGAROO-III stereoscopic system of the Imaging Cherenkov Telescope has detected extended emission of TeV gamma rays in the vicinity of the pulsar PSR B1706$-$44. The strength of the signal observed as gamma-ray-like events varies when we apply different ways of emulating background events. The reason for such uncertainties is argued in relevance to gamma-rays embedded in the "off-source data", that is, unknown sources and diffuse emission in the Galactic plane, namely, the existence of a complex structure of TeV gamma-ray emission around PSR B1706$-$44.

astro-ph.HE↗

New Renormalization Scheme of Vacuum Polarization in QED

We examine the vacuum polarization contribution in the renormalization scheme of QED. Normally, the quadratic divergence term is discarded under the condition that the counter term of the Lagrangian density should be gauge invariant. Here, it is shown that the whole contribution of the photon self-energy should not be considered for the renormalization procedure. In fact, the finite contribution of the renormalization in the vacuum polarization is shown to give rise to the hyperfine splitting energy which disagrees with the experimental observation in hydrogen atom. For the treatment of the vacuum polarization, we present a new renormalization scheme of the photon self-energy diagram.

hep-th↗

Observation of Very High Energy Gamma Rays from HESS J1804-216 with CANGAROO-III Telescopes

We observed the unidentified TeV gamma-ray source HESS J1804-216 with the CANGAROO-III atmospheric Cerenkov telescopes from May to July in 2006. We detected very high energy gamma rays above 600 GeV at the 10 sigma level in an effective exposure of 76 hr. We obtained a differential flux of (5.0+/-1.5_{stat}+/-1.6_{sys})\times 10^{-12}(E/1 TeV)^{-α} cm^{-2}s^{-1}TeV^{-1} with a photon index αof 2.69 +/- 0.30_{stat} +/- 0.34_{sys}, which is consistent with that of the H.E.S.S. observation in 2004. We also confirm the extended morphology of the source. By combining our result with multi-wavelength observations, we discuss the possible counterparts of HESS J1804-216 and the radiation mechanism based on leptonic and hadronic processes for a supernova remnant and a pulsar wind nebula.

astro-ph↗

Monte-Carlo Simulator and Ancillary Response Generator of Suzaku XRT/XIS System for Spatially Extended Source Analysis

We have developed a framework for the Monte-Carlo simulation of the X-Ray Telescopes (XRT) and the X-ray Imaging Spectrometers (XIS) onboard Suzaku, mainly for the scientific analysis of spatially and spectroscopically complex celestial sources. A photon-by-photon instrumental simulator is built on the ANL platform, which has been successfully used in ASCA data analysis. The simulator has a modular structure, in which the XRT simulation is based on a ray-tracing library, while the XIS simulation utilizes a spectral "Redistribution Matrix File" (RMF), generated separately by other tools. Instrumental characteristics and calibration results, e.g., XRT geometry, reflectivity, mutual alignments, thermal shield transmission, build-up of the contamination on the XIS optical blocking filters (OBF), are incorporated as completely as possible. Most of this information is available in the form of the FITS (Flexible Image Transport System) files in the standard calibration database (CALDB). This simulator can also be utilized to generate an "Ancillary Response File" (ARF), which describes the XRT response and the amount of OBF contamination. The ARF is dependent on the spatial distribution of the celestial target and the photon accumulation region on the detector, as well as observing conditions such as the observation date and satellite attitude. We describe principles of the simulator and the ARF generator, and demonstrate their performance in comparison with in-flight data.

astro-ph↗

Development of Large area Gamma-ray Camera with GSO(Ce) Scintillator Arrays and PSPMTs

We have developed a position-sensitive scintillation camera with a large area absorber for use as an advanced Compton gamma-ray camera. At first we tested GSO(Ce) crystals. We compared light output from the GSO(Ce) crystals under various conditions: the method of surface polishing, the concentration of Ce, and co-doping Zr. As a result, we chose the GSO(Ce) crystals doped with only 0.5 mol% Ce, and its surface polished by chemical etching as the scintillator of our camera. We also made a 16$\times$16 cm$^2$ scintillation camera which consisted of 9 position-sensitive PMTs (PSPMTs Hamamatsu flat-panel H8500), the each of which had 8$\times$8 anodes with a pitch of 6 mm and coupled to 8$\times$8 arrays of pixelated 6$\times6\times$13 mm$^3$ GSO(Ce) scintillators. For the readout system of the 576 anodes of the PMTs, we used chained resistors to reduce the number of readout channels down to 48 to reduce power consumption. The camera has a position resolution of less than 6mm and a typical energy resolution of 10.5% (FWHM) at 662 keV at each pixel in a large area of 16$\times$16 cm$^2$. %to choose the best scintillator for our project. Furthermore we constructed a 16$\times$16 array of 3$\times3\times$13 mm$^3$ pixelated GSO(Ce) scintillators, and glued it to a PMT H8500. This camera had the position resolution of less than 3mm, over an area of 5$\times$5 cm$^2$, except for some of the edge pixels; the energy resolution was typically 13% (FWHM) at 662 keV.

astro-ph↗

Development of Gaseous Tracking Devices for the Search of WIMPs

The Time Projection Chamber (TPC) has been recognized as a potentially powerful detector for the search of WIMPs by measuring the directions of nuclear recoils, in which the most convincing signature of WIMPs, caused by the Earth's motion around the Galaxy, appears. We report on the first results of a performance study of the neutron exposure of our prototype micro-TPC with Ar-C$_2$H$_6$ (90:10) and CF$_4$ gas of 150 Torr.

astro-ph↗

Phase Separation in A-site Ordered Perovskite Manganite LaBaMn$_2$O$_6$ Probed by $^{139}$La and $^{55}$Mn NMR

$^{139}$La- and $^{55}$Mn-NMR spectra demonstrate that the ground state of the A-site ordered perovskite manganite LaBaMn$_2$O$_6$ is a spatial mixture of the ferromagnetic (FM) and antiferromagnetic (AFI(CE)) regions, which are assigned to the metallic and the insulating charge ordered state, respectively. This exotic coexisting state appears below 200 K via a first-order-like formation of the AFI(CE) state inside the FM one. Mn spin-spin relaxation rate indicates that the FM region coexisting with the AFI(CE) one in LaBaMn$_2$O$_6$ is identical to the bulk FM phase of the disordered form La$_{0.5}$Ba$_{0.5}$MnO$_3$ in spite of the absence of A-site disorder. This suggests mesoscopic rather than nanoscopic nature of FM region in LaBaMn$_2$O$_6$\@.

cond-mat.str-el↗

Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays

We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of $6\times6\times20{\rm mm}^3$ which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of $^{137}$Cs. We also investigated the energy resolution of these systems and showed the performance of the cascade connection of resistive network between some PMTs for large area detectors.

physics.ins-det↗

Development of an advanced Compton camera with gaseous TPC and scintillator

A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With the information of the recoil electrons and the scattered gamma-rays, this camera detects the energy and incident direction of each incident gamma-ray. We developed a prototype of the MeV gamma-ray camera with a micro-TPC and a NaI(Tl) scintillator, and succeeded in reconstructing the gamma-rays from 0.3 MeV to 1.3 MeV. Measured angular resolutions of ARM (Angular Resolution Measure) and SPD (Scatter Plane Deviation) for 356 keV gamma-rays were $18^\circ$ and $35^\circ$, respectively.

astro-ph↗

Development of an ASD IC for the Micro Pixel Chamber

A new amplifier-shaper-discriminator (ASD) chip was designed and manufactured for the Micro Pixel Chamber ($μ$-PIC). The design of this ASD IC is based on the ASD IC (TGC-ASD) for the Thin Gap Chamber in the LHC Atlas Experiment. The decay time constant of the preamplifier is 5-times longer than that of the TGC-ASD, and some other modifications have been made in order to improve the signal-to-noise ratio of the $μ$-PIC. The ASD IC uses SONY Analog Master Slice bipolar technology. The IC contains 4 channels in a QFP48 package. The decay time constant of the preamplifier is 80 ns and its gain is approximately 0.8 V/pC. The output from the preamplifier is received by a shaper (main-amplifier) with a gain of 7. A baseline restoration circuit is incorporated in the main-amplifier, and the current used for the baseline restoration is 5-times smaller than that of the TGC-ASD. The threshold voltage for the discriminator section is common to the 4 channels and their digital output level is LVDS-compatible. The ASD IC also has an analog output of the preamplifier. The equivalent noise charge at the input capacitance of 50 pF is around 2000 electrons. The power dissipation with LVDS outputs (100 $Ω$ load) is 57 mW/ch. Using this ASD, the analog output voltage from the signal of the $μ$-PIC is about 2-times higher than the case of using the TGC-ASD.As a consequence, the MIPs tracking performance of the Time Projection Chamber (TPC) with the $μ$-PIC was improved.The performance of the ASD IC and an improved tracking performance of the TPC are reported.

physics.ins-det↗

Development of a time projection chamber with micro pixel electrodes

A time projection chamber (TPC) based on a gaseous chamber with micro pixel electrodes (micro-PIC) has been developed for measuring three-dimensional tracks of charged particles. The micro-PIC with a detection area of 10 cm square consists of a double-sided printing circuit board. Anode pixels are formed with 0.4 mm pitch on strips aligned perpendicular to the cathode strips in order to obtain a two-dimensional position. In the TPC with drift length of 8 cm, 4 mm wide field cage electrodes are aligned at 1mm spaces and a uniform electric field of about 0.4 kV/cm is produced. For encoding of the three-dimensional position a synchronous readout system has been developed using Field Programmable Gate Arrays with 40 MHz clock. This system enables us to reconstruct the three-dimensional track of the particle at successive points like a cloud chamber even at high event rate. The drift velocity of electrons in the TPC was measured with the tracks of cosmic muons for three days, during which the TPC worked stably with the gas gain of 3000. With a radioisotope of gamma-ray source the three-dimensional track of a Compton scattered electron was taken successfully.

hep-ex↗

Performance of large area Micro Pixel Chamber

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536 pixel anodes of 400um pitch on a 100um thick insulating substrate. Achieved energy resolution was 30% (FWHM) at 5.9keV, and a gas gain of 7000 was obtained with argon ethane (8:2) gas mixture. This gain is high enough to detect minimum ionizing particles with such a small electrode pitch. Although several discharges occurred during 65 hours continuous operation, the detectors have kept stable operation with high gain. The micro-PIC is a useful detector for many applications e.g. X-ray, gamma ray, and charged particle imaging. The micro electrode structure allows us to measure directions of primary electrons due to incident X-rays or gamma rays, which provide a strong method for X-ray polarimetry and gamma-ray imaging.

hep-ex↗

Observation of gamma-rays greater than 10 TeV from Markarian 421

We have observed Markarian 421 in January and March 2001 with the CANGAROO-II imaging Cherenkov telescope during an extraordinarily high state at TeV energies. From 14 hours observations at very large zenith angles, $\sim70^\circ$, a signal of 298 $\pm$ 52 gamma-ray--like events (5.7 $σ$) was detected at $E>10$ TeV, where a higher sensitivity is achieved than those of usual observations near the zenith, owing to a greatly increased collecting area. Under the assumption of an intrinsic power-law spectrum, we derived a differential energy spectrum $dN/dE = (3.3 \pm 0.9_{stat.} \pm 0.3_{syst.})\times10^{-13} (E/10 {Te V})^{-(4.0 ^{+0.9}_{-0.6}_{stat.} \pm 0.3_{syst.})}$ ph./cm$^2$/sec/TeV, which is steeper than those previously measured around 1 TeV, and supports the evidence for a cutoff in the spectrum of Markarian 421. However, the 4 $σ$ excess at energies greater than 20 TeV in our data favors a cutoff energy of $\sim$8 TeV, at the upper end of the range previously reported from measurements at TeV energies.

astro-ph↗

The CANGAROO-III Project: Status report

We report on the status of the construction of an array of four 10 m atmospheric Cherenkov telescopes for gamma-ray astronomy, near Woomera, in South Australia -- the CANGAROO-III project. The first telescope of this array is the upgraded version of the CANGAROO-II 7 m telescope and has been in operation since March 2000. The second telescope, an improved version of the first, is being constructed for installation in late 2001. Stereoscopic observation of sub TeV gamma-rays with the two 10 m telescopes will begin in 2002 and the full array will be operational in 2004.

astro-ph↗

Search for gamma-rays above 10 TeV from Markarian 421 in a high state with the CANGAROO-II telescope

A preliminary result from Markarian 421 observations in the energy region above 10 TeV with the CANGAROO-II 10 m telescope is presented. In January 2001, the HEGRA group reported that Markarian 421 had become very active, with flux levels up to 4 times that of the Crab Nebula. As a result, we observed Mkn 421 during six nights from January 24th to February 1st, and four nights from March 1st to 4th. Observations were carried out using the very large zenith angle technique ($\sim$70 degree) and the energy threshold is estimated from Monte Carlo simulations to be around 10 TeV. We have detected gamma-ray emission in this energy range.

astro-ph↗

Complex Spectral Variability from Intensive Multi-wavelength Monitoring of Mrk421 in 1998

We conducted a multi-frequency campaign for the TeV blazar Mrk~421 in 1998 April. The campaign started from a pronounced high amplitude flare recorded by SAX and Whipple; ASCA observation started three days later. In the X-ray data, we detected multiple flares, occuring on time scales of about one day. ASCA data clearly reveal spectral variability. The comparison of the data from ASCA, EUVE and RXTE indicates that the variability amplitudes in the low energy synchrotron component are larger at higher photon energies. In TeV Gamma-rays, large intra-day variations -- which were correlated with the X-ray flux -- were observed when results from three Cherenkov telescopes are combined. The RMS variability of TeV Gamma--rays was similar to that observed in hard X-rays, above 10 keV. The X-ray light curve reveals flares which are almost symmetric for most of cases, implying the dominant time scale is the light crossing time through the emitting region. The structure function analysis based on the continuous X-ray light curve of seven days indicates that the characteristic time scale is ~0.5 day. The analysis of ASCA light curves in various energy bands appears to show both soft (positive) and hard (negative) lags. These may not be real, as systematic effects could also produce these lags, which are all much smaller than an orbit. If the lags of both signs are real, these imply that the particle acceleration and X-ray cooling time scales are similar.

astro-ph↗

Evidence of thick obscuring matter revealed in the X-ray spectrum of the Z=4.28 quasar RXJ1028.6-0844

We report the discovery of an unambiguous, substantial low-energy cutoff in the broad band X-ray spectrum of the radio quasar RXJ1028.6-0844 at a redshift of 4.276 obtained with the ASCA satellite, which we preferably explained as indication of excess X-ray absorption. The equivalent hydrogen column density of the absorbing matter, depending on the redshift and metallicity, ranges from 2.5x10**21 cm**(-2) for local absorption up to 2.1x10**23 cm**(-2) (solar metallicity) or 1.6x10**24 cm**(-2) (10% solar metallicity) for absorption at the quasar redshift. Such a value is among the largest found for high-redshift radio quasars. The absorption, if interpreted as being produced close to the quasar, may indicate the presence of a remarkably large amount of obscuring matter in the quasar environment in the early universe. Implications of the result for the possible origins of the absorbing matter are discussed, concerning especially galactic intervening matter, cool intracluster gas, and ambient medium around the quasar jet. The quasar itself has an enormous apparent luminosity of at least about 2.6x10**47 erg/s (H0=50, q0=0.5) and a power law photon index of 1.67(+0.07,-0.04) in the 2-50keV band in the source rest frame.

astro-ph↗

The optical reflector system for the CANGAROO-II imaging atmospheric Cherenkov telescope

A new imaging atmospheric Cherenkov telescope (CANGAROO-II) with a light-weight reflector has been constructed. Light, robust, and durable mirror facets of containing CFRP (Carbon Fiber Reinforced Plastic) laminates were developed for the telescope. The attitude of each facet can be adjusted by stepping motors. In this paper, we describe the design, manufacturing, alignment procedure, and the performance of the CANGAROO-II optical reflector system.

astro-ph↗