SearcharxivSearch

arXiv subjects

H. S. Miley

Publications and source records attributed to H. S. Miley.

At least 19 recordsLinked to original sources

The MAJORANA DEMONSTRATOR experiment's construction, commissioning, and performance

Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to justify building a tonne-scale experiment to search for the neutrinoless double-beta decay ($ββ(0ν)$) of $^{76}\mathrm{Ge}$. Purpose: This paper presents a description of the instrument, its commissioning, and operations. It covers the electroforming, underground infrastructure, enrichment, detector fabrication, low-background and construction techniques, electronics, data acquisition, databases, and data processing of the MAJORANA DEMONSTRATOR. Method: The MAJORANA DEMONSTRATOR operated inside an ultra-low radioactivity passive shield at the 4850-foot~level of the Sanford Underground Research Facility (SURF) from 2015-2021. Results and Conclusions: The MAJORANA DEMONSTRATOR achieved the best energy resolution and second-best background level of any $ββ(0ν)$ search. This enabled it to achieve an ultimate half-life limit on $ββ(0ν)$ in $^{76}\mathrm{Ge}$ of $8.3\times 10^{25}$~yr (90\% C.L.) and perform a rich set of searches for other physics beyond the Standard Model.

physics.ins-det

Search for Zero-Neutrino Double Beta Decay in 76Ge with the Majorana Demonstrator

The \MJ\ Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\ comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. We achieve unprecedented energy resolution of 2.5 keV FWHM at \qval\ and a very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, resulting in a lower limit on the half-life of $1.9\times10^{25}$ yr (90\% CL). This result constrains the effective Majorana neutrino mass to below 240 to 520 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is $4.0_{-2.5}^{+3.1}$ counts/(FWHM t yr).

nucl-ex

Development of a low-level Ar-37 calibration standard

Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level Ar-37 standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in developing a process to generate and quantify low-level Ar-37 standards, which can be used to calibrate sensitive field systems at activities consistent with soil background levels. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.

physics.ins-det

Maximum Likelihood Signal Extraction Method Applied to 3.4 years of CoGeNT Data

CoGeNT has taken data for over 3 years, with 1136 live days of data accumulated as of April 23, 2013. We report on the results of a maximum likelihood analysis to extract any possible dark matter signal present in the collected data. The maximum likelihood signal extraction uses 2-dimensional probability density functions (PDFs) to characterize the anticipated variations in dark matter interaction rates for given observable nuclear recoil energies during differing periods of the Earth's annual orbit around the Sun. Cosmogenic and primordial radioactivity backgrounds are characterized by their energy signatures and in some cases decay half-lives. A third parameterizing variable -- pulse rise-time -- is added to the likelihood analysis to characterize slow rising pulses described in prior analyses. The contribution to each event category is analyzed for various dark matter signal hypotheses including a dark matter standard halo model and a case with free oscillation parameters (i.e., amplitude, period, and phase). The best-fit dark matter signal is in close proximity to previously reported results. We find that the significance of the extracted dark matter signal remains well below evidentiary at 1.7 $σ$.

astro-ph.CO

Search for An Annual Modulation in Three Years of CoGeNT Dark Matter Detector Data

Weakly Interacting Massive Particles (WIMPs) are well-established dark matter candidates. WIMP interactions with sensitive detectors are expected to display a characteristic annual modulation in rate. We release a dataset spanning 3.4 years of operation from a low-background germanium detector, designed to search for this signature. A previously reported modulation persists, concentrated in a region of the energy spectrum populated by an exponential excess of unknown origin. Its phase and period agree with phenomenological expectations, but its amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP galactic halo. We consider the possibility of a non-Maxwellian local halo velocity distribution as a plausible explanation, able to help reconcile recently reported WIMP search anomalies.

astro-ph.CO

CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors

CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instrumental stability, data analysis, and background estimation. A detailed background model is used to investigate the low energy excess of events previously reported, and to assess the possibility of temporal modulations in the low-energy event rate. Extensive simulations of all presently known backgrounds do not provide a viable background explanation for the excess of low-energy events in the CoGeNT data, or the previously observed temporal variation in the event rate. Also reported on for the first time is a determination of the surface (slow pulse rise time) event contamination in the data as a function of energy. We conclude that the CoGeNT detector technology is well suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA results

astro-ph.CO

Final Analysis and Results of the Phase II SIMPLE Dark Matter Search

We report the final results of the Phase II SIMPLE measurements, comprising two run stages of 15 superheated droplet detectors each, the second stage including an improved neutron shielding. The analyses includes a refined signal analysis, and revised nucleation efficiency based on reanalysis of previously-reported monochromatic neutron irradiations. The combined results yield a contour minimum of σ_{p} = 4.2 x 10^-3 pb at 35 GeV/c^2 on the spin-dependent sector of WIMP-proton interactions, the most restrictive to date from a direct search experiment and overlapping for the first time results previously obtained only indirectly. In the spin-independent sector, a minimum of 3.6 x 10^-6 pb at 35 GeV/c^2 is achieved, with the exclusion contour challenging the recent CoGeNT region of current interest.

astro-ph.CO

Search for an Annual Modulation in a P-type Point Contact Germanium Dark Matter Detector

Fifteen months of cumulative CoGeNT data are examined for indications of an annual modulation, a predicted signature of Weakly Interacting Massive Particle (WIMP) interactions. Presently available data support the presence of a modulated component of unknown origin, with parameters prima facie compatible with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield a statistical significance for a modulation of ~2.8 sigma, limited by the short exposure.

astro-ph.CO

First Results of the Phase II SIMPLE Dark Matter Search

We report results of a 14.1 kgd measurement with 15 superheated droplet detectors of total active mass 0.208 kg, comprising the first stage of a 30 kgd Phase II experiment. In combination with the results of the neutron-spin sensitive XENON10 experiment, these results yield a limit of |a_p| < 0.32 for M_W = 50 GeV/c2 on the spin-dependent sector of weakly interacting massive particle-nucleus interactions with a 50% reduction in the previously allowed region of the phase space formerly defined by XENON, KIMS and PICASSO. In the spin-independent sector, a limit of 2.3x10-5 pb at M_W = 45 GeV/c2 is obtained.

astro-ph.CO

Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector

The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c^2 mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the MAJORANA Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.

nucl-ex

Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector

We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to the DAMA/LIBRA annual modulation effect, the hint of a signal in CDMS, and phenomenological predictions. Improved constraints are placed on a cosmological origin for the DAMA/LIBRA effect.

astro-ph.CO

A CF3I-based SDD Prototype for Spin-independent Dark Matter Searches

The application of Superheated Droplet Detectors (SDDs) to dark matter searches has so far been confined to the light nuclei refrigerants C2ClF5 and C4F10 (SIMPLE and PICASSO, respectively), with a principle sensitivity to spin-dependent interactions. Given the competitive results of these devices, as a result of their intrinsic insensitivity to backgrounds, we have developed a prototype trifluoroiodomethane (CF3I)-loaded SDD with increased sensitivity to spin-independent interactions as well. A low (0.102 kgd) exposure test operation of two high concentration, 1 liter devices is described, and the results compared with leading experiments in both spin-dependent and -independent sectors. Although competitive in both sectors when the difference in exposures is accounted for, a problem with fracturing of the detector gel must be addressed before significantly larger exposures can be envisioned.

astro-ph

Experimental constraints on a dark matter origin for the DAMA annual modulation effect

A claim for evidence of dark matter interactions in the DAMA experiment has been recently reinforced. We employ a new type of germanium detector to conclusively rule out a standard isothermal galactic halo of Weakly Interacting Massive Particles (WIMPs) as the explanation for the annual modulation effect leading to the claim. Bounds are similarly imposed on a suggestion that dark pseudoscalars mightlead to the effect. We describe the sensitivity to light dark matter particles achievable with our device, in particular to Next-to-Minimal Supersymmetric Model candidates.

astro-ph

Real-time digital signal processor implementation of self-calibrating pulse-shape discriminator for high purity germanium

Pulse-shape analysis of the ionization signals from germanium gamma-ray spectrometers is a method for obtaining information that can characterize an event beyond just the total energy deposited in the crystal. However, as typically employed, this method is data-intensive requiring the digitization, transfer, and recording of electronic signals from the spectrometer. A hardware realization of a real-time digital signal processor for implementing a parametric pulse shape is presented. Specifically, a previously developed method for distinguishing between single-site and multi-site gamma-ray interactions is demonstrated in an on-line digital signal processor, compared with the original off-line pulse-shape analysis routine, and shown to have no significant difference. Reduction of the amount of the recorded information per event is shown to translate into higher duty-cycle data acquisition rates while retaining the benefits of additional event characterization from pulse-shape analysis.

nucl-ex

SIMPLE Dark Matter Search Results

We report an improved SIMPLE experiment comprising four superheated droplet detectors with a total exposure of 0.42 kgd. The result yields ~ factor 10 improvement in the previously-reported results, and -- despite the low exposure -- is seen to provide restrictions on the allowed phase space of spin-dependent coupling strengths almost equivalent to those from the significantly larger exposure NAIADCDMS/ZEPLIN searches.

hep-ex

Pulse Shape Discrimination in the IGEX Experiment

The IGEX experiment has been operating enriched germanium detectors in the Canfranc Underground Laboratory (Spain) in a search for the neutrinoless double decay of 76Ge. The implementation of Pulse Shape Discrimination techniques to reduce the radioactive background is described in detail. This analysis has been applied to a fraction of the IGEX data, leading to a rejection of ~60 % of their background, in the region of interest (from 2 to 2.5 MeV), down to ~0.09 c/(keV kg y).

hep-ex

Status of IGEX dark matter search at Canfranc Underground Laboratory

One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. In this talk we report on the on-going efforts to understand and eventually reject the background at low energy. These efforts have led to the improvement of the neutron shielding and to partial reduction of the background, but still the remaining events are not totally identified. A tritium contamination or muon-induced neutrons are considered as possible sources, simulations and experimental test being still under progress. According to the success of this study we comment the prospects of the experiment as well as those of its future extension, the GEDEON dark matter experiment.

astro-ph

Comment on "Evidence for Neutrinoless Double Beta Decay"

We comment on the recent claim for the experimental observation of neutrinoless double-beta decay. We discuss several limitations in the analysis provided in that paper and conclude that there is no basis for the presented claim.

hep-ex