arXiv · hep-ex/0302018
Pulse Shape Discrimination in the IGEX Experiment
Abstract
The IGEX experiment has been operating enriched germanium detectors in the Canfranc Underground Laboratory (Spain) in a search for the neutrinoless double decay of 76Ge. The implementation of Pulse Shape Discrimination techniques to reduce the radioactive background is described in detail. This analysis has been applied to a fraction of the IGEX data, leading to a rejection of ~60 % of their background, in the region of interest (from 2 to 2.5 MeV), down to ~0.09 c/(keV kg y).
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
D. Gonzalez, J. Morales, S. Cebrian, E. Garcia, I. G. Irastorza, A. Morales, A. Ortiz de Solorzano, J. Puimedon, M. L. Sarsa, J. A. Villar, C. E. Aalseth, F. T. Avignone III, R. L. Brodzinski, W. K. Hensley, H. S. Miley, J. H. Reeves, I. V. Kirpichnikov, A. A. Klimenko, S. B. Osetrov, A. A. Smolnikov, A. A. Vasenko, S. I. Vasiliev, V. S. Pogosov, A. G. Tamanyan. 2003-02-14. Pulse Shape Discrimination in the IGEX Experiment. https://doi.org/10.1016/j.nima.2003.06.008
Cite the original work for its findings. Save a collection to share your selection of sources.