Searcharxiv⌕ Search

arXiv subjects

Hans-Werner Fink

Publications and source records attributed to Hans-Werner Fink.

At least 37 records · Page 2Linked to original sources

A quantum mechanical scheme to reduce radiation damage in electron microscopy

We show that radiation damage to unstained biological specimens is not an intractable problem in electron microscopy. When a structural hypothesis of a specimen is available, quantum mechanical principles allow us to verify the hypothesis with a very low electron dose. Realization of such a concept requires precise control of the electron wave front. Based on a diffractive electron optical implementation, we demonstrate the feasibility of this new method by both experimental and numerical investigations.

quant-ph↗

Reconstruction of purely absorbing, absorbing and phase-shifting, and strong phase-shifting objects from their single-shot in-line holograms

We address the problem of reconstructing phase-shifting objects from their single shot in-line holograms. We show that a phase-shifting object cannot be reliably recovered from its in-line hologram by non-iterative reconstruction routines, and that an iterative reconstruction should be applied. We demonstrate examples of simulated in-line holograms of objects with the following properties: purely absorbing, both absorbing and phase shifting, and strong phase-shifting. We investigate the effects of noise and interference contrast in holograms on the reconstruction results and discuss details of an optimal iterative procedure to quantitatively recover the correct absorbing and phase-shifting properties of the object. We also review previously published reconstructions of experimental holograms and summarize the optimal parameters for retrieval of phase-shifting objects from their in-line holograms.

physics.optics↗

Design and Implementation of a Micron-Sized Electron Column Fabricated by Focused Ion Beam Milling

We have designed, fabricated and tested a micron-sized electron column with an overall length of about 700 microns comprising two electron lenses; a micro-lens with a minimal bore of 1 micron followed by a second lens with a bore of up to 50 microns in diameter to shape a coherent low-energy electron wave front. The design criteria follow the notion of scaling down source size, lens-dimensions and kinetic electron energy for minimizing spherical aberrations to ensure a parallel coherent electron wave front. All lens apertures have been milled employing a focused ion beam and could thus be precisely aligned within a tolerance of about 300 nm from the optical axis. Experimentally, the final column shapes a quasi-planar wave front with a minimal full divergence angle of 4 mrad and electron energies as low as 100 eV.

physics.ins-det↗

Holography and Coherent Diffraction with Low-Energy Electrons: A Route towards Structural Biology at the Single Molecule Level

The current state of the art in structural biology is led by NMR, X-ray crystallography and TEM investigations. These powerful tools however all rely on averaging over a large ensemble of molecules. Here, we present an alternative concept aiming at structural analysis at the single molecule level. We show that by combining electron holography and coherent diffraction imaging estimations concerning the phase of the scattered wave become needless as the phase information is extracted from the data directly and unambiguously. Performed with low-energy electrons the resolution of this lens-less microscope is just limited by the De Broglie wavelength of the electron wave and the numerical aperture, given by detector geometry. In imaging freestanding graphene, a resolution of 2 Angstrom has been achieved revealing the 660.000 unit cells of the graphene sheet from one data set at once. Applied to individual biomolecules the method allows for non-destructive imaging and imports the potential to distinguish between different conformations of proteins with atomic resolution.

physics.atm-clus↗

Atomically resolved structural determination of graphene and its point defects via extrapolation assisted phase retrieval

Previously reported crystalline structures obtained by an iterative phase retrieval reconstruction of their diffraction patterns seem to be free from displaying any irregularities or defects in the lattice, which appears to be unrealistic. We demonstrate here that the structure of a nanocrystal including its atomic defects can unambiguously be recovered from its diffraction pattern alone by applying a direct phase retrieval procedure not relying on prior information of the object shape. Individual point defects in the atomic lattice are clearly apparent. Conventional phase retrieval routines assume isotropic scattering. We show that when dealing with electrons, the quantitatively correct transmission function of the sample cannot be retrieved due to anisotropic, strong forward scattering specific to electrons. We summarize the conditions for this phase retrieval method and show that the diffraction pattern can be extrapolated beyond the original record to even reveal formerly not visible Bragg peaks. Such extrapolated wave field pattern leads to enhanced spatial resolution in the reconstruction.

cond-mat.mtrl-sci↗

Interfacing Ultraclean Graphene with Solid-State Devices

Interfacing graphene with solid-state devices and maintaining it free of contamination is a crucial step towards a functioning device, be it a semiconductor structure or any other device for technological applications. We take advantage of the catalytic properties of platinum metals to completely remove the polymer capping after the transfer of macroscopic graphene sheets to a solid-state device. For that purpose a platinum metal coated structure is brought in close proximity with the polymer capping. Subsequent annealing in air at a temperature between 175 and 350°C actuates a complete catalytic removal of the polymer. Finally, the platinum metal catalyst is removed revealing ultra clean graphene interfaced with an arbitrary device. Experiments to interface macroscopic graphene layers with oxidized silicon wafers demonstrate the general applicability of this approach. In repeating the procedure, multi-layer graphene sheets can also be produced. Direct evidence for the latter is provided by optical images of three overlapping graphene sheets. The exceeding level of cleanliness of the graphene is examined on the nanometer scale by means of low-energy electron transmission microscopy.

cond-mat.mes-hall↗

Low-energy electron holographic imaging of gold nanorods supported by ultraclean graphene

An ideal support for electron microscopy shall be as thin as possible and interact as little as possible with the primary electrons. Since graphene is atomically thin and made up of carbon atoms arranged in a honeycomb lattice, the potential to use graphene as substrate in electron microscopy is enormous. Until now graphene has hardly ever been used for this purpose because the cleanliness of freestanding graphene before or after deposition of the objects of interest was insufficient. We demonstrate here by means of low-energy electron holographic imaging that freestanding graphene prepared with the Platinum-metal catalysis method remains ultraclean even after re-exposure to ambient conditions and deposition of gold-nanorods from the liquid phase. In the holographic reconstruction of the gold particles the organic shell surrounding the objects is imaged while it is not detectable in SEM images of the very same sample, demonstrating the tremendous potential of low-energy electron holography for the imaging of graphene-supported single biomolecules.

cond-mat.mtrl-sci↗

Coherent microscopy at resolution beyond diffraction limit using post-experimental data extrapolation

Conventional microscopic records represent intensity distributions whereby local sample information is mapped onto local information at the detector. In coherent microscopy, the superposition principle of waves holds; field amplitudes are added, not intensities. This non-local representation is spread out in space and interference information combined with wave continuity allows extrapolation beyond the actual detected data. Established resolution criteria are thus circumvented and hidden object details can retrospectively be recovered from just a fraction of an interference pattern.

physics.optics↗

On artefact-free reconstruction of low-energy (30-250 eV) electron holograms

Low-energy electrons (30-250 eV) have been successfully employed for imaging individual biomolecules. The most simple and elegant design of a low-energy electron microscope for imaging biomolecules is a lensless setup that operates in the holographic mode. In this work we address the problem associated with the reconstruction from the recorded holograms. We discuss the twin image problem intrinsic to inline holography and the problem of the so-called biprism-like effect specific to low-energy electrons. We demonstrate how the presence of the biprism-like effect can be efficiently identified and circumvented. The presented sideband filtering reconstruction method eliminates the twin image and allows for reconstruction despite the biprism-like effect, which we demonstrate on both, simulated and experimental examples.

physics.ins-det↗

Pulsed Electron Holography

A technique of pulsed low-energy electron holography is introduced that allows for recording highly resolved holograms within reduced exposure times. Therefore, stacks of holograms are accumulated in a pulsed mode with individual acquisition times as short as 50 μs. Subsequently, these holograms are aligned and finally superimposed. The resulting holographic record reveals previously latent high-order interference fringes and thereby pushing interference resolution into the sub-nanometer regime. In view of the non-damaging character of low-energy electrons, the method is of particular interest for structural analysis of fragile biomolecules.

physics.ins-det↗

Coherent diffraction and holographic imaging of individual biomolecules using low-energy electrons

Modern microscopy techniques are aimed at imaging an individual molecule at atomic resolution. Here we show that low-energy electrons with kinetic energies of 50-250 eV offer a possibility of overcome the problem of radiation damage, and obtaining images of individual biomolecules. Two experimental schemes for obtaining images of individual molecules, holography and coherent diffraction imaging, are discussed and compared. Images of individual molecules obtained by both techniques, using low-energy electrons, are shown.

physics.bio-ph↗

Graphene Unit Cell Imaging by Holographic Coherent Diffraction

We have imaged a freestanding graphene sheet of 210 nm in diameter with 2 Angstrom resolution by combining coherent diffraction and holography with low-energy electrons. The entire sheet is reconstructed from just a single diffraction pattern displaying the arrangement of 660.000 individual graphene unit cells at once. Given the fact that electrons with kinetic energies of the order of 100 eV do not damage biological molecules, it will now be a matter to develop methods for depositing individual proteins onto such graphene sheets.

cond-mat.mtrl-sci↗

When holography meets coherent diffraction imaging

Modern imaging techniques at the molecular scale rely on utilizing novel coherent light sources like X-ray free electron lasers for the ultimate goal of visualizing such objects as individual biomolecules rather than crystals. Here, unlike in the case of crystals where structures can be solved by model building and phase refinement, the phase distribution of the wave scattered by an individual molecule must directly be recovered. There are two well-known solutions to the phase problem: holography and coherent diffraction imaging (CDI). Both techniques have their pros and cons. In holography, the reconstruction of the scattered complex-valued object wave is directly provided by a well-defined reference wave that must cover the entire detector area which often is an experimental challenge. CDI provides the highest possible, only wavelength limited, resolution, but the phase recovery is an iterative process which requires some pre-defined information about the object and whose outcome is not always uniquely-defined. Moreover, the diffraction patterns must be recorded under oversampling conditions, a pre-requisite to be able to solve the phase problem. Here, we report how holography and CDI can be merged into one superior technique: holographic coherent diffraction imaging (HCDI). An inline hologram can be recorded by employing a modified CDI experimental scheme. We demonstrate that the amplitude of the Fourier transform of an inline hologram is related to the complex-valued visibility, thus providing information on both, the amplitude and the phase of the scattered wave in the plane of the diffraction pattern. With the phase information available, the condition of oversampling the diffraction patterns can be relaxed, and the phase problem can be solved in a fast and unambiguous manner.

physics.optics↗

Ultra-Clean Freestanding Graphene by Platinum-Metal Catalysis

While freestanding clean graphene is essential for various applications, existing technologies for removing the polymer layer after transfer of graphene to the desired substrate still leave significant contaminations behind. We discovered a method for preparing ultra-clean freestanding graphene utilizing the catalytic properties of platinum metals. Complete catalytic removal of polymer residues requires annealing in air at a temperature between 175 and 350°C. Low-energy electron holography investigations prove that this method results in ultra-clean freestanding graphene.

cond-mat.mtrl-sci↗

Low-energy electron transmission imaging of clusters on free-standing graphene

We investigated the utility of free-standing graphene as a transparent sample carrier for imaging nanometer-sized objects by means of low-energy electron holography. The sample preparation for obtaining contamination-free graphene as well as the experimental setup and findings are discussed. For incoming electrons with 66 eV kinetic energy graphene exhibits 27% opacity per layer. Hence, electron holograms of nanometer-sized objects adsorbed on free-standing graphene can be recorded and numerically reconstructed to reveal the object's shapes and distribution. Furthermore, a Moire effect has been observed with free-standing graphene multi-layers.

cond-mat.mes-hall↗

Non-destructive imaging of an individual protein

The mode of action of proteins is to a large extent given by their ability to adopt different conformations. This is why imaging single biomolecules at atomic resolution is one of the ultimate goals of biophysics and structural biology. The existing protein database has emerged from X-ray crystallography, NMR or cryo-TEM investigations. However, these tools all require averaging over a large number of proteins and thus over different conformations. This of course results in the loss of structural information. Likewise it has been shown that even the emergent X-FEL technique will not get away without averaging over a large quantity of molecules. Here we report the first recordings of a protein at sub-nanometer resolution obtained from one individual ferritin by means of low-energy electron holography. One single protein could be imaged for an extended period of time without any sign of radiation damage. Since ferritin exhibits an iron core, the holographic reconstructions could also be cross-validated against TEM images of the very same molecule by imaging the iron cluster inside the molecule while the protein shell is decomposed.

physics.bio-ph↗

Novel Fourier-domain constraint for fast phase retrieval in coherent diffraction imaging

Coherent diffraction imaging (CDI) for visualizing objects at atomic resolution has been realized as a promising tool for imaging single molecules. Drawbacks of CDI are associated with the difficulty of the numerical phase retrieval from experimental diffraction patterns; a fact which stimulated search for better numerical methods and alternative experimental techniques. Common phase retrieval methods are based on iterative procedures which propagate the complex-valued wave between object and detector plane. Constraints in both, the object and the detector plane are applied. While the constraint in the detector plane employed in most phase retrieval methods requires the amplitude of the complex wave to be equal to the squared root of the measured intensity, we propose a novel Fourier-domain constraint, based on an analogy to holography. Our method allows achieving a low-resolution reconstruction already in the first step followed by a high-resolution reconstruction after further steps. In comparison to conventional schemes this Fourier-domain constraint results in a fast and reliable convergence of the iterative reconstruction process.

physics.optics↗

Non-destructive Imaging of Individual Bio-Molecules

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

physics.bio-ph↗