SearcharxivSearch

arXiv subjects

Hong-Bang Liu

Publications and source records attributed to Hong-Bang Liu.

14 recordsLinked to original sources

Synchrotron polarization of anisotropic electron distribution in GRB prompt emission

In gamma-ray bursts (GRBs), the electron pitch angle ($α$) is usually assumed to be isotropically distributed. However, recent numerical simulations indicate that only the high-energy electrons (with Lorentz factors $γ>γ_{iso}$) are distributed isotropically, whereas the low-energy electrons (with $γ<γ_{iso}$) follow an energy-dependent anisotropic distribution during magnetic reconnection. The mean value of $\sin^2 α$ approximately follows the relation $\langle \sin^2 α\rangle \propto γ^{m}$ for $γ<γ_{iso}$. In principle, polarization measurements may help us constrain the pitch-angle distribution of electrons in GRBs, since different pitch-angle distributions produce distinct synchrotron polarization signatures. The polarization of GRBs produced by isotropically distributed electrons has been extensively studied. In this paper, we investigate synchrotron polarization produced by anisotropically distributed electrons within a globally toroidal magnetic field in GRB prompt emission. Our results show that the synchrotron PDs in the $γ$-ray and X-ray bands produced by anisotropically distributed electrons are systematically lower than those produced by isotropically distributed electrons, while the PD in the optical band could be either lower or higher than that of isotropically distributed electrons, depending primarily on the value of the energy slope $m$. In addition, we compared our numerical results with observational data, and the comparison suggests that an anisotropic distribution of electrons may offer a potential explanation for the PD and spectral data of some GRBs.

astro-ph.HE

Design and preliminary performance study of the broad-band spectrometer detector for POLAR-2

POLAR-2, the successor of the POLAR experiment aboard China's Tiangong-2 space lab, is set to be deployed on the China Space Station. The POLAR-2 mission aims to conducting high-precision polarization measurements of high-energy transients with a primary focus on Gamma-Ray Bursts (GRBs), following POLAR's pioneering accurate polarization measurements of GRB prompt emission. One of the key advancements in POLAR-2 is the inclusion of a dedicated Broad-band Spectrometer Detector (BSD) instrument, designed to provide precise measurements of GRB location and spectral parameters, which are critical inputs for accurate polarization analysis of POLAR-2's dedicated High-energy Polarimetry Detector (HPD), which is made of plastic scintillator bars array. BSD employs a coded-aperture mask imaging technique and pixelated GAGG scintillation crystals, offering a wide half-coded field of view of ~132° x 125° and an operational energy range of 10-1000 keV. Simulation results indicate that the instrument can achieve a localization accuracy of approximately 1.5° for faint GRBs similar to GRB 170817A, satisfying the core requirements of GRB polarimetry with HPD. BSD also has moderate capability for GRB polarimetry, particularly at several hundred keV energy. This paper outlines the preliminary design of BSD and presents an overall evaluation of its expected scientific performance, based on extensive Monte Carlo simulations and preliminary ground-based calibration tests.

astro-ph.IM

Topmetal-L: A Low Noise Charge-Sensitive Pixel Sensor for POLAR2/LPD

POLAR-2 is a next-generation space astronomy platform led by China, with its core scientific objective focused on high-precision polarization measurements of gamma-ray bursts. As one of its key payloads, the Low-energy Polarization Detector (LPD) is designed to perform wide-field surveys to capture X-ray polarization information from gamma-ray bursts in the 2$\sim$10 keV energy range. This paper presents Topmetal-L, a dedicated charge-sensitive pixel sensor developed for the LPD prototype upgrade. Fabricated in a 130 nm CMOS process in 2024, the chip integrates a 356 $\times$ 512 pixel array with a pixel pitch of 45 $μ$m. Each pixel incorporates a 26 $\times$ 26 $μ$m$^2$ charge-collecting window and is capable of simultaneously outputting both energy and position information of deposited charges. Topmetal-L has been systematically optimized for power consumption, noise performance, and readout efficiency. It exhibits an input dynamic range of 0$\sim$4 ke$^{-}$, a typical charge-to-voltage conversion gain of 76.04 $μ$V/e$^{-}$, an average equivalent noise charge of approximately 22.8 e$^{-}$, a sensitive area exceeding 3.69 cm$^2$, and a total power consumption of 720 mW per chip. To meet the requirements of large-area, high-frame-rate readout for gas-based polarization detectors, a sentinel readout scheme is proposed, reducing the full-frame readout time to 730 $μ$s. A prototype Topmetal-L-based gas polarization detection system was evaluated across key energies: it exhibited a residual modulation of 0.26% $\pm$ 0.45% at 5.90 keV, a modulation factor of 66.67% $\pm$ 0.45% for a linearly polarized 8.05 keV source, and a count rate saturated at 15 k counts$\cdot$cm$^{-2}$$\cdot$s$^{-1}$ when tested at 5.40 keV.

astro-ph.IM

A Novel Pixel-Chip-Based Region-of-Interest Readout Circuit Design

This paper presents a novel pixel chip readout scheme: the Region-of-Interest Readout Circuit (ROIRC), which is designed for large area, large array pixel chips and Gas Pixel Detector (GPD). This design employs a sentinel pixel detection strategy, enabling rapid identification and prioritized readout of the pixel regions containing signal events. During the scanning readout of these signal events, ROIRC employs a Block-based readout approach, effectively minimizing the readout of non-signal pixels. The functionality of ROIRC has been successfully implemented on both the ASIC and FPGA platforms. In the tests of the ROIRC, the pixel chip embedded in the GPD is capable of detecting low-energy X-rays in the range of 2-10 keV and supports multiple event readouts, and the pixel chip can read out photo-electron signal events with the count rate up to 15k / (cm2 x s).

physics.ins-det

In-orbit background and sky survey simulation study of POLAR-2/LPD

The Low-Energy X-ray Polarization Detector (LPD) is one of the payloads in the POLAR-2 experiment, designed as an external payload for the China Space Station (CSS) deployment in early 2024. LPD is specifically designed to observe the polarization of Gamma-Ray Bursts (GRBs) prompt emission in the energy range of 2-10 keV, with a wide field of view (FoV) of 90 degrees in preliminary design. This observation is achieved using an array of X-ray photoelectric polarimeters based on gas pixel detectors. Due to the wide FoV configuration, the in-orbit background count rate in the soft X-ray range is high, while GRBs themselves also exhibit a high flux in this energy band. In order to assess the contribution of various background components to the total count rate, we conducted detailed simulations using the GEANT4 C++ package. Our simulations encompassed the main interactions within the instrument materials and provided insights into various background components within the wide FoV scheme. The simulation results reveal that among the background components, the primary contributors are the cosmic X-ray background (CXB) and bright X-ray sources. The total background count rate of LPD, after applying the charged particle background rejection algorithm, is approximately 0.55 counts/cm^2/s on average, and it varies with the detector's orbit and pointing direction. Furthermore, we performed comprehensive simulations and comparative analyses of the CXB and X-ray bright sources under different FoVs and detector pointings. These analyses provide valuable insights into the background characteristic for soft X-ray polarimeter with wide FoV.

astro-ph.IM

Wide-Field X-ray Polarimetry for High Energy Astronomical Transients: First results of the pathfinder CXPD Cubesat Mission

The Low Energy Polarization Detector (LPD) is a key component of the next-generation large-scale Gamma-Ray Burst polarimeter, POLAR-2. It is designed for polarization observations of transient sources in the soft X-ray energy range with a wide field of view (FOV). To validate the key technologies required for wide-FOV X-ray polarization measurements, the Cosmic X-ray Polarization Detector (CXPD) CubeSat was developed as a prototype for the LPD. The CXPD is equipped with two Gas Microchannel Plate Pixel Detectors (GMPDs) that measure X-ray polarization via the photoelectric effect, where ejected photoelectrons produce ionization tracks in the gas which are imaged to reconstruct their emission directions. Laboratory calibrations of the modulation factor and energy spectra were successfully performed using linear polarized X-ray sources at 2.98 keV, 4.51 keV, 6.40 keV, and 8.05 keV. Since its launch in June 2023, the CXPD has successfully completed critical in-orbit technology verification. It has also performed polarization observations of two bright X-ray sources Sco X-1 and the transient Swift J1727.8-1613 yielding constraints on their polarization degrees and angles. Notably, this was the first time that an anti-coincidence detector had been implemented in an X-ray polarimeter, enabling in-orbit verification of the charged-particle background rejection algorithm. These results demonstrate the feasibility of wide-field soft X-ray polarization measurements and provide essential guidance for the development of the LPD for the POLAR-2 mission, thereby advancing the frontier of X-ray polarization astronomy.

astro-ph.IM

Polarization degree of magnetic field structure changes caused by random magnetic field in Gamma-ray Burst

In a Poynting-flux-dominated (PFD) jet that exhibits an ordered magnetic field, a transition towards turbulence and magnetic disorder follows after magnetic reconnection and energy dissipation during the prompt emission phase. In this process, the configuration of the magnetic field evolves with time, rendering it impossible to entirely categorize the magnetic field as ordered. Therefore, we assumed a crude model that incorporates a random magnetic field and an ordered magnetic field, and takes into account the proportionality of the random magnetic field strength to the ordered magnetic field, in order to compute the polarization degree (PD) curve for an individual pulse. It has been discovered that the random magnetic field has a significant impact on the PD results of the low-energy X-ray. In an ordered magnetic field, the X-ray segment maintains a significant PD compared to those in the hundreds of keV and MeV ranges even after electron injection ceases, this making PD easier to detect by polarimetry. However, when the random magnetic field is introduced, the low-energy and high-energy PDs exhibit a similar trend, with the X-ray PD being lower than that of the high-energy segment. Of course, this is related to the rate of disorder in the magnetic field. Additionally, there is two rotation of the polarization angles (PAs) that were not present previously, and the rotation of the PA in the high-energy segment occurs slightly earlier. These results are unrelated to the structure of the ordered magnetic field.

astro-ph.HE

Simulation of a Xe-based X-ray Polarimeter at 10-30 keV

Polarization detection of X-rays is a non-negligible topic to astrophysical observation. Many polarization detection methods have been well developed for X-rays in the energy range below 10~keV, while the detection at 10-30~keV is rarely discussed. This paper presents a simulation study of a Xe-based gas pixel detector, which can achieve the polarization detection of X-rays at 10-30~keV. To verify the emission angle distribution of photoelectrons, different electromagnetic models in Geant4 were investigated. After a necessary modification by considering the missing factor when sampling the emission angle, a good agreement can be achieved. Moreover, the detection capability of 20~keV polarized photons was discussed and the modulation factor could be 43\%.

astro-ph.IM

Magnetar as Central Engine of Gamma-Ray Bursts: Quasi-Universal Jet, Event Rate and X-ray Luminosity Function of Dipole Radiations

Early shallow-decaying X-ray afterglows of gamma-ray bursts (GRBs) may be attributed to the dipole radiations of newly-born magnetars. Assuming that the GRB jets powered by magnetars are quasi-universal, we find that the jet structure can be parameterized as a uniform jet with a luminosity of $\log L_{\rm j}/{\rm erg\ s^{-1}}=52.68^{+0.76}_{-0.33}$ (1$σ$) and an opening angle $θ_{\rm j}=2.10_{-1.28}^{+1.90}$ (50\% confidence level), surrounding by a power-law decay component with an index of ${-4.00^{+0.27}_{-0.37}}$ (1$σ$). The inferred local GRB rate is $ρ=9.6$ Gpc$^{-3}$ yr$^{-1}$ by including both the typical GRBs and LL-GRBs as the same population. The typical viewing angle is $3.3^{o}$, and may be $20^{o}\sim30^{o}$ for LL-GRBs. The X-ray luminosity function of the dipole radiation wind can be empirically described by a broken power-law function with indices $β_1=0.78^{+0.16}_{-0.15}$ and $β_2>1.6$ broken at $\log L_{b, w}/{\rm erg\ s^{-1}}=48.51^{+0.53}_{-0.65}$. In case of that the wind outflow is collimated and co-axial with the GRB jet, we find that the wind structure is similar to the GRB jet, i.e., $\log L_{\rm c, w}/{\rm erg\ s^{-1}}=48.38^{+0.30}_{-0.48}$, $θ_{\rm c, w}={2.65^{o}}_{-1.19^{o}}^{+0.1.73^{o}}$, and $k_{\rm w}=4.57^{+1.21}_{-0.75}$. The observed correlation between the prompt gamma-ray luminosity and X-ray luminosity of the wind may be resulted from the viewing angle effect in such a jet-wind system. Discussion on survey with the X-ray instruments on board the {\em Einstein\ Probe} mission in the soft X-ray band for the jet and wind emission is also presented.

astro-ph.HE

Jet Structure in the Afterglow Phase for Gamma-ray Bursts with a Precessing Jet

The structured jet is involved to explain the afterglows and even the prompt emission of GRB 170817A. In this paper, we stress that for a precessing jet, the jet structure in the prompt emission phase and that in the afterglow phase may be different. The jet structure in the afterglow phase can be non-uniform even if a narrow-uniform jet is presented in the prompt emission phase. We estimate the jet structure in the afterglow phase under the situation that a narrow-uniform-precessing jet is launched from the central engine of gamma-ray burst. With different precession angles, it is found that the structured jet can be roughly described as follows: a narrow uniform core with power-law wings and sharp cut-off edges, a Gaussian profile, a ring shape, or other complex profile in energy per solid angle. Correspondingly, the afterglows for our obtained structured jets are also estimated. We find that the estimates of the intrinsic kinetic energy, the electron index, and the jet opening angle based on the afterglows formed in a precessing system may be incorrect. Our obtained structured jet is likely to be revealed by future observations for a fraction of gravitational wave detected merging compact binary systems (e.g., black hole-neutron star mergers).

astro-ph.HE

A comprehensive analysis of Fermi Gamma-Ray Burst Data: IV. Spectral lag and Its Relation to Ep Evolution

The spectral evolution and spectral lag behavior of 92 bright pulses from 84 gamma-ray bursts (GRBs) observed by the Fermi GBM telescope are studied. These pulses can be classified into hard-to-soft pulses (H2S, 64/92), H2S-dominated-tracking pulses (21/92), and other tracking pulses (7/92). We focus on the relationship between spectral evolution and spectral lags of H2S and H2S-dominated-tracking pulses. %in hard-to-soft pulses (H2S, 64/92) and H2S-dominating-tracking (21/92) pulses. The main trend of spectral evolution (lag behavior) is estimated with $\log E_p\propto k_E\log(t+t_0)$ (${\hatτ} \propto k_{\hatτ}\log E$), where $E_p$ is the peak photon energy in the radiation spectrum, $t+t_0$ is the observer time relative to the beginning of pulse $-t_0$, and ${\hatτ}$ is the spectral lag of photons with energy $E$ with respect to the energy band $8$-$25$ keV. For H2S and H2S-dominated-tracking pulses, a weak correlation between $k_{\hatτ}/W$ and $k_E$ is found, where $W$ is the pulse width. We also study the spectral lag behavior with peak time $t_{\rm p_E}$ of pulses for 30 well-shaped pulses and estimate the main trend of the spectral lag behavior with $\log t_{\rm p_E}\propto k_{t_p}\log E$. It is found that $k_{t_p}$ is correlated with $k_E$. We perform simulations under a phenomenological model of spectral evolution, and find that these correlations are reproduced. We then conclude that spectral lags are closely related to spectral evolution within the pulse. The most natural explanation of these observations is that the emission is from the electrons in the same fluid unit at an emission site moving away from the central engine, as expected in the models invoking magnetic dissipation in a moderately-high-$σ$ outflow.

astro-ph.HE

Study of a sealed high gas pressure THGEM detector and response of Alpha particle spectra

A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under high pressure of 2 atm mainly consist in selecting optimal voltages for ionization region and induction region. The dependence of the shape of Alpha particle spectra measured with relative gas gain on gas pressure (1.3 $\sim$ 2.0 atm) has been studied. The 8 groups of relative gas gain versus working voltage of THGEM expressed by weighting filed $E/P$ are normalized, being consistent with theory. The results show that the air tightness of the chamber is good measured by a sensitive barometer and checked with gas gain. The experimental results are compared with Monte Carlo simulation on energy deposition without gas gain involved.

physics.ins-det

A Novel Method of Encoded Multiplexing Readout for Micro-pattern Gas Detectors

The requirement of a large number of electronic channels poses a big challenge for Micro-pattern Gas Detector (MPGD) to achieve good spatial resolution. By using the redundancy that at least two neighboring strips record the signal of a particle, a novel method of encoded multiplexing readout for MPGDs is presented in this paper. The method offers a feasible and easily-extensible way of encoding and decoding, and can significantly reduce the number of readout channels. A verification test was carried out on a 5*5 cm2 Thick Gas Electron Multiplier (THGEM) detector using a 8 keV Cu X-ray source with 100um slit, where 166 strips are read out by 21 encoded readout channels. The test results show a good linearity in its position response, and the spatial resolution root-mean-square (RMS) of the test system is about 260 μm. This method has an attractive potential to build large area detectors and can be easily adapted to other detectors like MPGDs.

physics.ins-det

Experimental study of THGEM detector with mini-rim

The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10μm) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double THGEM respectively, while the energy resolution of 5.9 keV X-ray varied from 18% to 28% for both single and double THGEM detectors of different hole sizes and thicknesses.All the experiments were investigated in mixture of noble gases(argon,neon) and small content of other gases(iso-butane,methane) at atmospheric pressure.

physics.ins-det