SearcharxivSearch

arXiv subjects

Hubert Kroha

Publications and source records attributed to Hubert Kroha.

17 recordsLinked to original sources

Commissioning of proANUBIS: A proof-of-concept detector for the ANUBIS experiment

Long-lived particles (LLPs), predicted by various extensions of the Standard Model (SM), have become a key focus of the contemporary search programme for physics beyond the SM. To enhance LLP discovery potential at the LHC, the ANUBIS experiment has been proposed to instrument the ceiling of the ATLAS experiment's underground cavern with dedicated tracking detectors. This report summarises recent progress towards realising ANUBIS. Specifically, a key milestone has been achieved with the installation and commissioning of proANUBIS, a prototype that serves as a proof-of-concept for ANUBIS. We describe the proANUBIS setup, including its remotely-operated data acquisition system and automatic signal processing chain. The proANUBIS demonstrator is used to evaluate the detector performance under realistic conditions in the UX1 ATLAS experimental cavern, including readout synchronisation with the ATLAS experiment. Furthermore, proANUBIS allows for the direct measurement of relevant background processes in a representative location within the ATLAS cavern, providing input for the simulation of such processes for the future ANUBIS detector. The paper concludes with an update on the current status of the ANUBIS project and its roadmap toward a full-scale implementation in the ATLAS cavern.

hep-ex

Construction of proANUBIS: A proof-of-concept detector for the ANUBIS experiment

The ANUBIS experiment aims to search for long-lived particles at the Large Hadron Collider (LHC) at CERN. To assess the feasibility of the project, a prototype detector, proANUBIS, was designed, constructed, and prepared for installation in the UX1 ATLAS experimental cavern at the LHC. The primary physics goals of proANUBIS are to determine the technical limitations of the detector technology and to explore the ANUBIS detector concept through in-situ measurements of muon and hadron fluxes inside the ATLAS cavern, which can be used to refine Monte Carlo simulations of such fluxes further. This report describes the design and construction of the proANUBIS experimental setup using Resistive Plate Chambers (RPCs), highlighting the possible future use case of the technology for ANUBIS. Details on the RPC technology, construction processes, quality control measures, and performance studies are discussed. Furthermore, the RPC front-end on-detector electronics and data acquisition components of proANUBIS are presented.

hep-ex

Long-term operation of the screen-printed graphite-based resistive coatings on the HPL electrode for the Resistive Plate Chamber

The reliability of large-area Resistive Plate Chambers (RPCs) operated under High-Luminosity Large Hadron Collider (HL-LHC) conditions is governed by the long-term stability and radiation tolerance of screen-printed graphite/phenoxy coatings on high-pressure-laminate (HPL) electrodes. This work presents a comprehensive, end-to-end qualification of such coatings that integrates industrial process control and metrology with controlled humidity/temperature campaigns, extended high-voltage stress testing to decade-scale charge levels, and representative neutron and gamma irradiation at CERN facilities. The results establish reproducible industrial coating production, stable performance under sustained operation and irradiation, and practical acceptance criteria with operating and monitoring guidelines. The study provides a transferable quality-assurance framework for graphite-based resistive coatings on HPL electrodes, enabling reproducible production and reliable RPC performance for the HL-LHC upgrades and for future high-rate collider experiments.

hep-ex

Resistive Plate Chamber Detector Construction and Certification: State-of-the-Art Facilities at the Max Planck Institute for Physics, in Partnership with Industrial Partners

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a few millimeters. Thanks to their relatively low production cost and robust performance in high-background environments, RPCs have become essential components for instrumenting large detection areas in high-energy physics experiments. The growing demand for these advanced RPC detectors, particularly for the High-Luminosity upgrade of the Large Hadron Collider (HL-LHC), necessitates the establishment of new production facilities capable of delivering high-quality detectors at an industrial scale. To address this requirement, a dedicated RPC assembly and certification facility has been developed at the Max Planck Institute for Physics in Munich, leveraging strategic collaborations with industrial partners MIRION and PTS. This partnership facilitated the transfer of advanced, research-level assembly methodologies into robust, scalable industrial processes. Through a structured, phased prototyping and certification approach, initial tests on small-scale ($40 \times 50 \, cm^2$) prototypes validated the scalability and applicability of optimized production procedures to large-scale ($1.0 \times 2.0 \, m^2$) RPC detectors. Currently, the project has entered its final certification phase, involving extensive performance and longevity testing, including a year-long irradiation campaign at CERN's Gamma Irradiation Facility (GIF++). This article details the development and successful industrial implementation of novel assembly techniques, highlighting the enhanced capabilities and reliability of RPC detectors prepared through this industrial-academic collaboration, ensuring readiness for upcoming challenges in high-energy physics detector instrumentation.

physics.ins-det

Performance of small-diameter muon drift tube chambers with new fast readout ASIC at high background rates

Experiments like ATLAS at the HL-LHC or detectors at future hadron colliders need muon detectors with excellent momentum resolution up to the TeV scale both at the trigger and offline reconstruction levels. This requires muon tracking chambers with high spatial resolution even at the highest background fluxes. Drift-tube chambers are the most cost-effective technology for large-area muon systems, providing the required high rate capability and three-dimensional spatial resolution. Thanks to advances in electronics, the new generation small-diameter Muon Drift Tube (sMDT) detectors with 15 mm tube diameter can be used in stand-alone mode up to the background rates expected at future hadron collider experiments, providing event times and second coordinates without additional trigger chambers. New developments in integrated front-end electronics include fast baseline restoration of the shaped signal and picosecond time-to-digital converters for second coordinate measurement with double-sided read-out. Self-triggered operation is now possible using modern high-performance FPGAs for real-time pattern recognition and track reconstruction. A new amplifier shaper discriminator chip in 65 nm TSMC CMOS technology with increased sensitivity and faster baseline recovery has been developed to cope with high background fluxes. Extensive test beam campaigns using sMDT chambers with new readout electronics have been performed at the CERN Gamma Irradiation Facility (GIF++). Results show that the shorter peaking time of the new chip enhances the spatial resolution of the drift tubes by up to 100 $\mu$m at a background rate of 1 MHz, the maximum rate expected at the 100 TeV collider experiment.

hep-ex

Design and performance of a TDC ASIC for the upgrade of the ATLAS Monitored Drift Tube detector

We present the prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for high-luminosity LHC operation. This ASIC is based on a previously submitted demonstrator ASIC designed for timing performance evaluation, and includes all features necessary for the various operation modes, as well as the migration to the TSMC 130 nm CMOS technology. We present the TDC design with the emphasis on added features and performance optimization. Tests of the timing performance demonstrate that this ASIC meets the design specifications. The TDC has a bin size of about 780 ps, and a timing bin variations within 40 ps for all 24 channels with leading and trailing edge digitization, while the power consumption has been limited to 250 mW, corresponding to a consumption of about 5.2 mW per edge measurement.

physics.ins-det

Hardware Implementation of a Fast Algorithm for the Reconstruction of Muon Tracks in ATLAS Muon Drift-Tube Chambers for the First-Level Muon Trigger at the HL-LHC

The High-Luminosity LHC will provide the unique opportunity to explore the nature of physics beyond the Standard Model of strong and electroweak interactions. Highly selective first level triggers are essential for the physics programme of the ATLAS experiment at the HL-LHC where the instantaneous luminosity will exceed the LHC Run 1 instantaneous luminosity by almost an order of magnitude. The ATLAS first level muon trigger rate is dominated by low momentum muons, selected due to the moderate momentum resolution of the resistive plate and thin gap trigger chambers. This limitation can be overcome by including the data of the precision muon drift tube (MDT) chambers in the first level trigger decision. This requires the fast continuous transfer of the MDT hits to the off-detector trigger logic and a fast track reconstruction algorithm performed in the trigger logic. In order to demonstrate the feasibility of reconstructing tracks in MDT chambers within the short available first-level trigger latency of about 3~$μ$s we implemented a seeded Hough transform on the ARM Cortex A9 microprocessor of a Xilinx Zynq FPGA and studied its performance with test-beam data recorded in CERN's Gamma Irradiation Facility. We could show that by using the ARM processor's Neon Single Instruction Multiple Data Engine to carry out 4 floating point operations in parallel the challenging latency requirement can be matched.

physics.ins-det

Performance of New High-Precision Muon Tracking Detectors for the ATLAS Experiment

The goals of the ongoing and planned ATLAS muon detector upgrades are to increase the acceptance for precision muon momentum measurement and triggering and to improve the rate capability of the muon chambers in the high-background regions corresponding to the increasing LHC luminosity. Smalldiameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half the drift-tube diameter of the current ATLAS Muon Drift Tube (MDT) chambers with 30 mm drift tube diameter and otherwise unchanged operating parameters, the sMDT chambers share all the advantages of the MDTs, but have an about an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The construction of twelve chambers for the feet regions of the ATLAS detector has been completed for the installation in the winter shutdown 2016/17 of the Large Hadron Collider. The purpose of this upgrade of the ATLAS muon spectrometer is to increase the acceptance for three-point muon track measurement which substantially improves the muon momentum resolution in the regions concerned.

physics.ins-det

Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades

The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking efficiency and spatial resolution at high counting rates will be achieved with upgraded readout electronics employing improved signal shaping for high counting rates.

physics.ins-det

Performance of the new amplifier-shaper-discriminator chip for the ATLAS MDT chambers at the HL-LHC

The Phase-II Upgrade of the ATLAS Muon Detector requires new electronics for the readout of the MDT drift tubes. The first processing stage, the Amplifier-Shaper-Discriminator (ASD), determines the performance of the readout for crucial parameters like time resolution, gain uniformity, efficiency and noise rejection. An 8-channel ASD chip, using the IBM 130 nm CMOS 8RF-DM technology, has been designed, produced and tested. The area of the chip is 2.2 x 2.9 square mm size. We present results of detailed measurements as well as a comparision with simulation results of the chip behaviour at three different levels of detail.

physics.ins-det

Optimisation of the Read-out Electronics of Muon Drift-Tube Chambers for Very High Background Rates at HL-LHC and Future Colliders

In the ATLAS Muon Spectrometer, Monitored Drift Tube (MDT) chambers and sMDT chambers with half of the tube diameter of the MDTs are used for precision muon track reconstruction. The sMDT chambers are designed for operation at high counting rates due to neutron and gamma background irradiation expected for the HL-LHC and future hadron colliders. The existing MDT read-out electronics uses bipolar signal shaping which causes an undershoot of opposite polarity and same charge after a signal pulse. At high counting rates and short electronics dead time used for the sMDTs, signal pulses pile up on the undershoot of preceding background pulses leading to a reduction of the signal amplitude and a jitter in the drift time measurement and, therefore, to a degradation of drift tube efficiency and spatial resolution. In order to further increase the rate capability of sMDT tubes, baseline restoration can be used in the read-out electronics to suppress the pile-up effects. A discrete bipolar shaping circuit with baseline restoration has been developed and used for reading out sMDT tubes under irradiation with a 24 MBq 90Sr source. The measurements results show a substantial improvement of the performance of the sMDT tubes at high counting rates.

physics.ins-det

Precision Muon Tracking Detectors for High-Energy Hadron Colliders

Small-diameter muon drift tube (sMDT) chambers with 15 mm tube diameter are a cost-effective technology for high-precision muon tracking over large areas at high background rates as expected at future high-energy hadron colliders including HL-LHC. The chamber design and construction procedures have been optimized for mass production and provide sense wire positioning accuracy of better than 10 ?m. The rate capability of the sMDT chambers has been extensively tested at the CERN Gamma Irradiation Facility. It exceeds the one of the ATLAS muon drift tube (MDT) chambers, which are operated at unprecedentedly high background rates of neutrons and gamma-rays, by an order of magnitude, which is sufficient for almost the whole muon detector acceptance at FCC-hh at maximum luminosity. sMDT operational and construction experience exists from ATLAS muon spectrometer upgrades which are in progress or under preparation for LHC Phase 1 and 2.

physics.ins-det

Construction and Test of New Precision Drift-Tube Chambers for the ATLAS Muon Spectrometer

ATLAS muon detector upgrades aim for increased acceptance for muon triggering and precision tracking and for improved rate capability of the muon chambers in the high-background regions of the detector with increasing LHC luminosity. The small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half of the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages of the MDTs, but have an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, minimizing construction time and personnel. Sense wire positioning accuracies of 5 ?micons have been achieved in serial production for large-size chambers comprising several hundred drift tubes. The construction of new sMDT chambers for installation in the 2016/17 winter shutdown of the LHC and the design of sMDT chambers in combination with new RPC trigger chambers for replacement of the inner layer of the barrel muon spectrometer are in progress.

physics.ins-det

Precision Muon Tracking at Future Hadron Colliders with sMDT Chambers

Small-diameter muon drift tube (sMDT) chambers are a cost-effective technology for high-precision muon tracking. The rate capability of the sMDT chambers has been extensively tested at the Gamma Irradiation Facility at CERN in view of expected rates at future high-energy hadron colliders. Results show that it fulfills the requirements over most of the acceptance of muon detectors. The optimization of the read-out electronics to further increase the rate capability of the detectors is discussed. Chambers of this type are under construction for upgrades of the muon spectrometer of the ATLAS detector at high LHC luminosities. Design and construction procedures have been optimized for mass production while providing a precision of better than 10 micrometers in the sense wire positions and the mechanical stability required to cover large areas.

physics.ins-det

Construction and test of high precision drift-tube (sMDT) chambers for the ATLAS muon spectrometer

For the upgrade of the ATLAS muon spectrometer in March 2014 new muon tracking chambers (sMDT) with drift-tubes of 15 mm diameter, half of the value of the standard ATLAS Monitored Drift-Tubes (MDT) chambers, and 10~$μ$m positioning accuracy of the sense wires have been constructed. The new chambers are designed to be fully compatible with the present ATLAS services but, with respect to the previously installed ATLAS MDT chambers, they are assembled in a more compact geometry and they deploy two additional tube layers that provide redundant rack information. The chambers are composed of 8 layers of in total 624 aluminium drift-tubes. The assembly of a chamber is completed within a week. A semi-automatized production line is used for the assembly of the drift-tubes prior to the chamber assembly. The production procedures and the quality control tests of the single components and of the complete chambers will be discussed. The wire position in the completed chambers have been measured by using a coordinate measuring machine.

physics.ins-det

High Rate Proton Irradiation of 15mm Muon Drifttubes

Future LHC luminosity upgrades will significantly increase the amount of background hits from photons, neutrons and protons in the detectors of the ATLAS muon spectrometer. At the proposed LHC peak luminosity of 5*10^34 1/cm^2s, background hit rates of more than 10 kHz/cm^2 are expected in the innermost forward region, leading to a loss of performance of the current tracking chambers. Based on the ATLAS Monitored Drift Tube chambers, a new high rate capable drift tube detecor using tubes with a reduced diameter of 15mm was developed. To test the response to highly ionizing particles, a prototype chamber of 46 15mm drift tubes was irradiated with a 20 MeV proton beam at the tandem accelerator at the Maier-Leibnitz Laboratory, Munich. Three tubes in a planar layer were irradiated while all other tubes were used for reconstruction of cosmic muon tracks through irradiated and non-irradiated parts of the chamber. To determine the rate capability of the 15mm drift-tubes we investigated the effect of the proton hit rate on pulse height, efficiency and spatial resolution of the cosmic muon signals.

physics.ins-det

Upgrade of the ATLAS Muon Trigger for the SLHC

The outer shell of the ATLAS experiment at the LHC consists of a system of toroidal air-core magnets in order to allow for the precise measurement of the transverse momentum p$_T$ of muons, which in many physics channels are a signature of interesting physics processes. For the precise determination of the muon momentum Monitored Drift Tube chambers (MDT) with high position accuracy are used, while for the fast identification of muon tracks chambers with high time resolution are used, able to select muons above a predefined p$_T$ threshold for use in the first Level of the ATLAS triggering system (Level-1 trigger). When the luminosity of the LHC will be upgraded to 4-5 times the present nominal value (SLHC) in about a decade from now, an improvement of the selectivity of the ATLAS Level-1 triggering system will be mandatory in order to cope with the maximum allowed trigger rate of 100 kHz. For the Level-1 trigger of the ATLAS muon spectrometer this means an increase of the p$_T$ threshold for single muons. Due to the limited spatial resolution of the trigger chambers, however, the selectivity for tracks above ~20 GeV/c is insufficient for an effective reduction of the Level-1 rate. We describe how the track coordinates measured in the MDT precision chambers can be used to decisively improve the selectivity for high momentum tracks. The resulting increase in latency will also be discussed.

physics.ins-det