SearcharxivSearch

arXiv subjects

Hyun-Gue Hong

Publications and source records attributed to Hyun-Gue Hong.

11 recordsLinked to original sources

Strontium ${}^{1}S_{0}\!\rightarrow\!{}^{1}P_{1}$ transition frequency measurements assisted by a photonic grating chip

We measure the absolute frequency of the ${}^{1}S_{0}\!\rightarrow\!{}^{1}P_{1}$ transition in strontium using two methods: fluorescence spectroscopy of a thermal atomic beam source from a compact low-power oven and velocity measurements of a slow atomic beam from a two-dimensional grating magneto-optical trap (2D gMOT). The measurements for both methods are performed in the same ultra-high vacuum chamber containing a diffraction grating chip which is placed below the strontium atoms that are being interrogated. The first method uses a probe laser beam incident on the grating chip such that the grating acts as an end mirror, with the first-order diffracted beam providing a retro-reflected probe beam. The counter-propagating laser beams traverse an atomic beam emitted from an oven, enabling spatially resolved fluorescence spectroscopy through CCD imaging and hyperfine-constrained multi-isotope fitting. The second method relies on a large profile cooling laser beam normally incident onto the grating chip which laser cools strontium atoms for a slow atomic beam source. The velocity of the atoms exiting the 2D gMOT is measured as a function of the laser detuning and intensity from which the resonance frequency can be estimated. The two methods are consistent within their quoted uncertainties. Using three datasets based on retro-beam spectroscopy measurements, and one dataset using slow atom beam velocity measurements, we determine the ${}^{1}S_{0}\!\rightarrow\!{}^{1}P_{1}$ transition frequency to be $650.503\,815(5)~\mathrm{THz}$. Our result provides a re-evaluation of this $461$ nm transition demonstrated on a compact laser cooling apparatus based on a diffraction grating platform.

physics.atom-ph

FPGA-based disturbance-observer servo for broadband noise suppression in laser frequency stabilization

We have demonstrated broadband frequency-noise suppression in a laser stabilization system by augmenting a conventional proportional-integral-derivative (PID) controller with a digital disturbance observer (DOB) implemented on a field-programmable gate array (FPGA). The DOB employs a first-order exponential moving average filter as its Q-filter, replacing multi-parameter frequency-domain plant identification with a single one-dimensional gain sweep. Using modulation transfer spectroscopy on the 87Rb D2 line at 780.24 nm, we have measured the frequency-noise power spectral density and the Allan deviation of the beat note between two independently stabilized lasers. The integrated rms frequency noise below 40 kHz decreased by 16.9 dB compared with PID alone, corresponding to a reduction from approximately 140 kHz to 20 kHz. The short-term fractional frequency instability improved from sigma_y(1 ms) = $7.9 \times 10^{-12}$ to $4.6 \times 10^{-12}$, while the long-term stability at tau > 1 s remained within statistical uncertainty. This DOB-augmented architecture offers a simple and effective route to enhanced noise rejection in FPGA-based servo systems for atomic physics experiments.

physics.atom-ph

High-stability offset-frequency locking of two lasers using a balanced filter discriminator

We demonstrate a high-stability laser offset-frequency locking technique based on a balanced filter discriminator. The beat note between two 852 nm external-cavity diode lasers is down-converted in two parallel arms using local-oscillator frequencies placed symmetrically around the desired offset frequency. After low-pass filtering and RMS detection, differential subtraction of the two detector outputs produces a dispersive frequency-error signal with a zero crossing primarily defined by the reference local-oscillator frequencies. This balanced configuration reduces sensitivity to common beat-power fluctuations and can improve the effective error-signal signal-to-noise ratio. The system was implemented for an 8.653 GHz offset corresponding to the cesium repumping frequency difference used in our laser-cooling setup. Measurements with different low-pass filters reveal a trade-off between discrimination sensitivity and feedback bandwidth. With an SLP-1.9+ filter, the locked beat frequency reached a fractional instability of $4\times10^{-15}$ at 10 s when referred to the 852 nm optical carrier. The residual dependence on photodetector optical power was also characterized, showing that amplitude-to-frequency conversion remains small in the optimized differential configuration. This approach provides a practical frequency-only offset-locking method for atomic-physics experiments requiring stable and tunable microwave-scale laser frequency offsets.

physics.atom-ph

Improved Absolute Frequency Measurement of the 171Yb Optical Lattice Clock at KRISS Relative to the SI Second

We measured the absolute frequency of the $^1S_0$ - $^3P_0$ transition of $^{171}$Yb atoms confined in a one-dimensional optical lattice relative to the SI second. The determined frequency was 518 295 836 590 863.38(57) Hz. The uncertainty was reduced by a factor of 14 compared with our previously reported value in 2013 due to the significant improvements in decreasing the systematic uncertainties. This result is expected to contribute to the determination of a new recommended value for the secondary representations of the second.

physics.atom-ph

Drift-compensated Low-noise Frequency Synthesis Based on a cryoCSO for the KRISS-F1

In this paper we report on the implementation and stability analysis of a drift-compensated frequency synthesizer from a cryogenic sapphire oscillator (CSO) designed for a Cs/Rb atomic fountain clock. The synthesizer has two microwave outputs of 7 GHz and 9 GHz for Rb and Cs atom interrogation, respectively. The short-term stability of these microwave signals, measured using an optical frequency comb locked to an ultra-stable laser, is better than $5\times10^{-15}$ at an averaging time of 1 s. We demonstrate that the short-term stability of the synthesizer is lower than the quantum projection noise limit of the Cs fountain clock, KRISS-F1(Cs) by measuring the short-term stability of the fountain with varying trapped atom number. The stability of the fountain at 1-s averaging time reaches $2.5\times10^{-14}$ at the highest atom number in the experiment when the synthesizer is used as an interrogation oscillator of the fountain. In order to compensate the frequency drift of the CSO, the output frequency of a waveform generator in the synthesis chain is ramped linearly. By doing this, the stability of the synthesizer at an average time of one hour reaches a level of $10^{-16}$ which is measured with the fountain clock.

physics.ins-det

Three-dimensional imaging of cavity vacuum with single atoms localized by a nanohole array

Zero-point electromagnetic fields were first introduced to explain the origin of atomic spontaneous emission. Vacuum fluctuations associated with the zero-point energy in cavities are now utilized in quantum devices such as single-photon sources, quantum memories, switches and network nodes. Here we present three-dimensional (3D) imaging of vacuum fluctuations in a high-Q cavity based on the measurement of position-dependent emission of single atoms. Atomic position localization is achieved by using a nanoscale atomic beam aperture scannable in front of the cavity mode. The 3D structure of the cavity vacuum is reconstructed from the cavity output. The root mean squared amplitude of the vacuum field at the antinode is also measured to be 0.92+-0.07V/cm. The present work utilizing a single atom as a probe for sub-wavelength imaging demonstrates the utility of nanometre-scale technology in cavity quantum electrodynamics.

quant-ph

Quantum theory of frequency pulling in the cavity-QED microlaser

The spectrum of the cavity-QED microlaser/micromaser is expected to show distinctive features of the coherent light-matter interaction, which are obscured in the conventional Schawlow-Townes linewidth theory. However, the spectral studies has been limited to resonant atom-cavity interaction so far. Here we consider the dispersive interaction in the off-resonance case, from which we uncover a quantum frequency pulling effect in the microlaser/micromaser spectrum. We present a quantum theory of the spectrum which introduces the notion of a frequency-pulling distribution associated with the photon number. In contrast to the conventional laser, periodic variation of the mean frequency pulling is observed with increasing pump parameter and it is attributed to the strong atom-cavity coupling. The pulling distribution gives rise to a spectral broadening, which can be dominant over the non-dispersive broadening addressed in the previous works. We also developed a corresponding semiclassical theory and discuss how the introduction of the frequency shift fits in with the extended quantum theory.

quant-ph

Rigorous criterion for characterizing correlated multiphoton emissions

Strong correlation of photons, particularly in the single-photon regime, has recently been exploited for various applications in quantum information processing. Existing correlation measurements, however, do not fully characterize multi-photon correlation in a relevant context and may pose limitations in practical situations. We propose a conceptually rigorous, but easy-to-implement, criterion for detecting correlated multi-photon emission out of a quantum optical system, drawn from the context of wavefunction collapse. We illustrate the robustness of our approach against experimental limitations by considering an anharmonic optical system.

quant-ph

Atomic Solc filter: multi-resonant photoemission via periodic poling of atom-cavity coupling constant

This paper describes a novel atom-cavity interaction induced by periodically poled atom-cavity coupling constant which leads to multiple narrow photoemission bands for an initially inverted two-level atom under the strong coupling condition. The emission bandpass narrowing has a close analogy with the folded Solc filter in the context of quasi-phase matching by periodic poling. We present a closed form solution of the emission probability at the end of interaction and deduce the multiple phase matching condition for this system which is programmable by the interaction time. The Bloch sphere analysis provides a clear understanding of the underlying atomic dynamics associated with the multiple resonances in the semiclassical limit. Furthermore, we show that this interaction can be applied to generation of the nonclassical field with sub-Poisson photon statistics.

quant-ph

Lineshape measurement of an extreme-weak amplitude-fluctuating light source by the photon-counting-based second-order correlation spectroscopy

We demonstrate lineshape measurement of an extreme-weak amplitude fluctuating light source by using the photon-counting-based second-order correlation spectroscopy combined with the heterodyne technique. The amplitude fluctuation of a finite bandwidth introduces a low-lying spectral structure in the lineshape and thus its effect can be isolated from that of the phase fluctuation. Our technique provides extreme sensitivity suited for single-atom-level applications.

physics.optics

Analysis on the effect of technical fluctuations on laser lineshape

We analyze theoretically the effect of technical fluctuations on laser lineshape in terms of statistics of amplitude and phase noise and their respective bandwidths. While the phase noise tends to broaden the linewidth as the magnitude of the noise increases, the amplitude noise brings out an additional structure with its spectral density reflecting the magnitude of the noise. The effect of possible coupling between those two noises is also discussed.

physics.optics