SearcharxivSearch

arXiv subjects

I. Fiori

Publications and source records attributed to I. Fiori.

14 recordsLinked to original sources

Seismic array measurements at Virgo's West End Building for the configuration of a Newtonian-noise cancellation system

Terrestrial gravity fluctuations produce so-called Newtonian noise (NN) which is expected to limit the low frequency sensitivity of existing gravitational-waves (GW) detectors LIGO and Virgo, when they will reach their full potential, and of next-generation detectors like the Einstein Telescope. In this paper, we present a detailed characterization of the seismic field at Virgo's West End Building as part of the development of a Newtonian noise cancellation system. The cancellation system will use optimally filtered data from a seismometer array to produce an estimate of the Newtonian-noise generated by the seismic field, and to subtract this estimate from the gravitational-wave channel of the detector. By using an array of 38 seismic sensors, we show that, despite the influence of the complexity of Virgo's infrastructure on the correlation across the array, Wiener filtering can still be very efficient in reconstructing the seismic field around the test-mass location. Taking into account the division of the building's foundations into separate concrete slabs, and the different properties of the seismic field across them, we conclude that the arrays to be used for the Newtonian-noise cancellation at Virgo will require a relatively large number of seismometers per test mass, i.e. significantly more than 10. Moreover, observed variations of the absolute noise residuals over time, related to the daily evolution of anthropogenic noise, suggest that the Wiener filter will need to be updated regularly, probably more often than every hour, to achieve stationarity of the background level after subtraction.

astro-ph.IM

Investigation of magnetic noise in Advanced Virgo

The Advanced Virgo (AdV) sensitivity might be influenced by the effects of environmental noise, in particular magnetic noise (MN). In order to show the impact on the gravitational-wave strain signal h(t) and on the AdV sensitivity, we must understand the coupling between the environmental magnetic activity and the strain. The relationship between the environmental noise - measured by a physical environment monitor (PEM) - and h(t) is investigated using injection studies, where an intentional stimulus is introduced and the responses of both PEM sensors and the instrument are analyzed. We also present the most outstanding measurements and results obtained from both the characterization and the mitigation studies of the environmental MN. Results show that MN does not affect AdV sensitivity up to $\approx 100$ Mpc in BNS range.

astro-ph.IM

Magnetic coupling to the Advanced Virgo payloads and its impact on the low frequency sensitivity

We study the electromagnetic coupling of the Advanced Virgo (AdV) Input Mirror Payload (IMP) in response to a slowly time-varying magnetic field. As the problem is not amenable to analytical solution, we employ and validate a finite element (FE) analysis approach. The FE model is built to represent as faithfully as possible the real object and it has been validated by comparison with experimental measurements. The intent is to estimate the induced currents and the magnetic field in the neighbourhood of the payload. The procedure found 21 equivalent electrical configurations that are compatible with the measurements. These have been used to compute the magnetic noise contribution to the total AdV strain noise. At the current stage of development AdV seems to be unaffected by magnetic noise, but we foresee a non-negligible coupling once AdV reaches the design sensitivity.

physics.ins-det

Advanced Virgo: a 2nd generation interferometric gravitational wave detector

Advanced Virgo is the project to upgrade the Virgo interferometric detector of gravitational waves, with the aim of increasing the number of observable galaxies (and thus the detection rate) by three orders of magnitude. The project is now in an advanced construction phase and the assembly and integration will be completed by the end of 2015. Advanced Virgo will be part of a network with the two Advanced LIGO detectors in the US and GEO HF in Germany, with the goal of contributing to the early detections of gravitational waves and to opening a new observation window on the universe. In this paper we describe the main features of the Advanced Virgo detector and outline the status of the construction.

gr-qc

Reconstruction of the gravitational wave signal $h(t)$ during the Virgo science runs and independent validation with a photon calibrator

The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity. In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series $h(t)$ from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the $h(t)$ signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed $h(t)$ signal and the associated uncertainties. The uncertainties of the $h(t)$ time series are estimated to be 8% in amplitude. The uncertainty of the phase of $h(t)$ is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 $μ$s at high frequency. A bias lower than $4\,\mathrm{μs}$ and depending on the sky direction of the GW is also present.

gr-qc

Characterization of the Virgo Seismic Environment

The Virgo gravitational wave detector is an interferometer (ITF) with 3km arms located in Pisa, Italy. From July to October 2010, Virgo performed its third science run (VSR3) in coincidence with the LIGO detectors. Despite several techniques adopted to isolate the interferometer from the environment, seismic noise remains an important issue for Virgo. Vibrations produced by the detector infrastructure (such as air conditioning units, water chillers/heaters, pumps) are found to affect Virgo's sensitivity, with the main coupling mechanisms being through beam jitter and scattered light processes. The Advanced Virgo (AdV) design seeks to reduce ITF couplings to environmental noise by having most vibration-sensitive components suspended and in-vacuum, as well as muffle and relocate loud machines. During the months of June and July 2010, a Guralp-3TD seismometer was stationed at various locations around the Virgo site hosting major infrastructure machines. Seismic data were examined using spectral and coherence analysis with seismic probes close to the detector. The primary aim of this study was to identify noisy machines which seismically affect the ITF environment and thus require mitigation attention. Analyzed machines are located at various distances from the experimental halls, ranging from 10m to 100m. An attempt is made to measure the attenuation of emitted noise at the ITF and correlate it to the distance from the source and to seismic attenuation models in soil.

gr-qc

Calibration and sensitivity of the Virgo detector during its second science run

The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.

gr-qc

Virgo calibration and reconstruction of the gravitational wave strain during VSR1

Virgo is a kilometer-length interferometer for gravitational waves detection located near Pisa. Its first science run, VSR1, occured from May to October 2007. The aims of the calibration are to measure the detector sensitivity and to reconstruct the time series of the gravitational wave strain h(t). The absolute length calibration is based on an original non-linear reconstruction of the differential arm length variations in free swinging Michelson configurations. It uses the laser wavelength as length standard. This method is used to calibrate the frequency dependent response of the Virgo mirror actuators and derive the detector in-loop response and sensitivity within ~5%. The principle of the strain reconstruction is highlighted and the h(t) systematic errors are estimated. A photon calibrator is used to check the sign of h(t). The reconstructed h(t) during VSR1 is valid from 10 Hz up to 10 kHz with systematic errors estimated to 6% in amplitude. The phase error is estimated to be 70 mrad below 1.9 kHz and 6 micro-seconds above.

gr-qc

Displacement power spectrum measurement of a macroscopic optomechanical system at thermal equilibrium

The mirror relative motion of a suspended Fabry-Perot cavity is studied in the frequency range 3-10 Hz. The experimental measurements presented in this paper, have been performed at the Low Frequency Facility, a high finesse optical cavity 1 cm long suspended to a mechanical seismic isolation system identical to that one used in the VIRGO experiment. The measured relative displacement power spectrum is compatible with a system at thermal equilibrium within its environmental. In the frequency region above 3 Hz, where seismic noise contamination is negligible, the measurement distribution is stationary and Gaussian, as expected for a system at thermal equilibrium. Through a simple mechanical model it is shown that: applying the fluctuation dissipation theorem the measured power spectrum is reproduced below 90 Hz and noise induced by external sources are below the measurement.

gr-qc

Phenomenological study of the atypical heavy flavor production observed at the Fermilab Tevatron

We address known discrepancies between the heavy flavor properties of jets produced at the Tevatron collider and the prediction of conventional-QCD simulations. In this study, we entertain the possibility that these effects are real and due to new physics. We show that all anomalies can be simultaneously fitted by postulating the additional pair production of light bottom squarks with a 100% semileptonic branching fraction.

hep-ex

Search for narrow resonances below the Upsilon mesons

We have investigated the invariant mass spectrum of dimuons collected by the CDF experiment during the 1992-1995 run of the Fermilab Tevatron collider to improve the limit on the existence of narrow resonances set by the experiments at the SPEAR e+e- collider. In the mass range 6.3-9.0 GeV/c^2, we derive 90% upper credible limits to the ratio of the production cross section times muonic branching fraction of possible narrow resonances to that of the Y(1S) meson. In this mass range, the average limit varies from 1.7 to 0.5%. This limit is much worse at the mass of 7.2 GeV/c^2 due to an excess of 250+-61 events with a width consistent with the detector resolution.

hep-ex

Study of sequential semileptonic decays of b hadrons produced at the Tevatron

We present a study of rates and kinematical properties of lepton pairs contained in central jets with transverse energy E_T > 15 GeV that are produced at the Fermilab Tevatron collider. We compare the data to a QCD prediction based on the HERWIG and QQ Monte Carlo generator programs.We find that the data are poorly described by the simulation, in which sequential semileptonic decays of single b quarks (b --> l c X with c --> l s X) are the major source of such lepton pairs.

hep-ex

Testing the performance of a blind burst statistic

In this work we estimate the performance of a method for the detection of burst events in the data produced by interferometric gravitational wave detectors. We compute the receiver operating characteristics in the specific case of a simulated noise having the spectral density expected for Virgo, using test signals taken from a library of possible waveforms emitted during the collapse of the core of Type II Supernovae.

gr-qc

The CDF-II Online Silicon Vertex Tracker

The Online Silicon Vertex Tracker is the new CDF-II level 2 trigger processor designed to reconstruct 2-D tracks within the Silicon Vertex Detector with high speed and accuracy. By performing a precise measurement of impact parameters the SVT allows tagging online B events which typically show displaced secondary vertices. Physics simulations show that this will greatly enhance the CDF-II B-physics capability. The SVT has been fully assembled and operational since the beginning of Tevatron RunII in April 2001. In this paper we briefly review the SVT design and physics motivation and then describe its performance during the early phase (April-October 2001) of run II.

hep-ph