SearcharxivSearch

arXiv subjects

I. Vila

Publications and source records attributed to I. Vila.

18 recordsLinked to original sources

Tracking and timing measurements on irradiated TI-LGADs

Trench-isolated (TI) LGADs, developed at FBK, are pixelated LGAD implementations where pads are separated by physical trenches etched within the silicon substrate and filled with a dielectric material. Developed as a solution to the LGAD fill factor problem, this technology provides a path towards 4D tracking with reduced inefficiencies in the interpad regions. Through a dedicated 120 GeV SPS pion test beam campaign, the time resolution, efficiency, and inter-pad distance of carbon infused irradiated TI-LGADs is presented. Fluences up to 2.5$~$x$~$$10^{15}$$~$n$_{\text{eq}}$$~$cm$^{-2}$ are evaluated, for single trench implementations with varied trench width at a temperature of -25 $^o$C. The results show an interpad distance degradation with the irradiation of the detector and an optimal time resolution between 35 ps and 45 ps for all studied devices.

physics.ins-det

Effects of Neutron Irradiation on LGADs with Broad Multiplication Layer and varied Carbon-Enriched Doses: A Study on Timing Performance and Gain Deterioration

In this radiation tolerance study, Low Gain Avalanche Detectors (LGADs) with a carbon-enriched broad and shallow multiplication layer were examined in comparison to identical non-carbonated LGADs. Manufactured at IMB-CNM, the sensors underwent neutron irradiation at the TRIGRA reactor in Ljubljana, reaching a fluence of $2.5 \times 10^{15}n_{eq}cm^{-2}$. The results revealed a smaller deactivation of Boron and improved resistance to radiation in carbonated LGADs. The study demonstrated the potential benefits of carbon enrichment in mitigating radiation damage effects, particularly the acceptor removal mechanism, reducing the acceptor removal constant by more than a factor of two. Additionally, time resolution and collected charge degradation due to irradiation were observed, with carbonated samples exhibiting better radiation tolerance. A noise analysis focused on baseline noise and thermally generated pulses showed the presence of spurious thermal-generated pulses attributed to a excessive small distance between the gain layer end and the p-stop implant at the periphery of the pad for the characterized LGAD design; however, the operation performance of the devices was unaffected.

physics.ins-det

Impact of Neutron Irradiation on LGADs with a Carbon-Enriched Shallow Multiplication Layer: Degradation of Timing Performance and Gain

In this radiation tolerance study, Low Gain Avalanche Detectors (LGADs) with a carbon-enriched broad and shallow multiplication layer were examined in comparison to identical non-carbonated LGADs. Manufactured at IMB-CNM, the sensors underwent neutron irradiation at the TRIGA reactor in Ljubljana, reaching a fluence of $1.5e^{15} {n_{eq}} cm^{-2}$. The results revealed a smaller deactivation of boron and improved resistance to radiation in carbonated LGADs. The study demonstrated the potential benefits of carbon enrichment in mitigating radiation damage effects, particularly the acceptor removal mechanism, reducing the acceptor removal constant by more than a factor of two. Additionally, time resolution and collected charge degradation due to irradiation were observed, with carbonated samples exhibiting better radiation tolerance. A noise analysis focused on baseline noise and spurious pulses showed the presence of thermal-generated dark counts attributed to a too narrow distance between the gain layer end and the p-stop implant at the periphery of the pad for the characterized LGAD design; however, without significant impact of operation performance.

physics.ins-det

First Constraints from DAMIC-M on Sub-GeV Dark-Matter Particles Interacting with Electrons

We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the subelectron charge resolution and low level of dark current of DAMIC-M charge-coupled devices (CCDs). Dark-matter-induced ionization signals above the detector dark current are searched for in CCD pixels with charge up to 7e$^-$. With this dataset we place limits on dark matter particles of mass between 0.53 and 1000 MeV/$c^2$, excluding unexplored regions of parameter space in the mass ranges [1.6,1000] MeV/$c^2$ and [1.5,15.1] MeV/$c^2$ for ultralight and heavy mediator interactions, respectively.

hep-ex

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.

astro-ph.CO

The DAMIC-M Experiment: Status and First Results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

hep-ex

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $γ$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$ $initio$ calculations originally developed for X-ray absorption spectroscopy.

physics.ins-det

Top-Quark Physics at the CLIC Electron-Positron Linear Collider

The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies: 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boson and top-quark physics. The opportunities for top-quark physics at CLIC are discussed in this paper. The initial stage of operation focuses on top-quark pair production measurements, as well as the search for rare flavour-changing neutral current (FCNC) top-quark decays. It also includes a top-quark pair production threshold scan around 350 GeV which provides a precise measurement of the top-quark mass in a well-defined theoretical framework. At the higher-energy stages, studies are made of top-quark pairs produced in association with other particles. A study of ttH production including the extraction of the top Yukawa coupling is presented as well as a study of vector boson fusion (VBF) production, which gives direct access to high-energy electroweak interactions. Operation above 1 TeV leads to more highly collimated jet environments where dedicated methods are used to analyse the jet constituents. These techniques enable studies of the top-quark pair production, and hence the sensitivity to BSM physics, to be extended to higher energies. This paper also includes phenomenological interpretations that may be performed using the results from the extensive top-quark physics programme at CLIC.

hep-ex

Detector Technologies for CLIC

The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.

physics.ins-det

Inverse Low Gain Avalanche Detectors (iLGADs) for precise tracking and timing applications

Low Gain Avalanche Detector (LGAD) is the baseline sensing technology of the recently proposed Minimum Ionizing Particle (MIP) end-cap timing detectors (MTD) at the Atlas and CMS experiments. The current MTD sensor is designed as a multi-pad matrix detector delivering a poor position resolution, due to the relatively large pad area, around 1 $mm^2$; and a good timing resolution, around 20-30 ps. Besides, in his current technological incarnation, the timing resolution of the MTD LGAD sensors is severely degraded once the MIP particle hits the inter-pad region since the signal amplification is missing for this region. This limitation is named as the LGAD fill-factor problem. To overcome the fill factor problem and the poor position resolution of the MTD LGAD sensors, a p-in-p LGAD (iLGAD) was introduced. Contrary to the conventional LGAD, the iLGAD has a non-segmented deep p-well (the multiplication layer). Therefore, iLGADs should ideally present a constant gain value over all the sensitive region of the device without gain drops between the signal collecting electrodes; in other words, iLGADs should have a 100${\%}$ fill-factor by design. In this paper, tracking and timing performance of the first iLGAD prototypes is presented.

physics.ins-det

First Results on 3D Pixel Sensors Interconnected to the RD53A Readout Chip after Irradiation to $1\times$$10^{16}$neq cm$^{-2}$

Results obtained with 3D columnar pixel sensors bump-bonded to the RD53A prototype readout chip are reported. The interconnected modules have been tested in a hadron beam before and after irradiation to a fluence of about $1\times$$10^{16}$neq cm$^{-2}$ (1MeV equivalent neutrons). All presented results are part of the CMS R&D activities in view of the pixel detector upgrade for the High Luminosity phase of the LHC at CERN (HL-LHC). A preliminary analysis of the collected data shows hit detection efficiencies around 97% measured after proton irradiation.

physics.ins-det

First study of small-cell 3D Silicon Pixel Detectors for the High Luminosity LHC

A study of 3D pixel sensors of cell size 50 μm x 50 μm fabricated at IMB-CNM using double-sided n-on-p 3D technology is presented. Sensors were bump-bonded to the ROC4SENS readout chip. For the first time in such a small-pitch hybrid assembly, the sensor response to ionizing radiation in a test beam of 5.6 GeV electrons was studied. Results for non-irradiated sensors are presented, including efficiency, charge sharing, signal-to-noise, and resolution for different incidence angles.

physics.ins-det

Recent Technological Developments on LGAD and iLGAD Detectors for Tracking and Timing Applications

This paper reports the last technological development on the Low Gain Avalanche Detector (LGAD) and introduces a new architecture of these detectors called inverse-LGAD (iLGAD). Both approaches are based on the standard Avalanche Photo Diodes (APD) concept, commonly used in optical and X-ray detection applications, including an internal multiplication of the charge generated by radiation. The multiplication is inherent to the basic n++-p+-p structure, where the doping profile of the p+ layer is optimized to achieve high field and high impact ionization at the junction. The LGAD structures are optimized for applications such as tracking or timing detectors for high energy physics experiments or medical applications where time resolution lower than 30 ps is required. Detailed TCAD device simulations together with the electrical and charge collection measurements are presented through this work.

physics.ins-det

DEPFET active pixel detectors for a future linear $e^+e^-$ collider

The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a sensor thickness of 50-75 $\mathrm{\mathbf{μm}}$. ASICs have been designed and produced to operate a DEPFET pixel detector with the required read-out speed. A complete detector concept is being developed, including solutions for mechanical support, cooling and services. In this paper the status of DEPFET R & D project is reviewed in the light of the requirements of the vertex detector at a future linear $\mathbf{e^+ e^-}$ collider.

physics.ins-det

First investigation of a novel 2D position-sensitive semiconductor detector concept

This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of polycrystalline silicon. A characterization of two proof-of-concept prototypes with different values of the electrode resistivity was carried out using a pulsed Near Infra-Red laser. The experimental data were compared with the electrical simulation of the sensor equivalent circuit coupled to simple electronics readout circuits. The good agreement between experimental and simulation results establishes the soundness of resistive charge division method in silicon microstrip sensors and validates the developed simulation as a tool for the optimization of future sensor prototypes. Spatial resolution in the strip length direction depends on the ionizing event position. The average value obtained from the protype analysis is close to 1.2% of the strip length for a 6 MIP signal.

physics.ins-det

Alignment of Silicon tracking systems R&D on Semitransparent Microstrip Sensors

We summarize the R&D activities on a novel semitransparent microstrip sensor to be used on laser-based alignment systems for silicon trackers. The new sensor is used both for particle tracking and laser detection. The aim of this research line is to increase the optical transmittance (T) of Silicon microstrips detectors to infrared light, introducing minor modifications to the sensor design still suitable for its industrial production. The optical simulations used in the sensor design have been experimentally validated against several patterned material samples. This activities have been carried out in the context of SiLC collaboration for the next International Linear Collider.

physics.ins-det

Performance and First Physics Results of the SVT Trigger at CDF II

For the first time in a hadron collider, a novel trigger processor, the Silicon Vertex Trigger (SVT), allows to select the long-lived heavy flavor particles by cutting on the track impact parameter with a precision similar to that of the offline reconstruction. Triggering on displaced tracks has enriched the B-physics program by enhancing the B yields of the lepton-based triggers and opened up full hadronic triggering at CDF. After a first commissioning period, the SVT is fully operational, performing very closely to its design capabilities. System performance and first physics results based on SVT selected data samples are presented.

hep-ph

The CDFII Time-Of-Flight Detector and Impact on Beauty Flavor Tagging

The new CDFII detector incorporates a Time-of-Flight detector (TOF), employing plastic scintillator bars and fine-mesh photomultipliers. Since August 2001 the TOF system has been fully instrumented and integrated into the CDFII data acquisition system. With a design goal of $100 ps$ resolution the TOF system will provide at least two standard deviations separation between $K^{\pm}$ and $π^{\pm}$ for momenta $p<1.6 GeV/c$, complementing low momentum particle identification by means of the specific ionization energy loss measured in the drift chamber. We describe the design of the TOF detector and discuss the current status of its calibration and initial performances. Finally we review the expected impact of the TOF detector in the flavor tagging of neutral $B_S$ meson.

hep-ex