Influence of Radiation and AC Coupling on Time Performance of Analog Pixels Test Structures in 65 nm CMOS technology

Monolithic Active Pixel Sensors (MAPS) in advanced CMOS imaging technologies are key to next-generation tracking systems for high-energy physics, where radiation hardness and precise vertex reconstruction are essential. As part of the ALICE ITS3 R&D program in synergy with the CERN R&D, we evaluated the performance of the Analog Pixel Test Structures (APTS) fabricated in the TPSCo 65 nm CMOS imaging process. The prototypes employ 10 um pitch pixels with a fast operational amplifier-based buffering stage at the output, enabling direct characterization of intrinsic sensor response. Beam tests with minimum ionizing particles assessed the timing and charge collection of DC- and AC-coupled designs, including devices exposed to 10^14 NIEL and 10^15 NIEL non ioninsing energy loss. DC-coupled sensors demonstrated stable performance, maintaining time resolution lower than 70 ps and >99% detection efficiency up to 10^15 NIEL. AC-coupled sensors demonstrated a wide operational margin, with efficiencies above 99% for clusterization thresholds below 150 electrons. Even though the AC coupling allows higher reverse bias than DC-coupled sensors, the reduced signal amplitude lowers the signal-to-noise ratio, increasing the jitter contribution. At high reverse bias, the AC-coupled sensors achieve time resolutions comparable to the DC-coupled version, demonstrating the viability of both approaches. These results also suggest that combining the low capacitance of DC-coupled designs with the high-bias capability of AC coupling could further enhance time resolution. These results confirm the suitability of 65 nm MAPS for future collider detectors requiring high radiation tolerance, efficiency, and timing precision.

physics.ins-det

Yield, noise and timing studies of ALICE ITS3 stitched sensor test structures: the MOST

In the LHC long shutdown 3, the ALICE experiment upgrades the inner layers of its Inner Tracker System with three layers of wafer-scale stitched sensors bent around the beam pipe. Two stitched sensor evaluation structures, the MOnolithic Stitched Sensor (MOSS) and MOnolithic Stitched Sensor with Timing (MOST) allow the study of yield dependence on circuit density, power supply segmentation, stitching demonstration for power and data transmission, performance dependence on reverse bias, charge collection performance, parameter uniformity across the chip, and performance of wafer-scale data transmission. The MOST measures 25.9 cm x 0.25 cm, has more than 900,000 pixels of 18x18 $\mu$m$^2$ and emphasizes the validation of pixel circuitry with maximum density, together with a high number of power domains separated by switches allowing to disconnect faulty circuits. It employs 1 Gb/s 26 cm long data transmission using asynchronous, data-driven readout. This readout preserves information on pixel address, time of arrival and time over threshold. In the MOSS, by contrast, regions with different in-pixel densities are implemented to study yield dependence and are read synchronously. MOST test results validated the concept of power domain switching and the data transmission over 26 cm stitched lines which are to be employed on the full-size, full-functionality ITS3 prototype sensor, MOSAIX. Jitter of this transmission is still under study. This proceeding summarizes the performance of the stitched sensor test structures with emphasis on the MOST.

physics.ins-det