SearcharxivSearch

arXiv · 2512.13339

Influence of Radiation and AC Coupling on Time Performance of Analog Pixels Test Structures in 65 nm CMOS technology

Abstract

Monolithic Active Pixel Sensors (MAPS) in advanced CMOS imaging technologies are key to next-generation tracking systems for high-energy physics, where radiation hardness and precise vertex reconstruction are essential. As part of the ALICE ITS3 R&D program in synergy with the CERN R&D, we evaluated the performance of the Analog Pixel Test Structures (APTS) fabricated in the TPSCo 65 nm CMOS imaging process. The prototypes employ 10 um pitch pixels with a fast operational amplifier-based buffering stage at the output, enabling direct characterization of intrinsic sensor response. Beam tests with minimum ionizing particles assessed the timing and charge collection of DC- and AC-coupled designs, including devices exposed to 10^14 NIEL and 10^15 NIEL non ioninsing energy loss. DC-coupled sensors demonstrated stable performance, maintaining time resolution lower than 70 ps and >99% detection efficiency up to 10^15 NIEL. AC-coupled sensors demonstrated a wide operational margin, with efficiencies above 99% for clusterization thresholds below 150 electrons. Even though the AC coupling allows higher reverse bias than DC-coupled sensors, the reduced signal amplitude lowers the signal-to-noise ratio, increasing the jitter contribution. At high reverse bias, the AC-coupled sensors achieve time resolutions comparable to the DC-coupled version, demonstrating the viability of both approaches. These results also suggest that combining the low capacitance of DC-coupled designs with the high-bias capability of AC coupling could further enhance time resolution. These results confirm the suitability of 65 nm MAPS for future collider detectors requiring high radiation tolerance, efficiency, and timing precision.

Explore related subjects

Keep this discovery

BibTeXRIS

Gianluca Aglieri Rinella, Luca Aglietta, Matias Antonelli, Francesco Barile, Franco Benotto, Stefania Maria Beole, Elena Botta, Giuseppe Eugenio Bruno, Domenico Colella, Angelo Colelli, Giacomo Contin, Giuseppe De Robertis, Floarea Dumitrache, Domenico Elia, Chiara Ferrero, Martin Fransen, Alessandro Grelli, Hartmut Hillemanns, Isis Hobus, Alex Kluge, Shyam Kumar, Corentin Lemoine, Francesco Licciulli, Bong-Hwi Lim, Flavio Loddo, Esther Mwetaminwa M Bilo, Magnus Mager, Davide Marras, Paolo Martinengo, Cosimo Pastore, Rajendra Nath Patra, Stefania Perciballi, Francesco Piro, Francesco Prino, Luciano Ramello, Felix Reidt, Roberto Russo, Valerio Sarritzu, Umberto Savino, Serhiy Senyukov, Mario Sitta, Walter Snoeys, Jory Sonneveld, Miljenko Suljic, Triloki Triloki, Gianluca Usai, Haakan Wennlof. 2025-12-15. Influence of Radiation and AC Coupling on Time Performance of Analog Pixels Test Structures in 65 nm CMOS technology. https://arxiv.org/abs/2512.13339

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det