SearcharxivSearch

arXiv subjects

Ivan Smiljanic

Publications and source records attributed to Ivan Smiljanic.

5 recordsLinked to original sources

Uncertainties from metrology in the integrated luminosity measurement with the updated design of a detector at CEPC

In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify Bhabha scattering at low polar angles. Usually, such a device is placed at the outgoing beams, to keep the spatial symmetries of the head-on collisions at accelerators with a non-zero crossing angle. At CEPC it is currently proposed to place the luminometer on the z-axis. We review a feasibility of a measurement of the integrated luminosity at the $Z^{0}$ pole with the required precision, concerning the luminometer centered around the z-axis and the post-CDR beam properties.

hep-ex

Very forward calorimeters for future electron-positron colliders

Detectors at future $e^+e^-$ colliders need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered particles. In our concept, two compact calorimeters are foreseen, LumiCal and BeamCal. Both are designed as sandwich calorimeters with very thin sensor planes to keep the Molière radius small, facilitating such the measurement of electron showers in the presence of background. Silicon sensor prototypes and dedicated FE ASICs have been developed and produced. The ASICs match the timing and dynamic range requirements. In the recent beam tests, a multi-plane compact prototype was equipped with thin sensor planes fully assembled with the new readout electronics and installed in 1 mm gaps between tungsten plates of one radiation length thickness. The latest status of the calorimeter prototype development will be presented, including selected performance results, obtained in a 5 GeV electron beam at DESY, as well as the expected performance obtained from simulation.

hep-ex

Systematic uncertainties in integrated luminosity measurement at CEPC

The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams.

physics.ins-det

Beam-spread determination for luminosity measurement at CEPC

Any asymmetry in energy of the colliding beams will lead to a longitudinal boost of the center-of-mass frame of colliding particles w.r.t. the laboratory frame and consequently to the counting loss in luminometer due to the loss of colinearity of Bhabha final states. At CEPC running at the Z0 pole, asymmetry in energy of the colliding beams should be known as well as 12.5% of the beam-spread, in order to control the uncertainty of Bhabha count at the level of 0.01%. Here we discuss the method, initially proposed for FCCee, to determine variation of the beam-spread from the measurement of the effective center-of-mass energy in $e^+e^- \to μ^+μ^-$ collisions.

hep-ex

Forward Instrumentation for ILC Detectors

Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.

physics.ins-det