SearcharxivSearch

arXiv · 1009.2433

Forward Instrumentation for ILC Detectors

Abstract

Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.

Explore related subjects

Keep this discovery

BibTeXRIS

Halina Abramowicz, Angel Abusleme, Konstantin Afanaciev, Jonathan Aguilar, Prasoon Ambalathankandy, Philip Bambade, Matthias Bergholz, Ivanka Bozovic-Jelisavcic, Elena Castro, Georgy Chelkov, Cornelia Coca, Witold Daniluk, Angelo Dragone, Laurentiu Dumitru, Konrad Elsener, Igor Emeliantchik, Tomasz Fiutowski, Mikhail Gostkin, Christian Grah, Grzegorz Grzelak, Gunter Haller, Hans Henschel, Alexandr Ignatenko, Marek Idzik, Kazutoshi Ito, Tatjana Jovin, Eryk Kielar, Jerzy Kotula, Zinovi Krumstein, Szymon Kulis, Wolfgang Lange, Wolfgang Lohmann, Aharon Levy, Arkadiusz Moszczynski, Uriel Nauenberg, Olga Novgorodova, Marin Ohlerich, Marius Orlandea, Gleb Oleinik, Krzysztof Oliwa, Alexander Olshevski, Mila Pandurovic, Bogdan Pawlik, Dominik Przyborowski, Yutaro Sato, Iftach Sadeh, Andre Sailer, Ringo Schmidt, Bruce Schumm, Sergey Schuwalow, Ivan Smiljanic, Krzysztof Swientek, Yosuke Takubo, Eliza Teodorescu, Wojciech Wierba, Hitoshi Yamamoto, Leszek Zawiejski, Jinlong Zhang. 2010-09-13. Forward Instrumentation for ILC Detectors. https://doi.org/10.1088/1748-0221/5/12/p12002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det