Improved $^{94}$Mo neutron resonance parameters from neutron capture and transmission measurements at n_TOF and GELINA

We report high-resolution measurements of the $^{94}\mathrm{Mo}(\mathrm{n},γ)^{95}\mathrm{Mo}$ cross section in the neutron energy range from a few eV up to about 250 keV, performed at the n_TOF facility (CERN), and of the $^{94}\mathrm{Mo}(\mathrm{n},\mathrm{tot})$ cross section up to 32 keV, measured at GELINA (JRC Geel). A combined R-matrix analysis of capture and transmission data yields significantly improved neutron-resonance parameters for $^{94}$Mo. A total of 186 resonances were observed in this analysis of which 127 reported here for the first time. The resulting Maxwellian-averaged cross section at stellar temperatures relevant to the slow neutron-capture process (s-process) is approximately 25% lower than previous evaluations and literature values. To assess the astrophysical impact of the revised cross section, we performed s-process nucleosynthesis calculations for low-mass asymptotic giant branch stars. Despite the substantial reduction in the $^{94}\mathrm{Mo}(\mathrm{n},γ)^{95}\mathrm{Mo}$ rate, the final yields vary by only 3-4%. This demonstrates that the isotopic budget of $^{94}$Mo in AGB stars is primarily governed by the branching flow at $^{94}\mathrm{Nb}$ rather than by the neutron-capture destruction on $^{94}$Mo itself. The new cross section thus helps disentangle nuclear cross-section uncertainties from branching-flow effects in the s-process production of $^{94}$Mo.

nucl-ex

Rethinking Total Absorption Gamma Spectroscopy Deconvolution: Supervised Machine Learning vs Response-Matrix Methods

The extraction of $β$-feeding distributions in Total Absorption $γ$-ray Spectroscopy constitutes a challenging inverse problem, particularly in nuclei with complex decay schemes involving a large number of excited states. In such cases, the measured spectrum arises from the superposition of many detector response functions, making the determination of the individual feedings intrinsically ill-posed and highly sensitive to the methodology employed. In this work, we present a systematic comparison between supervised Machine-Learning techniques and Response-Matrix methods using realistic Monte Carlo simulations of an experimental Total Absorption Spectrometer. Supervised Machine-Learning approaches construct a non-parametric estimator that infers level feedings from the measured spectrum after a training stage, whereas Response-Matrix methods determine the feeding distribution by directly minimizing the difference between measured and reconstructed spectra. Our results show that supervised Machine-Learning techniques achieve superior accuracy in the reconstruction of individual feeding intensities, whereas Response-Matrix methods provide robust and physically consistent initial solutions. These findings support a hybrid strategy in which a Response-Matrix method is first used to obtain an initial feeding estimate, which is then refined using a supervised Machine-Learning approach to achieve improved overall accuracy.

physics.data-an

First $^{94}$Nb($n,γ$) Measurement: Constraining the Nucleosynthetic Origin of $^{94}$Mo in Presolar Grains

Isotopic measurements of presolar silicon carbide grains from dying stars have revealed a puzzling overabundance of $^{94}$Mo that stellar nucleosynthesis models have failed to reproduce for two decades. This discrepancy challenged our understanding of the slow neutron-capture process ($s$-process) that forges approximately half of the elements heavier than iron. The key uncertainty lies at $^{94}$Nb, a radiactive branching point where competition between neutron capture and beta decay governs the $^{94}$Mo production, yet the neutron-capture cross section had never been measured. Here we report the first experimental determination of the $^{94}$Nb(n,$γ$)$^{95}$Nb cross section important for Mo isotopic abundances. The measurement was enabled by a coordinated effort involving high-purity target preparation at Institute of Solid State and Materials Research (IFW) Dresden, radioactive sample production at the Institut Laue-Langevin (ILL) Grenoble, radiochemical characterization at Paul Scherrer Institute (PSI) Villigen, and the Time-of-Flight CERN n$\_$TOF facility using for the first time segmented total-energy detectors. Incorporation of the resulting Maxwellian-averaged cross section into fully coupled nucleosynthesis models of low-mass asymptotic giant branch (AGB) stars brings them into agreement with the presolar grain data. These results remove a major nuclear-physics input uncertainty at the $^{94}$Nb branching point and provide a firmer foundation for understanding the origin of $^{94}$Mo in the solar system.

nucl-ex

Radiative neutron capture cross section of $^{242}$Pu measured at n_TOF-EAR1 in the unresolved resonance region up to 600 keV

Accurate neutron capture cross sections are essential for the design and operation of fast reactors using MOX fuels. For $^{242}$Pu, the Nuclear Energy Agency (NEA) recommends 8--12% accuracy in the fast energy region (2--500 keV), compared to the current uncertainty of 35%. Moreover, integral experiments and previous measurements suggest the evaluated $^{242}$Pu(n,$γ$) cross section is overestimated, particularly in the JEFF-3.3 library, which shows a 14% overestimation between 1 keV and 1 MeV. Recent measurements from LANSCE reported a 20--30% reduction in the 1--40 keV range relative to evaluations. To solve these discrepancies, the $^{242}$Pu(n,$γ$) cross section was measured from 1 to 600 keV at CERN n_TOF-EAR1 facility using a 95(4) mg $^{242}$Pu target, enriched to 99.959%. Gamma rays from neutron capture were detected with an array of C$_6$D$_6$ scintillators and a novel application of the Pulse Height Weighting Technique was employed. The resulting cross section presents a systematic uncertainty between 8 and 12%, reducing the current uncertainties of 35\% and achieving the accuracy requested by the NEA. Analysis using FITACS produced average resonance parameters, consistent with the analysis of the resolved resonance region. Our data align well with Wisshak and Kaeppeler, and are 10--14\% lower than JEFF-3.3 in the 1--250 keV range, helping to achieve consistency with integral benchmarks. At higher energies, our results are in reasonable agreement with ENDF/B-VIII.1 and JEFF-3.3. In contrast, DANCE results appear to underestimate the cross section by a factor of 2--3 above a few keV.

nucl-ex

Imaging neutrons with a position-sensitive monolithic CLYC detector

In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and $γ$-ray Compton scatterer of the novel dual \g-ray and neutron imaging system GN-Vision, which aims at simultaneously obtaining information about the spatial origin of \g-ray and neutron sources. We first investigated the performance of large 50$\times$50~mm$^{2}$ monolithic CLYC crystals coupled to a pixelated SiPM in terms of energy resolution and neutron-gamma discrimination. The response of two different 95\% $^{6}$Li-enriched CLYC detectors coupled to an array of 8$\times$8 SiPMs was studied in comparison to the results of a conventional photo-multiplier tube. Energy resolution ranging from 6-8\% for the $^{137}$Cs peak and a figure of merit of 3-4 for the neutron-gamma discrimination have been obtained. The spatial response of the CLYC-SiPM detector to $γ$-rays and neutrons has also been characterized using charge modulation-based multiplexing techniques based on a diode-coupled charge division circuit. Average resolutions close to 5~mm FWHM with good linearity are obtained in the transverse crystal plane. Last, this work presents the first proof-of-concept experiments of the neutron imaging capability using a neutron pinhole collimator attached to the developed position sensitive CLYC detector.

physics.ins-det

Neutron capture measurements for s-process nucleosynthesis; A review about CERN n_TOF developments and contributions

This article presents a review about the main CERN n\_TOF contributions to the field of neutron-capture experiments of interest for $s$-process nucleosynthesis studies over the last 25 years, with special focus on the measurement of radioactive isotopes. A few recent capture experiments on stable isotopes of astrophysical interest are also discussed. Results on $s$-process branching nuclei are appropriate to illustrate how advances in detection systems and upgrades in the facility have enabled increasingly challenging experiments and, as a consequence, have led to a better understanding and modeling of the $s$-process mechanism of nucleosynthesis. New endeavors combining radioactive-ion beams from ISOLDE for the production of radioisotopically pure samples for activation experiments at the new NEAR facility at n\_TOF are briefly discussed. On the basis of these new exciting results, also current limitations of state-of-the-art TOF and activation techniques will be depicted, thereby showing the pressing need for further upgrades and enhancements on both facilities and detection systems. A brief account of the potential technique based on inverse kinematics for direct neutron-capture measurements is also presented.

nucl-ex

First Pilot Tests of Compton Imaging and Boron Concentration Measurements in BNCT Using i-TED

Dosimetry in BNCT poses significant challenges due to the indirect effect of neutrons interacting with elements within the body and uncertainties associated with the uptake of boron compounds used in clinical practice. Current treatment planning relies on unconventional estimates of boron tumor uptake derived from prior PET scans and thus, an online boron-uptake monitor would be highly convenient. This work presents the first pilot experiments carried out at ILL-Grenoble with the high-efficiency Compton camera i-TED, hereby aiming at demonstrating its applicability for BNCT dosimetry by introducing real-time measurement of the boron concentration and imaging capabilities of spatial dose distribution. In this experiment, we measured the $^{10}$B uptake of different cancer cells of tongue squamous cell carcinoma, malignant melanoma and glioblastoma treated with BPA (80~ppm of $^{10}$B). The samples were irradiated with the thermal neutron spectrum of ILL-Grenoble and the 478keV $γ$-rays from the $^{7}$Li de-excitation after the neutron-boron reaction were registered both with the Compton imager and the high-sensitivity FIPPS HPGe array. These series of measurements allowed us to demonstrate the imaging capabilities of the Compton imaging device for the 478 keV $γ$-rays of interest for dosimetry in BNCT, as well as to assess its sensitivity, which was found to be below 1 $μ$g of $^{10}$B.

physics.med-ph

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called $γ$-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps toward such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n\_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C$_{6}$D$_{6}$ detectors, and one LaCl$_{3}$(Ce) detector. The performance of these detection systems is compared using $^{93}$Nb($n$,$γ$) data. We also developed a detailed \textsc{Geant4} Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a $γ$ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigaged experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

physics.ins-det

Characterization of the LUNA neutron detector array for the measurement of the 13C(a,n)16O reaction

We introduce the LUNA neutron detector array developed for the investigation of the 13C(a,n)16O reaction towards its astrophysical s-process Gamow peak in the low-background environment of the Laboratori Nazionali del Gran Sasso (LNGS). Eighteen 3He counters are arranged in two different configurations (in a vertical and a horizontal orientation) to optimize neutron detection effciency, target handling and target cooling over the investigated energy range Ea;lab = 300 - 400 keV (En = 2.2 - 2.6 MeV in emitted neutron energy). As a result of the deep underground location, the passive shielding of the setup and active background suppression using pulse shape discrimination, we reached a total background rate of 1.23 +- 0.12 counts/hour. This resulted in an improvement of two orders of magnitude over the state of the art allowing a direct measurement of the 13C(a,n)16O cross-section down to Ea;lab = 300 keV. The absolute neutron detection efficiency of the setup was determined using the 51V(p,n)51Cr reaction and an AmBe radioactive source, and completed with a Geant4 simulation. We determined a (34+-3) % and (38+-3) % detection efficiency for the vertical and horizontal configurations, respectively, for En = 2.4 MeV neutrons.

physics.ins-det

A Segmented Total Energy Detector (sTED) optimized for $(n,γ)$ cross-section measurements at n_TOF EAR2

The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of $4\times 10^7$ neutrons per nominal proton pulse, which is 50 times higher than the one of Experimental ARea 1 (EAR1) of $8\times10^5$ neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detectors response, by reducing the active volume per module and by using a photomultiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to $γ$-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2.

physics.ins-det

Recent highlights and prospects on (n,$γ$) measurements at the CERN n_TOF facility

Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$γ$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming the current experimental limitations for TOF measurements, in particular on low mass unstable samples, requires the combination of facilities with high instantaneous flux, such as the CERN n_TOF facility, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution presents a summary about the recent highlights in the field of (n,$γ$) measurements at n_TOF. The recent upgrades in the facility and in new detector concepts for (n,\g) measurements are described. Last, an overview is given on the existing limitations and prospects for TOF measurements involving unstable targets and the outlook for activation measurements at the brand new high-flux n_TOF-NEAR station.

nucl-ex

New detection systems for an enhanced sensitivity in key stellar (n,$γ$) measurements

Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and the high sample-related background in the case of the unstable $s$-process branching points. Measurements on neutron magic nuclei, that act as $s$-process bottlenecks, are affected by low (n,$γ$) cross sections and a dominant neutron scattering background. Overcoming these experimental challenges requires the combination of facilities with high instantaneous flux, such as n\_TOF-EAR2, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution reviews some of the latest detector developments in detection systems for (n,$γ$) measurements at n\_TOF, such as i-TED, an innovative detection system which exploits the Compton imaging technique to reduce the dominant neutron scattering background and s-TED, a highly segmented total energy detector intended for high flux facilities. The discussion will be illustrated with results of the first measurement of key the $s$-process branching-point reaction $^{79}$Se(n,$γ$).

nucl-ex

First measurement of the $^{94}$Nb($n$,$γ$) cross section at the CERN n\_TOF facility

One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution.In the particular case of the radioactive $^{94}$Nb, the $^{94}$Nb($n$,$γ$) cross-section could play a role in the determination of the $s$-process production of $^{94}$Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous $^{94}$Nb($n$,$γ$) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing high-quality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments.Motivated by this situation, a first measurement of the $^{94}$Nb($n$,$γ$) reaction was carried out at CERN n\_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality $^{94}$Nb-sample. The latter was based on hyper-pure $^{93}$Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C$_{6}$D$_{6}$ detectors and a high-resolution LaCl$_{3}$(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties.At the current status of the data analysis, 18 resonance in $^{94}$Nb+$n$ have been observed for the first time in the neutron energy range from thermal up to 10 keV.

nucl-ex

Simultaneous Gamma-Neutron Vision device: a portable and versatile tool for nuclear inspections

GN-Vision is a novel dual $γ$-ray and neutron imaging system, which aims at simultaneously obtaining information about the spatial origin of $γ$-ray and neutron sources. The proposed device is based on two position sensitive detection planes and exploits the Compton imaging technique for the imaging of $γ$-rays. In addition, spatial distributions of slow- and thermal-neutron sources ($<$100 eV) are reconstructed by using a passive neutron pin-hole collimator attached to the first detection plane. The proposed gamma-neutron imaging device could be of prime interest for nuclear safety and security applications. The two main advantages of this imaging system are its high efficiency and portability, making it well suited for nuclear applications were compactness and real-time imaging is important. This work presents the working principle and conceptual design of the GN-Vision system based on Monte Carlo simulations and explores its simultaneous $γ$-ray and neutron detection and imaging capabilities for a realistic case of a security inspection where a $^{252}$Cf source is hidden in a neutron moderating container.

physics.ins-det

First direct limit on the 334 keV resonance strength in the $^{22}$Ne(α,γ)$^{26}$Mg reaction

In stars, the fusion of $^{22}$Ne and $^4$He may produce either $^{25}$Mg, with the emission of a neutron, or $^{26}$Mg and a $γ$ ray. At high temperature, the ($α,n$) channel dominates, while at low temperature, it is energetically hampered. The rate of its competitor, the $^{22}$Ne($α$,$γ$)$^{26}$Mg reaction, and, hence, the minimum temperature for the ($α,n$) dominance, are controlled by many nuclear resonances. The strengths of these resonances have hitherto been studied only indirectly. The present work aims to directly measure the total strength of the resonance at $E$_{r}$\,=\,$334$\,$keV (corresponding to $E$_{x}$\,=\,$10949$\,$keV in $^{26}$Mg). The data reported here have been obtained using high intensity $^4$He$^+$ beam from the INFN LUNA 400 kV underground accelerator, a windowless, recirculating, 99.9% isotopically enriched $^{22}$Ne gas target, and a 4$π$ bismuth germanate summing $γ$-ray detector. The ultra-low background rate of less than 0.5 counts/day was determined using 67 days of no-beam data and 7 days of $^4$He$^+$ beam on an inert argon target. The new high-sensitivity setup allowed to determine the first direct upper limit of 4.0$\,\times\,$10$^{-11}$ eV (at 90% confidence level) for the resonance strength. Finally, the sensitivity of this setup paves the way to study further $^{22}$Ne($α$,$γ$)$^{26}$Mg resonances at higher energy.

nucl-ex

Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF

This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with $γ$-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate $i$ neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area.

nucl-ex

The $^{7}$Be(n,p)$^{7}$Li reaction and the Cosmological Lithium Problem: measurement of the cross section in a wide energy range at n_TOF (CERN)

We report on the measurement of the $^{7}$Be($n, p$)$^{7}$Li cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n_TOF facility at CERN. This reaction plays a key role in the lithium yield of the Big Bang Nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this reaction did not cover the energy window of interest for BBN, and showed a large discrepancy between each other. The measurement was performed with a Si-telescope, and a high-purity sample produced by implantation of a $^{7}$Be ion beam at the ISOLDE facility at CERN. While a significantly higher cross section is found at low-energy, relative to current evaluations, in the region of BBN interest the present results are consistent with the values inferred from the time-reversal $^{7}$Li($p, n$)$^{7}$Be reaction, thus yielding only a relatively minor improvement on the so-called Cosmological Lithium Problem (CLiP). The relevance of these results on the near-threshold neutron production in the p+$^{7}$Li reaction is also discussed.

nucl-ex

Direct measurement of the 13C(α,n)16O cross section into the s-process Gamow peak

One of the main neutron sources for the astrophysical s-process is the reaction 13C(α,n)16O, taking place in thermally pulsing Asymptotic Giant Branch stars at temperatures around 90 MK. To model the nucleosynthesis during this process the reaction cross section needs to be known in the 150-230keV energy window (Gamow peak). At these sub-Coulomb energies cross section direct measurements are severely affected by the low event rate, making us rely on input from indirect methods and extrapolations from higher-energy direct data. This leads to an uncertainty in the cross section at the relevant energies too high to reliably constrain the nuclear physics input to s-process calculations. We present the results from a new deep-underground measurement of 13C(α,n)16O, covering the energy range 230-300keV, with drastically reduced uncertainties over previous measurements and for the first time providing data directly inside the s-process Gamow peak. Selected stellar models have been computed to estimate the impact of our revised reaction rate. For stars of nearly solar composition, we find sizeable variations of some isotopes, whose production is influenced by the activation of close-by branching points that are sensitive to the neutron density, in particular the two radioactive nuclei 60Fe and 205Pb, as well as 152Gd

nucl-ex