Searcharxiv⌕ Search

arXiv subjects

J. Balibrea-Correa

Publications and source records attributed to J. Balibrea-Correa.

24 records · Page 2Linked to original sources

Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques

i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,γ$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim both $^{197}$Au($n,γ$) and $^{56}$Fe($n, γ$) reactions were measured at CERN n\_TOF using an i-TED demonstrator based on only three position-sensitive detectors. Two \cds detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of $\sim$3 higher detection sensitivity than state-of-the-art \cds detectors in the $\sim$10~keV neutron energy range of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and new analysis methodologies based on Machine-Learning techniques.

physics.ins-det↗

Machine Learning aided 3D-position reconstruction in large LaCl$_{3}$ crystals

We investigate five different models to reconstruct the 3D $γ$-ray hit coordinates in five large \lacls monolithic crystals optically coupled to pixelated silicon photomultipliers. These scintillators have a base surface of 50 $\times$ 50 mm$^2$ and five different thicknesses, from 10 mm to 30 mm. Four of these models are analytical prescriptions and one is based on a Convolutional Neural Network. Average resolutions close to 1-2mm fwhm are obtained in the transverse crystal plane for crystal thicknesses between 10 mm and 20 mm using analytical models. For thicker crystals average resolutions of about 3-5~mm fwhm are obtained. Depth of interaction resolutions between 1mm and 4 mm are achieved depending on the distance of the interaction point to the photosensor surface. We propose a Machine Learning algorithm to correct for linearity distortions and pin-cushion effects. The latter allows one to keep a large field of view of about 70-80\% of the crystal surface, regardless of crystal thickness. This work is aimed at optimizing the performance of the so-called Total Energy Detector with Compton imaging capability (i-TED) for time-of-flight neutron capture cross-section measurements.

physics.ins-det↗

A new approach to monitor 13C-targets degradation in situ for 13C(alpha,n)16O cross-section measurements at LUNA

Direct measurements of reaction cross-sections at astrophysical energies often require the use of solid targets able to withstand high ion beam currents for extended periods of time. Thus, monitoring target thickness, isotopic composition, and target stoichiometry during data taking is critical to account for possible target modifications and to reduce uncertainties in the final cross-section results. A common technique used for these purposes is the Nuclear Resonant Reaction Analysis (NRRA), which however requires that a narrow resonance be available inside the dynamic range of the accelerator used. In cases when this is not possible, as for example the 13C(alpha,n)16O reaction recently studied at low energies at the Laboratory for Underground Nuclear Astrophysics (LUNA) in Italy, alternative approaches must be found. Here, we present a new application of the shape analysis of primary gamma rays emitted by the 13C(p,g)14N radiative capture reaction. This approach was used to monitor 13C target degradation {\em in situ} during the 13C(alpha,n)16O data taking campaign. The results obtained are in agreement with evaluations subsequently performed at Atomki (Hungary) using the NRRA method. A preliminary application for the extraction of the 13C(alpha,n)16O reaction cross-section at one beam energy is also reported.

physics.ins-det↗

Review and new concepts for neutron-capture measurements of astrophysical interest

The idea of slow-neutron capture nucleosynthesis formulated in 1957 triggered a tremendous experimental effort in different laboratories worldwide to measure the relevant nuclear physics input quantities, namely ($n,γ$) cross sections over the stellar temperature range (from few eV up to several hundred keV) for most of the isotopes involved from Fe up to Bi. A brief historical review focused on total energy detectors will be presented to illustrate how, advances in instrumentation have led, over the years, to the assessment and discovery of many new aspects of $s$-process nucleosynthesis and to the progressive refinement of theoretical models of stellar evolution. A summary will be presented on current efforts to develop new detection concepts, such as the Total-Energy Detector with $γ$-ray imaging capability (i-TED). The latter is based on the simultaneous combination of Compton imaging with neutron time-of-flight (TOF) techniques, in order to achieve a superior level of sensitivity and selectivity in the measurement of stellar neutron capture rates.

physics.ins-det↗

The $^{7}$Be($\boldsymbol{n,p}$)$^{7}$Li reaction and the Cosmological Lithium Problem: measurement of the cross section in a wide energy range at n_TOF (CERN)

We report on the measurement of the $^{7}$Be($n, p$)$^{7}$Li cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n\_TOF facility at CERN. This reaction plays a key role in the lithium yield of the Big Bang Nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this reaction did not cover the energy window of interest for BBN, and showed a large discrepancy between each other. The measurement was performed with a Si-telescope, and a high-purity sample produced by implantation of a $^{7}$Be ion beam at the ISOLDE facility at CERN. While a significantly higher cross section is found at low-energy, relative to current evaluations, in the region of BBN interest the present results are consistent with the values inferred from the time-reversal $^{7}$Li($p, n$)$^{7}$Be reaction, thus yielding only a relatively minor improvement on the so-called Cosmological Lithium Problem (CLiP). The relevance of these results on the near-threshold neutron production in the p+$^{7}$Li reaction is also discussed.

nucl-ex↗

Experimental setup and procedure for the measurement of the 7Be(n,α)α reaction at n_TOF

The newly built second experimental area EAR2 of the n_TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the 7Be(n,α) reaction, which represents one of the focal points toward the solution of the cosmological Lithium abundance problem, and whose only measurement, at thermal energy, dates back to 1963. The apparently unsurmountable experimental difficulties stemming from the huge 7Be γ-activity, along with the lack of a suitable neutron beam facility, had so far prevented further measurements. The detection system is subject to considerable radiation damage, but is capable of disentangling the rare reaction signals from the very high background. This newly developed setup could likely be useful also to study other challenging reactions requiring the detectors to be installed directly in the neutron beam.

physics.ins-det↗