SearcharxivSearch

arXiv subjects

J. D. Holt

Publications and source records attributed to J. D. Holt.

At least 19 recordsLinked to original sources

Electromagnetic transition strength in $^{53}$Ca: the lifetime of the $5/2^{-}$ state

High-resolution in-beam $γ$-ray spectroscopy of $^{53}$Ca was performed at the Radioactive Isotope Beam Factory (RIBF) at RIKEN. Excited states in $^{53}$Ca were populated via one-neutron and one-proton removal reactions from a $^{55}$Sc radioactive beam, and the emitted $γ$ rays were detected using the HiCARI hybrid germanium detector array. The lifetime of the first excited $5/2^{-}$ state in $^{53}$Ca was measured for the first time through an analysis of Doppler-roadened $γ$-ray line shapes arising from relativistic recoil velocities. A lifetime of $τ = 11.3_{-11.3}^{+5.3(stat)+3(sys)}$ ps was deduced, corresponding to a reduced transition probability of $B(E2;5/2^{-}{\rightarrow}1/2^{-}) > 2.6 e^{2}fm^{4}$ at the 1$σ$ level, with a best-fit value of $4.5 e^{2}fm^{4}$. The measured transition strength is compared with state-of-the-art shell-model and ab initio calculations, providing a stringent benchmark for shell-model Hamiltonians and effective charges and modern ab initio descriptions of the neutron-rich calcium isotopes approaching the potential $N$ = 40 shell closure.

nucl-ex

Characterization of CRYO ASIC for charge readout in the nEXO experiment

nEXO is a proposed next-generation experiment searching for the neutrinoless double beta decay of $^{136}$Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC). To image the ionization signals from events in the liquid xenon, the detector will employ metallized fused-silica charge collection tiles instrumented with cryogenic application-specific integrated circuits (ASICs), referred to as CRYO ASIC, which are designed to operate directly in LXe to minimize input capacitance and pick-up noise. Here we present the performance of the CRYO ASIC mounted on an auxiliary printed circuit board and evaluated both in a cryogenic environmental chamber and in a dedicated LXe test stand. We demonstrate that the ASICs achieve the desired performance at liquid xenon temperatures, showing a gain stability better than 0.2% over 24-hour operation and reliable in-situ calibration using an on-chip pulser. In the LXe test stand, we show that boiling caused by the chip heat dissipation can be mitigated by operating the system above ~0.1 MPa. The in-LXe noise measured agrees with simulation, which indicates it the $150~e^-$ design requirement can be satisfied. These results establish CRYO ASIC as a viable low-noise in-LXe charge readout solution for nEXO.

physics.ins-det

Ab initio short-range nuclear matrix elements for neutrinoless double-beta decay

We present converged ab initio calculations of short-range neutrinoless double-beta ($0νββ$) decay nuclear matrix elements for the key experimental isotopes $^{76}$Ge, $^{82}$Se, $^{130}$Te and $^{136}$Xe. Starting from different nuclear forces derived from chiral effective field theory, we apply the in-medium similarity renormalization group to obtain an effective valence-space Hamiltonian along with consistently transformed $0νββ$-decay operators. We then obtain a range of values for the matrix elements that is consistent with, but generally smaller than, those from phenomenology. Finally, we combine our results with current limits from $0νββ$-decay searches to obtain constraints for the sterile-neutrino mixing-mass parameter space when considering the inclusion of a fourth, sterile neutrino.

nucl-th

Global Ab initio Neutrino Mass Limits from Neutrinoless Double-Beta Decay

We present global limits for Majorana neutrino masses by combining latest results from neutrinoless double-beta ($0νββ$) decay searches and ab initio nuclear theory. Limits are derived in a Bayesian framework utilizing likelihood functions from a suite of $0νββ$-decay experiments in conjunction with nuclear matrix elements calculated from nuclear and electroweak forces derived from chiral effective field theory and implemented in the in-medium similarity renormalization group many-body approach. In contrast to nuclear models, ab initio results indicate that the current generation of $0νββ$-decay experiments have likely \textit{not} yet reached sensitivities required to probe the mass regime allowed by neutrino-oscillation data, where the combined bounds are notably stronger than those given by individual experiments. Finally, from predicted sensitivities of next-generation searches, we show that, while no one individual experiment fully covers the inverted mass ordering, this can be achieved from combined contributions from the four key isotopes: $^{76}$Ge, $^{100}$Mo, $^{130}$Te, and $^{136}$Xe.

nucl-th

Ab initio calculation of symmetry-breaking observables

Symmetry-violating observables such as the nuclear anapole and Schiff moments provide sensitive probes of the fundamental symmetries of nature and physics beyond the Standard Model. Their interpretation has been hindered, however, by the lack of ab initio nuclear structure calculations in the medium-mass and heavy nuclei of interest to experimentalists. To provide them, we introduce a new version of the in-medium similarity renormalization group (IMSRG) designed to target parity-violating operators. By generalizing the IMSRG flow equations to evolve the weak symmetry-breaking Hamiltonian - and the anapole or Schiff operators - alongside the strong nuclear Hamiltonian, we construct a systematically improvable framework for computing these parity-violating moments. We benchmark the method against the no-core shell model in light nuclei and obtain the first ab initio predictions of the anapole moment in $^{29}$Si and the Schiff moments in $^{129}$Xe. These heavier systems are of direct experimental interest.

nucl-th

Constraining the trend of the $N = 50$ shell gap towards $^{100}$Sn with the masses of $^{96-98}$Cd

We present the first determination of the $N = 50$ empirical shell gap at $Z = 48$ by precise mass measurements of the neutron-deficient cadmium isotopes $^{96-98}$Cd with the ISOLTRAP mass spectrometer at ISOLDE-CERN, including the first precise determination of the excitation energy of the $25/2^+$ isomer in $^{97}$Cd. Through the systematics of Coulomb Displacement Energies, we further deduce the empirical shell gap in the higher-$Z$ isotopic chains, tightly constraining the $^{100}$Sn mass-surface region. The new experimental data suggest an enhancement of the gap towards $^{100}$Sn, which is discussed in comparison to state-of-the-art calculations using energy-density functional and new ab initio approaches.

nucl-ex

The nEXO Radioassay Program

Material radioactivity compilations, such as the one presented here, are important enablers of science. They are useful for the selection of radiopure materials used in the design and construction of low-energy rare-event search experiments. They allow researchers developing such experiments to save time on material studies and avoid costly duplication of effort. The data presented here were generated in support of the planned nEXO double-beta decay search. This work contains among the most restrictive constraints on the natural radioactivity content of materials of general interest to the low-radioactivity community, found in any tabulation of this kind. In this study, various techniques were employed; they are described here.

physics.ins-det

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This paper addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

physics.ins-det

Charge Radii Measurements of Exotic Tin Isotopes in the Proximity of $N=50$ and $N=82$

We report nuclear charge radii for the isotopes $^{104-134}$Sn, measured using two different collinear laser spectroscopy techniques at ISOLDE-CERN. These measurements clarify the arch-like trend in charge radii along the isotopic chain and reveal an odd-even staggering that is more pronounced near the $N=50$ and $N=82$ shell closures. The observed local trends are well described by both nuclear density functional theory and valence space in-medium similarity renormalization group calculations. Both theories predict appreciable contributions from beyond-mean-field correlations to the charge radii of the neutron-deficient tin isotopes. The models, however, fall short of reproducing the magnitude of the known $B(E2)$ transition probabilities, highlighting the remaining challenges in achieving a unified description of both ground-state properties and collective phenomena.

nucl-ex

Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments

The next generation of rare-event search experiments in nuclear and particle physics demand structural materials combining exceptional mechanical strength with ultra-low levels of radioactive contamination. This study evaluates chemical vapor deposition (CVD) nickel as a candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates underwent tensile testing before and after welding alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, welding and heat treatment were found to reduce the tensile strength to levels comparable to standard Ni, with observed porosity in the welds likely contributing to this reduction. Material assay via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution produced measured bulk concentration of 232-Th, 238-U, and nat-K at the levels of ~70 ppq, <100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 micrometer beneath the surface, likely associated with the aluminum growth substrate. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in welding and surface cleaning techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

nucl-ex

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $μ$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

physics.ins-det

Sensitivity of nEXO to $^{136}$Xe Charged-Current Interactions: Background-free Searches for Solar Neutrinos and Fermionic Dark Matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, $ν_e + ^{136}$Xe$\rightarrow ^{136}$Cs$^* + e^-$, as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of $^{136}$Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of $10^{-9}$, enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of CNO solar neutrinos with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement towards addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the $^7$Be neutrinos with a precision of $σ\leq 1.5$ keV and could determine the survival probability of $^{7}$Be and $pep$ solar $ν_e$ with precision comparable to state-of-the-art. These quantities are sensitive to the Sun's core temperature and to non-standard neutrino interactions, respectively. Furthermore, the strong background suppression would allow nEXO to search for for charged-current interactions of fermionic dark matter in the mass range $m_χ$ = $0.668$-$7$ MeV with a sensitivity up to three orders of magnitude better than current limits.

nucl-ex

Universal Effective Charges in the $sd$ and $fp$ Shells

The 247-keV state in $^{54}$Sc, populated in the $β$ decay of $^{54}$Ca, is reported here as a nanosecond isomer with a half-life of 26.0(22) ns. The state is interpreted as the $1^+$ member of the $πf_{7/2}\otimesνf_{5/2}$ spin-coupled multiplet, which decays to the $3^+,πf_{7/2} \otimes νp_{1/2}$ ground state. The new half-life corresponds to a pure $E2$ transition with a strength of 1.93(16) W.u., providing the most precise, unambiguous $B(E2)$ value in the neutron-rich $fp$ region to date for a nucleus with valence protons above $Z=20$. Notably, it is roughly four times larger than the $B(E2; 1/2^{-} \rightarrow 5/2^{-})$ value in $^{55}$Ca. The results, as compared to semi-empirical and ab initio shell-model calculations, indicate (1) a weak $N=34$ sub-shell gap relative to $N = 32$, (2) a large $E2$ enhancement in Sc as compared to Ca due to $1p-1h$ proton excitations across $Z=28$, and (3) empirical effective proton and neutron charges, $e_π$ = 1.30(8)$e$ and $e_ν$ = 0.452(7)$e$, respectively, that are in contrast to reports of $e_π\approx 1.1-1.15e$ and $e_ν\approx 0.6-0.8e$ for $fp$-shell nuclei near $N = Z$. We demonstrate that these reports are erroneous and that, in fact, a universal set of effective charges can be used across the $sd$ and $fp$ shells.

nucl-ex

Reduction in nuclear size and quadrupole deformation of high-spin isomers of 127,129In

We employed laser spectroscopy of atomic transitions to measure the nuclear charge radii and electromagnetic properties of the high-spin isomeric states in neutron-rich indium isotopes (Z = 49) near the closed proton and neutron shells at Z = 50 and N = 82. Our data reveal a reduction in the nuclear charge radius and intrinsic quadrupole moment when protons and neutrons are fully aligned in 129In(N = 80), to form the high spin isomer. Such a reduction is not observed in 127In(N = 78), where more complex configurations can be formed by the existence of four neutron-holes. These observations are not consistently described by nuclear theory.

nucl-ex

Charge radii of neutron-rich scandium isotopes and the seniority symmetry in the $0f_{7/2}$ shell

Nuclear charge radii of neutron-rich $^{47-49}$Sc isotopes were measured using collinear laser spectroscopy at CERN-ISOLDE. The new data reveal that the charge radii of scandium isotopes exhibit a distinct trend between $N=20$ and $N=28$, with $^{41}$Sc and $^{49}$Sc isotopes having similar values, mirroring the closeness of the charge radii of $^{40}$Ca and $^{48}$Ca. Theoretical models that successfully interpret the radii of calcium isotopes could not account for the observed behavior in scandium radii, in particular the reduced odd-even staggering. Remarkably, the inclusion of the new $^{49}$Sc radius data has unveiled a similar trend in the charge radii of $N=28$ isotones and $Z=20$ isotopes when adding the neutrons atop the $^{40}$Ca core and the protons atop the $^{48}$Ca core, respectively. We demonstrate that this trend is consistent with the prediction of the seniority model.

nucl-ex

Exploring the Onset of Collectivity Approaching N=40 through Manganese Masses

Isotopes in the region of the nuclear chart below $^{68}\mathrm{Ni}$ have been the subject of intense experimental and theoretical effort due to the potential onset of a new ``island of inversion'' when crossing the harmonic oscillator subshell closure at $N = 40$. We have measured the masses of $^{64-68}\textrm{Mn}$ using TITAN's multiple-reflection time-of-flight mass spectrometer, resulting in the first precision mass measurements of $^{67}\mathrm{Mn}$ and $^{68}\mathrm{Mn}$. These results are compared to \textit{ab initio} calculations and modern shell model calculations and show an increase in collectivity approaching $N=40$.

nucl-ex

Refined topology of the N = 20 island of inversion with high precision mass measurements of $^{31-33}$Na and $^{31-35}$Mg

Mass measurements of $^{31-33}$Na and $^{31-35}$Mg using the TITAN MR-TOF-MS at TRIUMF's ISAC facility are presented, with the uncertainty of the $^{33}$Na mass reduced by over two orders of magnitude. The excellent performance of the MR-TOF-MS has also allowed the discovery of a millisecond isomer in $^{32}$Na. The precision obtained shows that the binding energy of the normally closed N = 20 neutron shell reaches a minimum for $^{32}$Mg but increases significantly for $^{31}$Na, hinting at the possibility of enhanced shell strength toward the unbound $^{28}$O. We compare the results with new ab initio predictions that raise intriguing questions of nuclear structure beyond the dripline.

nucl-ex

Precision mass measurements of $^{74-76}$Sr using TITAN's Multiple-Reflection Time-of-Flight Mass Spectrometer

We report precision mass measurements of $^{74-76}$Sr performed with the TITAN Multiple-Reflection Time-of-Flight Mass Spectrometer. This marks a first time mass measurement of $^{74}$Sr and gives increased mass precision to both $^{75}$Sr and $^{76}$Sr which were previously measured using storage ring and Penning trap methods, respectively. This completes the A = 74, T = 1 isospin triplet and gives increased precision to the A = 75, T = 1/2 isospin doublet which are both the heaviest experimentally evaluated triplets and doublets to date. The new data allow us to evaluate coefficients of the isobaric multiplet mass equation for the first time at A = 74, and with increased precision at A = 75. With increased precision of 75Sr, we confirm the recent measurement reported by CSRe which was used to remove a staggering anomaly in the doublets. New ab initio valence-space in-medium similarity renormalization group calculations of the T = 1 triplet are presented at A = 74. We also investigate the impact of the new mass data on the reaction flow of the rapid proton capture process in type I x-ray bursts using a single-zone model.

nucl-ex