Characterization of CRYO ASIC for charge readout in the nEXO experiment

Abstract

nEXO is a proposed next-generation experiment searching for the neutrinoless double beta decay of $^{136}$Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC). To image the ionization signals from events in the liquid xenon, the detector will employ metallized fused-silica charge collection tiles instrumented with cryogenic application-specific integrated circuits (ASICs), referred to as CRYO ASIC, which are designed to operate directly in LXe to minimize input capacitance and pick-up noise. Here we present the performance of the CRYO ASIC mounted on an auxiliary printed circuit board and evaluated both in a cryogenic environmental chamber and in a dedicated LXe test stand. We demonstrate that the ASICs achieve the desired performance at liquid xenon temperatures, showing a gain stability better than 0.2% over 24-hour operation and reliable in-situ calibration using an on-chip pulser. In the LXe test stand, we show that boiling caused by the chip heat dissipation can be mitigated by operating the system above ~0.1 MPa. The in-LXe noise measured agrees with simulation, which indicates it the $150~e^-$ design requirement can be satisfied. These results establish CRYO ASIC as a viable low-noise in-LXe charge readout solution for nEXO.

Explore related subjects

Keep this discovery

BibTeXRIS

Z. Li, M. Yu, E. Angelico, A. Atencio, A. Gupta, P. Knauss, A. Pena-Perez, B. G. Lenardo, P. Acharya, A. Amy, A. Anker, I. J. Arnquist, J. Bane, V. Belov, T. Bhatta, A. Bolotnikov, J. Breslin, P. A. Breur, J. P. Brodsky, E. Brown, T. Brunner, B. Burnell, E. Caden, G. F. Cao, L. Q. Cao, D. Cesmecioglu, D. Chernyak, M. Chiu, R. Collister, M. Marquis, T. Daniels, L. Darroch, R. DeVoe, M. L. di Vacri, X. Defay, Y. Y. Ding, D. Doering, M. J. Dolinski, A. Dragone, B. Eckert, A. Emara, N. Fatemighomi, W. Fairbank, B. T. Foust, D. Gallacher, N. Gallice, A. Gaur, W. Gillis, F. Girard, A. Gorham, K. Gracequist, G. Gratta, C. A. Hardy, J. Hasi, S. Hedges, M. Heffner, E. Hein, H. Hernandez Herrera, J. D. Holt, A. Iverson, X. S. Jiang, A. Karelin, D. Keblbeck, C. Kenney, I. Kotov, A. Kuchenkov, K. S. Kumar, S. Lavoie, A. Larson, M. B. Latif, K. G. Leach, D. S. Leonard, G. Lessard, K. K. H. Leung, G. Li, X. Li, C. Licciardi, R. Lindsay, R. MacLellan, S. Majidi, C. Malbrunot, B. Markovic, J. Masbou, M. Medina-Peregrina, S. Mngonyama, B. Mong, D. C. Moore, K. Ni, I. Nitu, A. Nolan, S. C. Nowicki, J. C. Nzobadila Ondze, A. Odian, J. L. Orrell, G. S. Ortega, L. Pagani, H. Peltz Smalley, A. Piepke, A. Pocar, S. Prentice. 2025-12-11. Characterization of CRYO ASIC for charge readout in the nEXO experiment. https://arxiv.org/abs/2512.11116

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det