Evaluation of Performance of the p-stop fabrication process variations in ATLAS18 strip sensors, Pre- and Post-Irradiation

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). Radiation-hard n-in-p micro-strip sensors were developed for use in the ITk. During quality control (QC) and quality assurance (QA) procedures performed on ATLAS18 production sensors and test chips, ATLAS ITk strip sensor institutes identified instances of low p-stop density in certain production batches. To investigate the origin of these issues and to try some technological improvements, two dedicated sample batches with four variations of the p-stop fabrication process were produced. These process types (1-4) were systematically evaluated to determine their effectiveness and uniformity. In total, 56 full-size sensors, along with numerous miniature sensors and test chips, were tested. A number of samples were used in the irradiation campaign reaching the maximum expected levels for the HL-LHC operation after 10 years - with neutrons up to 1.6E15 neq/cm2, and with gamma rays from a 60Co source up to 66 Mrad. The goal of this evaluation program is to assess the impact of of p-stop fabrication process variations on interstrip isolation performance and to provide feedback for future sensor development. This paper describes the applied test procedures and presents the corresponding results, which demonstrate good sensor performance for all investigated p-stop types. The findings confirm the reliability of the evaluated designs and identify specific advantages that can inform further optimization of strip sensor fabrication.

physics.ins-det↗

Summary of quality control (QC) of ATLAS18 production ITk strip sensors

To address the demanding operational requirements of the High-Luminosity upgrade of the Large Hadron Collider (HL-LHC), the ATLAS experiment is replacing its current Inner Detector with a new all-silicon Inner Tracker (ITk). The ITk will feature an active area of 165 m2, with its outer tracking layers populated by approximately 18,000 ATLAS18 n+-in-p silicon strip sensors. The silicon sensors, available in eight geometries tailored to two barrel and six endcap types, respectively, are designed to tolerate fluences of up to 1.6 x 10^15 neq/cm2 and ionizing doses of 66 Mrad. A comprehensive, multi-year Quality Control (QC) program is underway across multiple international institutes to evaluate these ITk strip sensors for mechanical and electrical conformity. The QC process includes IV/CV characterization, full strip tests, long-term current stability monitoring, visual inspection, and metrology tests. To manage the high throughput of about 500 sensors per month, the collaboration has implemented standardized test procedures, software packages for data monitoring and integrity checks, unified data formats, and automated analysis tools. The standardization ensures consistent pass/fail evaluation and centralized data handling that enables effective identification of trends and anomalies at all sites during the production. This contribution presents an overview of the ITk strip sensor production and QC framework, along with key findings throughout the whole production, such as charge-up of sensors, stability of the leakage currents, nonrecoverable IV breakdown, and low inter-strip isolation within wafers. It provides insights into sensor yield, quality trends, and reviews specific case studies, such as p-stop doping non-uniformity. Over 91% of the production, totaling over 590 batches, were tested and accepted. Six batches were rejected. These account for 2.8% of the total tested sensors.

physics.ins-det↗