Searcharxiv⌕ Search

arXiv subjects

J. Dilling

Publications and source records attributed to J. Dilling.

82 records · Page 5Linked to original sources

First direct mass-measurement of the two-neutron halo nucleus 6He and improved mass for the four-neutron halo 8He

The first direct mass-measurement of $^{6}$He has been performed with the TITAN Penning trap mass spectrometer at the ISAC facility. In addition, the mass of $^{8}$He was determined with improved precision over our previous measurement. The obtained masses are $m$($^{6}$He) = 6.018 885 883(57) u and $m$($^{8}$He) = 8.033 934 44(11) u. The $^{6}$He value shows a deviation from the literature of 4$σ$. With these new mass values and the previously measured atomic isotope shifts we obtain charge radii of 2.060(8) fm and 1.959(16) fm for $^{6}$He and $^{8}$He respectively. We present a detailed comparison to nuclear theory for $^6$He, including new hyperspherical harmonics results. A correlation plot of the point-proton radius with the two-neutron separation energy demonstrates clearly the importance of three-nucleon forces.

nucl-ex↗

Verifying the accuracy of the TITAN Penning-trap mass spectrometer

TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) is an online facility designed to carry out high-precision mass measurements on singly and highly charged radioactive ions. The TITAN Penning trap has been built and optimized in order to perform such measurements with an accuracy in the sub ppb-range. A detailed characterization of the TITAN Penning trap is presented and a new compensation method is derived and demonstrated, verifying the performance in the range of sub-ppb.

physics.ins-det↗

First experimental determination of the charge radius of $^{74}$Rb and its application in tests of the unitarity of the CKM matrix

Collinear-laser spectroscopy with bunched-beams technique was used for the study of neutron deficient Rb isotopes, out to $^{74}$Rb ($N=Z=37$) at TRIUMF. The measured hyperfine coupling constants of $^{76,78m}$Rb were in agreement with literature values. The nuclear spin of $^{75}$Rb was confirmed to be $I=3/2$, and its hyperfine coupling constants were measured for the first time. The mean-square charge radius of $^{74}$Rb was determined for the first time. This result has improved the isospin symmetry breaking correction term used to calculate the $\mathcal{F}t$ value, with implications for tests of the unitarity of the Cabibbo-Kobayashi-Maskawa matrix.

nucl-ex↗

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

nucl-ex↗

A large Bradbury Nielsen ion gate with flexible wire spacing based on photo-etched stainless steel grids and its characterization applying symmetric and asymmetric potentials

Bradbury Nielsen gates are well known devices used to switch ion beams and are typically applied in mass or mobility spectrometers for separating beam constituents by their different flight or drift times. A Bradbury Nielsen gate consists of two interleaved sets of electrodes. If two voltages of the same amplitude but opposite polarity are applied the gate is closed, and for identical (zero) potential the gate is open. Whereas former realizations of the device employ actual wires resulting in difficulties with winding, fixing and tensioning them, our approach is to use two grids photo-etched from a metallic foil. This design allows for simplified construction of gates covering large beam sizes up to at least 900\,mm$^2$ with variable wire spacing down to 250\,\textmu m. By changing the grids the wire spacing can be varied easily. A gate of this design was installed and systematically tested at TRIUMF's ion trap facility, TITAN, for use with radioactive beams to separate ions with different mass-to-charge ratios by their time-of-flight.

physics.ins-det↗

Isotope Shift Measurements of Stable and Short-Lived Lithium Isotopes for Nuclear Charge Radii Determination

Changes in the mean-square nuclear charge radii along the lithium isotopic chain were determined using a combination of precise isotope shift measurements and theoretical atomic structure calculations. Nuclear charge radii of light elements are of high interest due to the appearance of the nuclear halo phenomenon in this region of the nuclear chart. During the past years we have developed a new laser spectroscopic approach to determine the charge radii of lithium isotopes which combines high sensitivity, speed, and accuracy to measure the extremely small field shift of an 8 ms lifetime isotope with production rates on the order of only 10,000 atoms/s. The method was applied to all bound isotopes of lithium including the two-neutron halo isotope Li-11 at the on-line isotope separators at GSI, Darmstadt, Germany and at TRIUMF, Vancouver, Canada. We describe the laser spectroscopic method in detail, present updated and improved values from theory and experiment, and discuss the results.

physics.atom-ph↗

First Penning-trap mass measurement in the millisecond half-life range: the exotic halo nucleus 11Li

In this letter, we report a new mass for $^{11}$Li using the trapping experiment TITAN at TRIUMF's ISAC facility. This is by far the shortest-lived nuclide, $t_{1/2} = 8.8 \rm{ms}$, for which a mass measurement has ever been performed with a Penning trap. Combined with our mass measurements of $^{8,9}$Li we derive a new two-neutron separation energy of 369.15(65) keV: a factor of seven more precise than the best previous value. This new value is a critical ingredient for the determination of the halo charge radius from isotope-shift measurements. We also report results from state-of-the-art atomic-physics calculations using the new mass and extract a new charge radius for $^{11}$Li. This result is a remarkable confluence of nuclear and atomic physics.

nucl-ex↗

Nuclear Charge Radius of Li-9, Li-11: Halo Neutron: the influence of Halo Neutrons

The nuclear charge radius of Li-11 has been determined for the first time by high precision laser spectroscopy. On-line measurements at TRIUMF-ISAC yielded a Li-7 - Li-11 isotope shift (IS) of 25101.23(13) MHz for the Doppler-free 2s - 3s transition. IS precision for all other bound Li isotopes was also improved. Differences from calculated mass-based IS yield values for change in charge radius along the isotope chain. The charge radius decreases monotonically from Li-6 to Li-9, and then increases from 2.217(35) fm to 2.467(37) fm for Li-11. This is compared to various models, and it is found that a combination of halo neutron correlation and intrinsic core excitation best reproduces the experimental results.

physics.atom-ph↗

Scalar interaction limits from the beta-neutrino correlation of trapped radioactive atoms

We have set limits on contributions of scalar interactions to nuclear beta decay. A magneto-optical trap (MOT) provides a localized source of atoms suspended in space, so the low-energy recoiling nuclei can freely escape and be detected in coincidence with the beta. This allows reconstruction of the neutrino momentum, and the measurement of the beta-neutrino correlation, in a more direct fashion than previously possible. The beta-neutrino correlation parameter of the 0+ to 0+ pure Fermi decay of 38mK is $\tilde{a}$=0.9981+-0.0030+-0.0037, consistent with the standard model prediction a=1.

nucl-ex↗

A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams

An ion beam cooler and buncher has been developed for the manipulation of radioactive ion beams. The gas-filled linear radiofrequency ion trap system is installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its purpose is to accumulate the 60-keV continuous ISOLDE ion beam with high efficiency and to convert it into low-energy low-emittance ion pulses. The efficiency was found to exceed 10% in agreement with simulations. A more than 10-fold reduction of the ISOLDE beam emittance can be achieved. The system has been used successfully for first on-line experiments. Its principle, setup and performance will be discussed.

nucl-ex↗